Skip to main content
Log in

A second generation twin double microcalorimeter

Measurements of sorption isotherms, heats of sorption and sorption kinetics

  • Instrumentation
  • Published:
Journal of thermal analysis Aims and scope Submit manuscript

Abstract

A calorimetric method for the study of solid-vapor interactions is described. In one calorimetric chamber a vapor evaporates; in a second calorimetric chamber the vapor is absorbed by a sample. The two chambers are connected by a tube and form part of a double twin microcalorimeter. As vapor is sorbed by the sample the vapor pressure in the sorption chamber will increase from a low value to near saturation. The flow rate of the vapor is governed by diffusion through the tube between the vessels. From the thermal power measured in the vaporization calorimeter it is possible to evaluate the sorption isotherm, and using information from both calorimeters the heat of sorption may be calculated as a function of equilibrium vapor pressure. By conducting experiments with different sized samples it is also possible to study the kinetics of the sorption process. The paper describes some recent improvements of the technique and gives examples of its use.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. I. Wadsö and L. Wadsö, Thermochim. Acta, 273 (1996) 277.

    Article  Google Scholar 

  2. E. Calvet, C. R. Acad. Sci. Paris, 236 (1953) 377, 486.

    CAS  Google Scholar 

  3. R. W. Wood, L. D. Hansen and J. W. Crawford, United States Patent 5266492, Nov. 30, 1993.

    Google Scholar 

  4. L. Wadsö, J. Mater. Sci., 29 (1994) 2367.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This work has been supported by the Swedish Natural Science Research Council (to IW), the Swedish Building Research Council (to LW) and the Lisshed Foundation, Stockholm (to LW).

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wadsö, I., Wadsö, L. A second generation twin double microcalorimeter. Journal of Thermal Analysis 49, 1045–1052 (1997). https://doi.org/10.1007/BF01996792

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01996792

Keywords

Navigation