Abstract
Procedures for the determination of gold and silver in copper concentrates, using k 0 based neutron activation analysis, were developed and tested. The effects of gamma-ray self attenuation, neutron self-shielding and spectral interference were considered; precision, accuracy, and detection limits were studied by repeated analysis of copper concentrate internal reference materials. The analytical results have shown good precision and satisfactory accuracy in concordance with the detection limit and range of concentration.
Similar content being viewed by others
References
B. Torres, P. Mendoza, E. Montoya, P. Olivera, P. Bedregal, M. UbillÚs, Determination of precious and rare metals in mineral concentrates and tailings, using k0 instrumental neutron activation analysis, Final Report. Paper presented at the Second Research Coordination Meeting of the IAEA Research Coordinated Programme on ”Validation of Nuclear Techniques for Analysis of Precious and Rare Metals in Mineral Concentrates”, 24-27 May 1999, Bangkok, Thailand.
E. H. Montoya, Evaluación y Estandarización del Análisis por Activación Neutrónica. SegÚn el Método del k-sub-cero en el Reactor Nuclear RP-10-Estudio preliminar empleando irradiaciones cortas, Universidad Peruana Cayetano Heredia, Lima-PerÚ; Master of Sciences Degree Thesis, 1995.
G. Erdtmann, H. Petri, Nuclear Activation Analysis: Fundamentals and Techniques, from Treatise on Analytical Chemistry, Second edition, Part I, Vol. 14, John Wiley &; Sons, Inc., New York, 1986, p. 503.
A. L. Currie, Anal. Chem., 40 (1968) 586.
F. de Corte, Habilitation Thesis, University of Ghent, Faculteit van de Wetenschappen, Belgium, 1987.
A. Koster-Ammerlaan, P. Bode, Sources of Error in INAA of Mineral Concentrates, Interfaculty Reactor Institute, Delft University of Technology, The Netherlands.
E. H. Montoya, I. M. Cohen, P. Mendoza, B. Torres Chamorro, P. Bedregal Salas, J. Radioanal Nucl. Chem., 240 (1999) 475.
K. Heydorn, Aspects of Precision and Accuracy in Neutron Activation Analysis, Risoe-R-419 Risoe National Laboratory, Denmark, Doctor Degree Thesis, 1980.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Torres, B., Montoya, E., Mendoza, P. et al. Determination of gold and silver in copper concentrates, using k0 based neutron activation analysis. Journal of Radioanalytical and Nuclear Chemistry 257, 597–601 (2003). https://doi.org/10.1023/A:1025452901690
Issue Date:
DOI: https://doi.org/10.1023/A:1025452901690