An infrared hygrometer witH on-line temperature compensation

  • Research Note
  • Published:
Boundary-Layer Meteorology Aims and scope Submit manuscript

Abstract

A single-beam infrared absorption hygrometer for measuring fluctuations in atmospheric water vapour and suitable for use in eddy correlation studies of evatranspiration is described. This instrument differs from previously described devices since it incorporates a method for monitoring detector responsivity and correcting for temperature-induced changes in this responsivity. Without such a correction, changes in the hygrometer calibration coefficient, due to instrument temperature effects, can be as large as 30% during energy balance studies over grassland.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Coppin, R. A. and Taylor, K. J.: 1983, ‘A Three-Component Sonic Anemometer/Thermometer System for General Micrometeorological Research’, Boundary-Layer Meteorol. 27, 27–42.

    Google Scholar 

  • Goody, R. M.: 1952, ‘A Statistical Model for Water-Vapour Absorption’, Quart. J. R. Meteorol. Soc. 78, 165–169.

    Google Scholar 

  • Humphrey, J. N.: 1965, ‘Optimum Utilization of Lead Sulphide Infrared Detectors Under Diverse operating Conditions’, Applied Optics 4, 665–675.

    Google Scholar 

  • Hyson, P. and Hicks, B. B.: 1975, ‘A Single-Beam Infrared Hygrometer for Evaporation Measurement’, J. Appl. Meteorol. 14, 301–307.

    Google Scholar 

  • Jamieson, J. A., McFee, R. H., Plass, G. N., Grube, R. H., and Richards, R. G.: 1964, ‘Infrared Physics and Engineering’, McGraw-Hill, N.Y. (Chapter 3).

    Google Scholar 

  • McBean, G. A.: 1972, ‘Instrument Requirements for Eddy Correlation Measurements’, J. Appl. Meteorol. 11, 1078–1084.

    Google Scholar 

  • Moore, C. J.: 1983, ‘On the Calibration and Temperature Behaviour of Single-Beam Infrared Hygrometers’, Boundary-Layer Meteorol. 25, 245–269.

    Google Scholar 

  • Pond, S., Phelps, G. T., Paquin, J. E., McBean, G., and Stewart, R. W.: 1971, ‘Measurements of the Turbulent Fluxes of Momentum, Moisture and Sensible Heat over the Ocean’, J. Atmos. Sci. 28, 901–917.

    Google Scholar 

  • Raupach, M. R.: 1978, ‘Infrared Fluctuation Hygrometer in the Atmospheric Surface Layer’, Quart. J.R. Meteorol. Soc. 104, 309–322.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Trevitt, A.C.F. An infrared hygrometer witH on-line temperature compensation. Boundary-Layer Meteorol 34, 157–169 (1986). https://doi.org/10.1007/BF00120914