Increasing glucose determination range by flow injection analysis (FIA) using glucose oxidase immobilised on polyaniline

  • Published:
Biotechnology Techniques

Abstract

A Flow Injection Analysis (FIA) for glucose using glucose oxidase (E.C.1.1.3.4) was developed. The enzyme was immobilised on polyaniline chemically synthetized on internal surface of silicon tube (2.0 mm of diameter and length from 1 to 5 meters), using glutaraldehyde as a bifunctional agent. The system was able to measure glucose at levels from 5 to 500mM with a response time of 2min using 250μl of sample. The system has been operated satisfactorily for one month with more than 300 assays with loss of 60% of activity.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bernfeld,P. (1955), Methods in Enzymology, Vol.1, Acad. Press, New York, pp.149–150.

    Google Scholar 

  • Clarke,L.C. and Lyons,C. (1962), Ann.NY Acad. Sci. 102,29.

    Google Scholar 

  • Updike, S.J. and Hicks, G.P. (1967), Nature, 214,986–988.

    Google Scholar 

  • Hirose, S. Hayashi, M., Tamura, N., Suzuki, S. and Karube, I. (1979), J.Mol. Catal., 6,251–260.

    Google Scholar 

  • Kezukharova, A., Kirova, N., Popova, Y., Batsalova, K. and Kunchev, K. (1988), Biotechnol. and Bioeng. 32,245–248.

    Google Scholar 

  • Parente,A.H., Marques Jr, E.T.A., Azevedo,W.M.,Diniz,F.B., Melo,E.H.M. and Lima Filho,J.L. (1993), Appl. Biochem. Biotechnol. 37,267–273.

    Google Scholar 

  • Haemmerli,S., Schaeffler,A., Manz,A. and Widmer,H.M. (1992), Sensors and Actuators, 7,404–407.

    Google Scholar 

  • Marques Jr, E.T.A., Spencer Neto,F.A.C., Lima Filho, J.L. (1991), Biochem. Educa., 19,77–78.

    Google Scholar 

  • Yabuki,S., Mizutani,F. & Katsura,T. (1992), Biosensors & Bioeletronics, 7,695–700.

    Google Scholar 

  • Urban,G., Jobst,G., Keplinger,F., Aschauer,E., Tilado,O., Fasching,R. & Kohl,F. (1992). Biosensors & Bioeletronics. 7,733–739.

    Google Scholar 

  • Mascini,M. and Selleri,S. (1989) Anal. Lett., 22(6), 1429–1449.

    Google Scholar 

  • Lowry, O. H., Rose Brough, N. J., Farr, A.L., and Randall, R.J. (1955), J. Biol. Chem. 193,265–275.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Leite, V., da Silva, V.L., Azevedo, W.M. et al. Increasing glucose determination range by flow injection analysis (FIA) using glucose oxidase immobilised on polyaniline. Biotechnol Tech 8, 133–136 (1994). https://doi.org/10.1007/BF00152854

Download citation

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00152854

Keywords

Navigation