Skip to main content
Log in

A flexible system for microscope fluorometry served by a personal computer

  • Published:
Histochemistry Aims and scope Submit manuscript

Summary

An automated microscope fluorometer based on a modified Leitz MPV I system is described. Automation is mainly attained by the use of a cheap, commercially available personal computer system programmed in extended BASIC supplemented by a few assembly-level subroutines. The automation has resulted in simplified measuring procedures and increased measuring speed. The statistical precision is enhanced because greater cell populations can be analysed within reasonable time. Programs for several biological applications are described. Routines for cell population analysis, including storage of data on disk files, has proved especially useful. Programs for recording of corrected fluorescence emission spectra and of time-dependent fluorescence variables have also been developed. A high flexibility is achieved, as the BASIC programs can readily be modified for specific purposes. Some data on the sensitivity and reproducibility of the instrument alone, and in combination with a staining method, are also presented.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Caspersson T, Lomakka G, Rigler R (1965) Registrierender Fluoreszenzmikrospektrograph zur Bestimmung der Primär- und Sekundärfluoreszenz verschiedener Zellsubstanzen. Acta Histochem 6 (Suppl):123–126

    Google Scholar 

  • Cova S, Prenna G, Mazzini G (1974) Digital microspectrofluorometry by multichannel scaling and single photon detection. Histochem J 6:279–299

    Google Scholar 

  • Doerr J (1978) Low-cost microcomputing: The personal computer and single-board computer revolutions. Proc IEEE 66:117–130

    Google Scholar 

  • Enerbäck L, Johansson K-A (1973) Fluorescence fading in quantitative fluorescence microscopy: a cytofluorometer for the automatic recording of fluorescence peaks of very short duration Histochem J 5:351–362

    Google Scholar 

  • Enerbäck L, Rundquist I (1980) DNA distributions of mast cell populations in growing rats. In preparation

  • Enerbäck L, Gustafsson B, Mellblom L (1977) Cytofluorometric quantitation of 5-hydroxytryptamine in mast cells: an improved technique for the formaldehyde condensation reaction. J Histochem Cytochem 25:32–41

    Google Scholar 

  • Haaijman JJ, Wijnants FAC (1975) Inexpensive automation of the Leitz orthoplan microfluorometer using pneumatic components. J Immunol Methods 7:255–270

    Google Scholar 

  • Horan PK, Wheeless LL (1977) Quantitative single cell analysis and sorting. Science 198:149–157

    Google Scholar 

  • Jongsma APM, Hijmans W, Ploem JS (1971) Quantitative immunofluorescence, standardization and calibration in microfluorometry. Histochemie 25:329–343

    Google Scholar 

  • Jotz MM, Gill JE, Davis DT (1976) A new optical multichannel microspectrofluorometer. J Histochem Cytochem 24:91–99

    Google Scholar 

  • Ploem JS (1970) Standards for fluoroescence microscopy. In: Holborow EJ (ed) Standardization in immunofluorescence. Blackwell, Oxford Edinburg, pp 137–153

    Google Scholar 

  • Ploem JS, de Sterke JA, Bonnet J, Wasmund H (1974) A microspectrofluorometer with epi-illumination operated under computer control. H Histochem Cytochem 22:668–677

    Google Scholar 

  • Rasch EM, Rasch RW (1979) Applications of microcomputer technology to cytophotometry. J Histochem Cytochem 27:1384–1387

    Google Scholar 

  • Ritzén M (1967) Cytochemical identification and quantitation of biogenic monoamines. A microspectrofluorometric and autoradiographic study. MD thesis, Stockholm

  • Rost FWD, Pearse AGE (1971) An improved microspectrofluorimeter with automatic digital data logging: construction and operation. J Microsc 94:93–105

    Google Scholar 

  • Ruch F (1973) The use of human leucocytes as a standard for the cytofluorometric determination of protein and DNA. In: Thaer AA, Sernetz M (eds) Fluorescence techniques in cell biology. Springer, Berlin Heidelberg New York, pp 51–55

    Google Scholar 

  • Ruch F, Leeman U (1973) Cytofluorometry. In: Neuhoff V (ed) Micromethods in molecular biology. Springer, Berlin Heidelberg New York, pp 329–346

    Google Scholar 

  • Rundquist I, Enerbäck L (1976) Millisecond fading and recovery phenomena in fluorescent biological objects. Histochemistry 47:79–87

    Google Scholar 

  • Sernetz M, Thaer A (1970) A capillary fluorescence standard for microfluorometry. J Microsc 91:43–52

    Google Scholar 

  • Shapiro MB, Schultz AR, Jennings WH (1976) Computers in the research laboratory. Annu Rev Biophys Bioeng 5:177–204

    Google Scholar 

  • Shipton HW (1979) The microprocessor, a new tool for the biosciences. Annu Rev Biophys Bioeng 8:269–286

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Supported by grants from the Swedish Medical Research Council (Project No. 2235) and from the Faculty of Medicine, University of Linköping

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rundquist, I. A flexible system for microscope fluorometry served by a personal computer. Histochemistry 70, 151–159 (1981). https://doi.org/10.1007/BF00493207

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00493207

Keywords

Navigation