Abstract
A simple, non-invasive, non-radioactive liverfunction test is proposed. After an oral dose of 3 mg 15N-methacetin per kilogram body mass, the kinetics of 15N excretion via urine were characterized by the quotient of the amounts of 15N excreted in two successive urine samples (Q value). The stable nitrogen isotope 15N was found to be an excellent and easily detectable indicator of the sum of all methacetin metabolites present in urine. Alterations in the nature or ratio of methacetin metabolites due to liver diseases could not be found. From the investigation of 11 men, 3 pregnant women and 15 children, a clear difference was observed in Q values of healthy persons and patients suffering from liver-cell-activity diseases. The discriminating power of our new liver-function test is shown to be equivalent to that of the 14CO2 breath test.
Similar content being viewed by others
References
Andreasen PB (1976) Drug metabolism and quantitative liver function. Arzneimittelforsch 26:1263–1266
Andreasen PB, Ranek L, Statland BEF, Tygstrup N (1974) Clearance of antipyrine: dependence of quantitative liver function. Eur J Clin Invest 4:129–134
Brown SS, Mitchell FL, Young DS (1979) Chemical diagnosis of disease. Elsevier/North Holland Biomedical Amsterdam
Caspary WF (1978) Atemanalytische Tests in der Leberfunktionsprüfung. Z Gastroenterol 16:188–197
Faust H, Bornhak H, Hirschberg K, Jung K, Junghans P, Krumbiegel P, Reinhardt R (1981a) Klinisch-chemische und isotopenanalytische Methoden zur Untersuchung des Stickstoffstoffwechsels mit 15N beim Menschen. ‘Methodenkatalog’, Zfl-Mitteilungen, No 36. Akademie der Wissenschaften der DDR, Zentralinstitut für Isotopen- und Strahlenforschung Leipzig
Faust H, Jung K, Krumbiegel P (1981b) Stabile Isotope in der medizinischen Forschung. Isotopenpraxis 17:193–200
Jung K, Hirschberg K, Faust H, Matkowitz R (1985) A liver function test with 15N-labelled ammonium chloride. Eur J Nucl Med (in press)
Krumbiegel P, Günther K, Faust H, Möbius G, Hirschberg K, Schneider G (1985) Nuclear medicine liver function tests for pregnants women and children. 1. Breath tests with 14C-methacetin and 13C-methacetin. Eur J Nucl Med 10:129–133
Lauterburg BH, Bircher J (1973) Hepatic microsomal drug metabolizing capacity measured in vivo by breath analysis. Gastroenterology 65:556
Meier G, Mauersberger K (1982) NOI-6 — ein neuer emissionsspek-trometrischer Analysator. Isotopenpraxis 18:164–170
Schoeller DA, Schneider JF, Solomons NW, Watkins JB, Klein PD (1977) Clinical diagnosis with the stable isotope 13C in CO2 breath tests: methodology and fundamental considerations. J Lab Clin Med 90:412–421
Smith GE, Griffiths LA (1976) Comparative metabolic studies of phenacetin and structurally related compounds in the rat. Xenobiotica 6:217–236
TGL 14466 (1969) ‘Stabilisotop markierte chemische Elemente und Verbindungen’ pt 3. Anwendung in der Humanmedizin und Lebensmittelindustrie. DDR-Standard ab 1.1.1970. Amt für Standardisierung (Publ.). Fachbuchverlag Leipzig
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Krumbiegel, P., Hirschberg, K., Faust, H. et al. Nuclear medicine liver-function tests for pregnant women and children. Eur J Nucl Med 11, 58–61 (1985). https://doi.org/10.1007/BF00252133
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00252133