Determination of gold and silver in copper concentrates, using k0 based neutron activation analysis

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Procedures for the determination of gold and silver in copper concentrates, using k 0 based neutron activation analysis, were developed and tested. The effects of gamma-ray self attenuation, neutron self-shielding and spectral interference were considered; precision, accuracy, and detection limits were studied by repeated analysis of copper concentrate internal reference materials. The analytical results have shown good precision and satisfactory accuracy in concordance with the detection limit and range of concentration.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. B. Torres, P. Mendoza, E. Montoya, P. Olivera, P. Bedregal, M. UbillÚs, Determination of precious and rare metals in mineral concentrates and tailings, using k0 instrumental neutron activation analysis, Final Report. Paper presented at the Second Research Coordination Meeting of the IAEA Research Coordinated Programme on ”Validation of Nuclear Techniques for Analysis of Precious and Rare Metals in Mineral Concentrates”, 24-27 May 1999, Bangkok, Thailand.

  2. E. H. Montoya, Evaluación y Estandarización del Análisis por Activación Neutrónica. SegÚn el Método del k-sub-cero en el Reactor Nuclear RP-10-Estudio preliminar empleando irradiaciones cortas, Universidad Peruana Cayetano Heredia, Lima-PerÚ; Master of Sciences Degree Thesis, 1995.

    Google Scholar 

  3. G. Erdtmann, H. Petri, Nuclear Activation Analysis: Fundamentals and Techniques, from Treatise on Analytical Chemistry, Second edition, Part I, Vol. 14, John Wiley &; Sons, Inc., New York, 1986, p. 503.

    Google Scholar 

  4. A. L. Currie, Anal. Chem., 40 (1968) 586.

    Google Scholar 

  5. F. de Corte, Habilitation Thesis, University of Ghent, Faculteit van de Wetenschappen, Belgium, 1987.

  6. A. Koster-Ammerlaan, P. Bode, Sources of Error in INAA of Mineral Concentrates, Interfaculty Reactor Institute, Delft University of Technology, The Netherlands.

  7. E. H. Montoya, I. M. Cohen, P. Mendoza, B. Torres Chamorro, P. Bedregal Salas, J. Radioanal Nucl. Chem., 240 (1999) 475.

    Google Scholar 

  8. K. Heydorn, Aspects of Precision and Accuracy in Neutron Activation Analysis, Risoe-R-419 Risoe National Laboratory, Denmark, Doctor Degree Thesis, 1980.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Torres, B., Montoya, E., Mendoza, P. et al. Determination of gold and silver in copper concentrates, using k0 based neutron activation analysis. Journal of Radioanalytical and Nuclear Chemistry 257, 597–601 (2003). https://doi.org/10.1023/A:1025452901690

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1025452901690