The purpose of this study was to assess the performance of a new motion correction algorithm. Twenty-five dynamic MR mammography (MRM) data sets and 25 contrast-enhanced three-dimensional peripheral MR angiographic (MRA) data sets which were affected by patient motion of varying severeness were selected retrospectively from routine examinations. Anonymized data were registered by a new experimental elastic motion correction algorithm. The algorithm works by computing a similarity measure for the two volumes that takes into account expected signal changes due to the presence of a contrast agent while penalizing other signal changes caused by patient motion. A conjugate gradient method is used to find the best possible set of motion parameters that maximizes the similarity measures across the entire volume. Images before and after correction were visually evaluated and scored by experienced radiologists with respect to reduction of motion, improvement of image quality, disappearance of existing lesions or creation of artifactual lesions. It was found that the correction improves image quality (76% for MRM and 96% for MRA) and diagnosability (60% for MRM and 96% for MRA).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1a, b
Fig. 2a, b
Fig. 3a, b
Fig. 4

Similar content being viewed by others

References

  1. Heywang-Köbrunner SH, Viehweg P, Heinig A, Kächler C (1997) Contrast-enhanced MRI of the breast: accuracy, value, controversies, solutions. Eur J Radiol 24:94–108

    Article  PubMed  Google Scholar 

  2. Teifke A, Hlawatsch A, Beier T, Vomweg TW, Schadmand S, Schmidt M, Lehr HA, Thelen M (2002) Undetected malignancies of the breast: dynamic contrast-enhanced MR imaging at 1.0 T. Radiology 224:881–888

    Article  PubMed  Google Scholar 

  3. Fischer H, Otte M, Ehritt-Braun C, Laubenberger J, Hennig J (1999) Local elastic matching and pattern recognition in MR mammography. Int J Imaging Syst Technol 10:199–206

    Article  Google Scholar 

  4. Rueckert D, Sonoda LI, Hayes C, Hill DLG, Leach MO, Hawkes DJ (1999) Non-rigid registration using free-form deformations: application to breast MR images. IEEE Trans Med Imaging 18:712–721

    Article  PubMed  CAS  Google Scholar 

  5. Lucht L, Knopp MV, Brix G (2000) Elastic matching of dynamic MR mammographic images. Magn Reson Med 43:9–16

    Article  PubMed  CAS  Google Scholar 

  6. Tanner C, Schnabel JA, Clarkson MJ, Rueckert D, Hill DLG, Hawkes DJ (2000) Volume and shape preservation of enhancing lesions when applying non-rigid registration to a time series of contrast enhancing MR breast images. In: Delp SL, DiGoia AM, Jaramaz B (eds) Lecture Notes in Computer Science, vol 1935 – Third Int. Conf. on Medical Image Computing and Computer-Assisted Intervention. Springer, Berlin Heidelberg New York, pp 327–337

  7. Schnabel JA, Tanner C, Castellano-Smith AD, Degenhard A, Leach MO, Hose DR, Hill DL, Hawkes DJ (2003) Validation of nonrigid image registration using finite-element methods: application to breast MR images. IEEE Trans Med Imaging 22:238–247

    Article  PubMed  Google Scholar 

  8. Lu W, Chen ML, Olivera GH, Ruchala KJ, Mackie TR (2004) Fast free-form deformable registration via calculus of variations. Phys Med Biol 49:3067–3087

    Article  PubMed  Google Scholar 

  9. He J, Christensen GE (2003) Large deformation inverse consistent elastic image registration. Inf Process Med Imaging 18:438–449

    PubMed  Google Scholar 

  10. Press William H, Teukolsky Saul A, Vetterling William T, Flannery Brian P (1988) Numerical recipes in C. Cambridge University Press, New York

  11. Hermosillo Gerardo (2002) Variational methods for multimodal image matching. PhD thesis, Institut National de Recherche en Informatique et en Automatique (INRIA), Nice

  12. Reichenbach JR, Hopfe J, Bellemann ME, Kaiser WA (2002) Development and validation of an algorithm for registration of serial 3D MR breast data sets. MAGMA 14:249–257

    Article  PubMed  Google Scholar 

  13. Rohlfing T, Maurer CR Jr, Bluemke DA, Jacobs MA (2003) Volume-preserving nonrigid registration of MR breast images using free-form deformation with an incompressibility constraint. IEEE Trans Med Imaging 22:730–741

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to K.-H. Herrmann.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Herrmann, KH., Wurdinger, S., Fischer, D.R. et al. Application and assessment of a robust elastic motion correction algorithm to dynamic MRI. Eur Radiol 17, 259–264 (2007). https://doi.org/10.1007/s00330-006-0224-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-006-0224-3

Keywords

Navigation