Gaceta Sanitaria

Gaceta Sanitaria

Volume 33, Issue 5, September–October 2019, Pages 421-426
Gaceta Sanitaria

Original
Utilidad diagnóstica del cuestionario STOP-Bang en la apnea del sueño moderada en atención primariaDiagnostic accuracy of STOP-Bang questionnaire on moderate sleep apnoea in primary care

https://doi.org/10.1016/j.gaceta.2018.05.003Get rights and content
Under a Creative Commons license
open access

Resumen

Objetivo

Validar el cuestionario STOP-Bang para la apnea moderada frente al método de referencia (polisomnografía de tipo I) en atención primaria.

Método

Estudio de utilidad diagnóstica en atención primaria con una muestra estimada de 85 casos y 85 controles sanos. Con muestreo por conveniencia, 203 pacientes fueron reclutados por sus médicos en seis centros de salud. Se excluyeron 25 y se analizaron 57 mujeres y 121 hombres, de los cuales 74 tenían un índice de hipopnea-apnea (IHA) ≥15. Se evaluaron el STOP-Bang y el IHA observado en la polisomnografía en cada paciente. El tamaño de la muestra, el análisis de la curva ROC y los puntos de corte óptimos se identificaron con los paquetes easyROC, pROC y OptimalCutpoints del software libre R.

Resultados

El área bajo la curva en la apnea moderada (IHA ≥15) del STOP-Bang fue 0,737 (0,667-0,808), con puntos de corte óptimos diferentes por sexo (4 en mujeres y 6 en hombres). En la validación cruzada con k = 10, el área bajo la curva para el STOP-Bang fue 0,678.

Conclusiones

El STOP-Bang tiene una utilidad diagnóstica moderada para un IHA ≥15, pero superior a la de otras escalas, en una población comunitaria. Su desempeño es más adecuado en las mujeres.

Abstract

Objective

We aimed to compare the diagnostic utility of the STOP-Bang questionnaire for moderate apnoea against the gold standard (type I polysomnography) in a primary care setting.

Method

Study of diagnostic utility in primary care. Estimated sample: 85 cases and 85 healthy controls. In convenience sampling, 203 patients were recruited by their physicians at six health centres. Twenty-five were excluded, and 57 women and 121 men, of whom 74 had apnoea-hypopnoea index (AHI) ≥15, were analyzed. STOP-Bang was validated by comparing scores in the same patient with the apnoea-hypopnoea index observed in polysomnography, as a gold standard. Sample size, ROC curve analysis and optimal cut-off points were identified with the easyROC, pROC, and OptimalCutpoints packages.

Results

The area under the curve in moderate apnoea (AHI ≥15) of the STOP-Bang was 0.777 (0.667-0.808), with optimal cut-off points different by sex (4 in women and 6 in men). In the cross-validation with k = 10, the area under the curve for the STOP-Bang was 0.678.

Conclusions

The STOP-Bang presents a diagnostic moderate utility for AHI≥15, but superior to other scales, in a community population. Its performance is more appropriate in women.

Palabras clave

Apnea del sueño
STOP-Bang
Utilidad diagnóstica
Sexo
Atención primaria

Keywords

Sleep apnoea
STOP-Bang
Diagnostic utility
Gender
Primary care