Skip to main content

Modeling and Simulation of the Human Rye and Its Correlation Between Increased Intraocular Pressure and the Thickness of the Cornea

  • Conference paper
  • First Online:
  • 949 Accesses

Part of the book series: Advances in Intelligent Systems and Computing ((AISC,volume 1205))

Abstract

This work consists in the mathematical analysis, to establish a correlation between the increase of the intraocular pressure and the central thickness of the cornea, our database was acquired from both sick and healthy patients of the “Santa Lucia” clinic from the city of Quito, which complied with some rules of inclusion and exclusion that are presented later, this database was segmented based on false positives and false negatives, this was done to handle our data in a reduced way. After applying different types of interpolation, we obtained an equation that relates both to the intraocular pressure and the central thickness of the cornea, then analyzed the behavior of the equation against different types of data, both sick people and healthy people. The results obtained were encouraging, since with the identification of glaucoma at an early stage, the number of people who can lose their sight permanently will be reduced.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   189.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   249.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Sales Sanz, M.: Influencia de la córnea en la medida de la presion intraocular con distintos distemas tonométricos (2010)

    Google Scholar 

  2. Montañés, J., Gozalvo, A.S., Farriol, E.B.: Córnea y glaucoma diagnóstico y tratamiento del glaucoma de ángulo abierto (2013)

    Google Scholar 

  3. Jimenez Rodríguez, E., Lopez de Cobos, M., Luque Aranda, R., López Egea Bueno, M., Vázquez Salvi, A., García Campos, J.: Correlación entre grosor corneal central, presión intraocular y afectación glaucomatosa del campo visual. Sociedad Española de Oftalmología, España (2009)

    Google Scholar 

  4. Celi, A., Domínguez, A.: Incidencia de la Inserción Laboral en la calidad de vida de las personas con Capacidades Especiales que Laboran en el Sector Empresarial del Norte de la Ciudad de Guayaquil. Universidad Politécnica Salesiana, Guayaquil (2014)

    Google Scholar 

  5. Morales Romero, J.D.: Diseño de prótesis ocular electrónica. Universidad de San Carlos de Guatemala, Guatemala, Mayo 2009

    Google Scholar 

  6. Kanski, J.: Oftalmología Clínica 7ma ed. SA, Elsevier España (2012)

    Google Scholar 

  7. García Sánchez, J., Arias Puente, A., García Feijo, J.: Nueva estrategia terapéutica antiglaucomatosa. Jarpyo Editores, Madrid

    Google Scholar 

  8. Schiøtz, H.: Tonometry. Br. J. Ophthalmol.

    Google Scholar 

  9. Spalton, D.J., Hitchings, R.A., Hunter, P.A.: Atlas de Oftalmología clínica. Ediciones Harcourt S.A., Madrid (2004)

    Google Scholar 

  10. Fawcett, D.W.: Tratado de histología. Interamericana, División de McGraw-Hill, Madrid

    Google Scholar 

  11. Doughty, M.J., Zaman, M.L.: Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv. Ophthalmol.

    Google Scholar 

  12. Martínez de la casa, J.M., García Feijo, J., Vico, E., Fernandez Vidal, A., Benitez del Castillo, J.M., Wasfi, M., García Sanchez, J.: Effect of corneal thickness on dynamic contour, rebound, and Goldmann tonometry. Ophthalmology

    Google Scholar 

  13. Wu, R.Y., Zheng, Y.F., Wong, T.Y.: Relationship of central corneal thickness with optic disc parameters: the Singapore Malay eye study. Invest Ophthalmol. Vis. Sci. (2011)

    Google Scholar 

  14. Leske, M.C., Wu, S.Y., Hennis, A.: Risk factors for incident open-angle glaucoma: the Barbados eye studies. Ophthalmology (2008)

    Google Scholar 

  15. Singh, R.P., Goldberg, I., Graham, S., Sharma, A., Mohsin, M.: Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension. J. Glaucoma (2001)

    Google Scholar 

  16. Wang, S.Y., Melles, R., Lin, S.C.: The impact of central corneal thickness on the risk for glaucoma in a large multiethnic population. J. Glaucoma (2001)

    Google Scholar 

  17. La Rosa, F.A., Gross, R.L., Orengo Nania, S.: Central corneal thickness measurements in patients with normal tension glaucoma, primary open glaucoma, pseudiexfoliation glaucoma or ocular hypertension. Br. J. Ophthalmol. (2001)

    Google Scholar 

  18. Ventura, A.C., Bonke, M., Mojon, D.S.: Central corneal thickness measurements in patients with normal tension glaucoma, primary open glaucoma, Pseudoexfoliation glaucoma or ocular hypertension. Br. J. Ophthalmol. (2001)

    Google Scholar 

  19. Tai, L.Y., Khaw, K.W., Ng, C.M., Subrayan, V.: Central corneal thickness measurements with different imaging devices and ultrasound pachymetry. Corneal (2013)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Eduardo Pinos-Vélez .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 The Editor(s) (if applicable) and The Author(s), under exclusive license to Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Pinos-Vélez, E., Cabrera, A., Curay, A., Chacón, C.L., Ipanaqué, W., Serpa-Andrade, L. (2020). Modeling and Simulation of the Human Rye and Its Correlation Between Increased Intraocular Pressure and the Thickness of the Cornea. In: Kalra, J., Lightner, N. (eds) Advances in Human Factors and Ergonomics in Healthcare and Medical Devices. AHFE 2020. Advances in Intelligent Systems and Computing, vol 1205. Springer, Cham. https://doi.org/10.1007/978-3-030-50838-8_12

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-50838-8_12

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-50837-1

  • Online ISBN: 978-3-030-50838-8

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics