Skip to main content

In vivo 1H-MRS of the rat brain with a clinical 3 T whole-body MR Scanner: Estimation of absolute metabolic concentrations and T2 values

  • Conference paper
World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany

Part of the book series: IFMBE Proceedings ((IFMBE,volume 25/2))

  • 100 Accesses

Abstract

In vivo single voxel 1H-MR measurements were performed in a rat’s brain on a clinical whole-body 3 T MR scanner by using a dedicated small animal head RF-coil. Spectroscopic experiments were performed with and without water suppression as well as with different echo times (TE) by placing a 0.5 ml voxel in the rat cerebrum. Absolute concentrations of tNAA, tCr, tCho, mIns, Lac and Glu were estimated by applying the internal tissue water reference technique. In addition, T2 values for tNAA, tCr and tCho were determined by mono-exponential fitting of metabolite intensities sampled at the different echo times.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 International Federation for Medical and Biological Engineering

About this paper

Cite this paper

Gussew, A., Rzanny, R., Herrmann, K.H., Schmidt, S., Witte, O.W., Reichenbach, J.R. (2009). In vivo 1H-MRS of the rat brain with a clinical 3 T whole-body MR Scanner: Estimation of absolute metabolic concentrations and T2 values. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/2. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03879-2_140

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03879-2_140

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03878-5

  • Online ISBN: 978-3-642-03879-2

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics