Skip to main content

Integration of Micro Fluidic Bio-chip Design and Automatic fluorescent Identification for Rapid Sperm Mobility Assessment

  • Conference paper
World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany

Part of the book series: IFMBE Proceedings ((IFMBE,volume 25/8))

  • 1011 Accesses

Abstract

Since male abnormality has now been reported to account at least thirty percent of couples with fertility problem. Therefore, distinguishing and classification of sperm has become more and more important, especially when Assisted Reproductive Technology (ART) like in vitro fertilization (IVF) is involved. However, traditional sperm sorting methods all requires manual selection, which is tedious and often cause sperm damage during the screen process. Although, new design from our recent study, seemed to point for a possibility to make these kind of MISS device capable of separating sperms into various mobility sub-class. In addition, the Hoechst 33258 and propidium iodide double staining results, also confirmed that the most motile and health sperm is indeed able to leave the laminar stream and being sorted out at outlet-h, with least dead sperm or debris. Meanwhile, we observed the dead sperm had been dominate from clear red stains and live sperm are not as active as is corresponded with more diffused blue stains. In order to confirm the real sorting situation, we counted the amount of sperm in collected sample by flow cytometry and tried to establish the statistic model. Though the flow cytometry, we could detect the sperm fluorescent distribution and count the size of sperm population. Nevertheless, t-test with 95% confidence level also shown significant difference in live/dead sperm ratio. Therefore, from the combined result among flow cytometry, fluorescent stain, and the statistic model test, it is confirmed that live sperms were able to cross the laminar stream created by the device and reach the sorting chamber with corresponding range from non-motile sperms to debris, as well as from living to dead ones. It is concluded that the proposed method is cost effective and is possible to serve as a protocol for rapid sperm quantitative assessment.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 International Federation for Medical and Biological Engineering

About this paper

Cite this paper

Pan, LC. et al. (2009). Integration of Micro Fluidic Bio-chip Design and Automatic fluorescent Identification for Rapid Sperm Mobility Assessment. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/8. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03887-7_96

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03887-7_96

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03886-0

  • Online ISBN: 978-3-642-03887-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics