High compression of nuclear medicine dynamic studies

  • Published:
The International Journal of Cardiac Imaging Aims and scope Submit manuscript

Summary

As data compression plays now an important role in the development of medical PACS, a technique has been developed for medical image sequences storage and transmission in order to obtain very high compression ratio: in dynamic nuclear medicine studies it can achieve a compression ratio as high as 100:1 without significant degradation. The implemented technique combines two methods which multiply their effects. In a first step, a principal component analysis (PCA) of the image series is performed. It extracts a limited number of principal components and their associated images. For data compression it is not necessary to perform an oblique factor analysis to estimate the so-called ‘physiological functions’ and their spatial distributions as in factor analysis of dynamic structures (FADS). In a second step, the principal images are compressed by means of a transform coding procedure: an adaptive block-quantization technique using the 2D discrete cosine transform (DCT) is implemented, followed by a statistical quantization method to encode the DCT coefficients. To reconstruct the principal images, an inverse DCT is applied. Then the original series is computed from the reconstructed images combined with the principal components which have been stored without any modification. The reconstructed series is compared to the original series, as well as the time activity curves generated on different regions of interest (ROI) and the factor estimates obtained using FADS performed on the two series. Method and evaluation are illustrated on an example of first pass radionuclide angiocardiography.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Templeton AW, Dwyer SJ, Cox GG, Lee KR, Johnson JA, Martin NL, Chang CH, Anderson WH, Bailek J. A digital radiology imaging system: a description and clinical evaluation. AJR 1987; 149: 847–851.

    Google Scholar 

  2. Jain AK. Image data compression: A review. Proc. IEEE 1981; 69: 349–389.

    Google Scholar 

  3. Netravali AN, Limb JO. Picture coding: A review. Proc. IEEE 1980; 68: 366–406.

    Google Scholar 

  4. Appledorn CR, Todd-Pokropek AE. Error-free compression applicable to PACS. In: de Graaf CN, Viergever MA, eds. Information Processing in Medical Imaging. New York: Plenum 1987; 325–333.

    Google Scholar 

  5. Quinn JF, Rhodes ML, Rosner B. Data compression techniques for CT image archival. In: Dwyer SJ, ed. Picture Archiving and Communication Systems (PACS II) for Medical Applications. Washington: SPIE 1983; 418: 209–212.

    Google Scholar 

  6. Kunt M. Source coding of X-ray pictures. IEEE Trans. Biomed. Eng. 1978; 25: 121–138.

    Google Scholar 

  7. Okada M. Storage volume of computer tomography images can be reduced by a factor five. Comput. Meth. Progr. Biomed. 1985; 20: 151–157.

    Google Scholar 

  8. Huang HK, Lo SC, Ho BK, Lou SL. Radiological image compression using error-free and irreversible two-domensional direct-cosine-transform coding techniques. J. Opt. Soc. Am. 1987; 4: 984–992.

    Google Scholar 

  9. Höhne KH, Obermöller U, Riemer M, Witte G. Fourier domain techniques for digital angiography of heart. IEEE Trans. Med. Imaging 1984; MI-3: 62–67.

    Google Scholar 

  10. Peters JH, Roos P, Van Dijke MCA, Viergever MA. Lossless compression in digital angiography. In: de Graaf CN, Viergever MA, eds. Information Processing in Medical Imaging. New York: Plenum 1987; 335–341.

    Google Scholar 

  11. Cavailloles F, Bazin JP, Capderou A, Valette H, Herbert JL, Di Paola R. Automated processing of first-pass radionuclide angiocardiography by factor analysis of dynamic structures. Nucl. Med. Comm. 1987; 8: 385–387.

    Google Scholar 

  12. Di Paola R, Penel C, Bazin JP, Berche C. Factor analysis and scintigraphy. In: Raynaud C, Todd-Pokropek AE, eds. Information Processing in Scintigraphy. Orsay: CEA 1976; 1: 91–123.

    Google Scholar 

  13. Di Paola R, Bazin JP, Aubry F, Aurengo A, Cavailloles F, Herry JY, Kahn E. Handling of dynamic sequences in nuclear medicine. IEEE Trans. Nucl. Sci. 1982; NS-29: 1310–1321.

    Google Scholar 

  14. Barber DC. The use of principal components in the quantitative analysis of gamma camera dynamic studies. Phys. Med. Biol. 1980; 25: 283–292.

    Google Scholar 

  15. Pratt WK. Digital image processing. New York: John Wiley, 1978.

    Google Scholar 

  16. Rosenfeld A, Kak AC. Digital picture processing. New York: Academic Press, 1982.

    Google Scholar 

  17. Ahmed N, Natarajan T, Rao KR. Discrete cosine transform. IEEE Trans. Comput. 1974; C-23: 90–93.

    Google Scholar 

  18. Ahmed N, Rao KR. Orthogonal transforms for digital signal processing. Berlin: Springer, 1975.

    Google Scholar 

  19. Bacchi H. Considérations sur le choix des transformations orthogonales et sur leurs perspectives. Acta Electronica 1976; 19: 299–332.

    Google Scholar 

  20. Di Paola R, Todd-Pokropek AE. New developments in techniques for information processing in radionuclide imaging. In: Medical Radionuclide Imaging. Vienna: IAEA 1980; 287–312.

    Google Scholar 

  21. Aurengo A, Bazin JP, Lumbroso J, Di Paola R. Factor analysis as an aid in the interpretation of dynamic scintigrams of transplanted kidneys. In: Raynaud C, ed. Nuclear Medicine and Biology. Paris: Pergamon Press 1982; 4: 3167–3170.

    Google Scholar 

  22. Edeline V, Bazin JP, Di Paola M, Lumbroso J, Kalifa C, Contesso G, Di Paola R, Parmentier C. Qu'est ce qu'un bon ou mauvaus répondeur au traitement des ostéosarcomes par chimiothérapie? Une application de l'analyse factorielle en scintigraphie osseues. J. de Médecine Nucléaire et Biophysique 1988; 12: 372.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Chameroy, V., Di Paola, R. High compression of nuclear medicine dynamic studies. Int J Cardiac Imag 5, 261–269 (1990). https://doi.org/10.1007/BF01797843

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01797843

Key words

Navigation