Precast prestressed concrete (PCaPC) moment-resisting frames have been applied to building constructions over 60 years in Japan. A concern recently arises about the serviceability and the seismic capacity of such existing building structures, which have often been hit by earthquakes or exposed to severe corrosion-prone environment. In this research, the former City Hall of Nandan Town in Awaji Island has been selected as a case study, which was built in 1957 as the first Japanese building using PCaPC beams. Because of its close location to the coast, the target building is considered to be exposed to a severe environment. Moreover, it was severely shaken by the Kobe earthquake in 1995, although noticeable damage was not reported by an inspection carried out several months after the earthquake. Since then several moderate earthquakes have hit it. This paper introduces the building, and describes the results of field inspection, corrosion and strength test results on concrete samples taken from the building. Seismic capacity of the building was evaluated according to the Guideline for Seismic Evaluation and Retrofit for Existing Buildings published by The Japan Building Disaster Prevention Association (JBDPA). The load carrying capacities of the beams are estimated based on the design equations for new constructions specified in the codes and guidelines published by Architectural Institute of Japan or AIJ.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
ACI (American Concrete Institute): Guide to Durable Concrete Reported by ACI Committee 201. ACI Committee 201, 53 (2008)
Bruce, S.M., McCarten, P.S.: Deterioration of prestressed concrete bridge beams in New Zealand. In: Austroads Bridge Conference, Paper No. 38 (2006)
BS EN 1992-1-1: Eurocode 2: Design of concrete structures - Part 1-1: General rules and rules for buildings. vol. 1, p. 230. British Standards Institution (2004)
GBRC (General Building Research Corporation): Seismic Diagnosis Survey Report of Nandan Town Office Building. GBRC. Osaka, Japan (1995)
JBDPA (Japan Building Disaster Prevention Association): Technical Manual for Seismic Evaluation of Existing Reinforced Concrete Buildings. JBDPA, Tokyo, Japan (2001)
JMA (Japan Meteorological Agency): Past weather data of Awaji Minami, Hyogo Prefecture, Japan (2016a). http://www.data.jma.go.jp/obd/stats/etrn/index.php?prec_no=63&block_no=1337&year=2016&month=&day=&view=. Accessed 15 Nov 2016
JMA: Seismic Intensity Data of Awaji Minami, Hyogo Prefecture, Japan (2016b). http://www.data.jma.go.jp/svd/eqdb/data/shindo/index.php. Accessed 15 Nov 2016
JSCE (Japan Society Civil Engineering): Standard Specifications for Concrete Structures. JSCE, Tokyo (2007)
Li, F., Yuan, Y., Li, C.Q.: Corrosion propagation of prestressing steel strands in concrete subject to chloride attack. Constr. Build. Mater. 25(10), 3878–3885 (2011)
Lollini, F., Redaelli, E., Bertolini, L.: Corrosion assessment of reinforced concrete elements of Torre Velasca in Milan. Case Studies in Construction Materials 4, 55–61 (2016)
Meldrum, J., Gupta, A., Mcdonald, B.: Investigation of structural damage in a corrosive environment: a case study. In: Proceedings of the Fifth International Conference on Case Histories in Geotechnical Engineering, Paper No. 19 (2004)
Ohta, T., Sakai, K., Obi, M., Ono, S.: Deterioration in a rehabilitated prestressed concrete bridge. ACI Mater. J. 89(4), 328–336 (1992)
Acknowledgement
The authors would like to thank Japan Concrete Institute (JCI), Ministry of Higher Education, Malaysia (MoHE) and University Teknologi MARA (UiTM) for the financial support and Minami-Awaji City council, CONSTECH and GBRC team for collaboration and cooperation.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG
About this paper
Cite this paper
Kamaruddin, N., Watase, C., Raouffard, M.M., Bedriñana, L.A., Zhang, K., Nishiyama, M. (2018). Durability and Seismic Resistance of an Aged Precast Prestressed Concrete Building Based on Field Inspections and Laboratory Testing. In: Hordijk, D., Luković, M. (eds) High Tech Concrete: Where Technology and Engineering Meet. Springer, Cham. https://doi.org/10.1007/978-3-319-59471-2_257
Download citation
DOI: https://doi.org/10.1007/978-3-319-59471-2_257
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-59470-5
Online ISBN: 978-3-319-59471-2
eBook Packages: EngineeringEngineering (R0)