Abstract
A rapid method for determining traces of radiostrontium in milk and drinking water is described. The technique involves a batch treatment of the milk sample with a cation exchanger (DOWEX 50W X8) followed by a solvent extraction with a crown ether (DC18C6) and a precipitation of SrCO3. In the case of water, the strontium is extracted directly with the crown ether. The average separation yield is 74% for milk and 91% for water. The overall separation procedure takes about 8 hours. Activities as low as 0.03 Bq/1 can be determined with a low background GM-counter.
Similar content being viewed by others
References
M. SENEGACNIK, S. PALJK, J. KRISTAN, Z. Anal. Chem., 249 (1970) 39.
N. BORUS-BÖSZÖRMÉNYI, J. KOVACS, J. Radioanal. Chem., 68 (1982) 23.
C. FRIEDLI, J. J. GEERING, P. LERCH, R. C. IVe Symp. Internat. Radioécologie, Cadarache, March 14–19, 1988. F114.
P. WALSTRA, R. JENNESS, Dairy Chemistry and Physics, John Wiley & Sons, New York, 1984.
L. F. EDMONDSON, J. Dairy Sci., 47 (1964) 1201.
J. P. WALKER, F. L. EDMONDSON, Health Phys., 16 (1969) 85.
E. BLASIUS, W. KLEIN, U. SCHOEN, J. Radioanal. Nucl. Chem., 89 (1985) 389.
E. J. LANGROCK, Patent Ger. (DDR) DD 217190 Al, 1985.
G. L. SMITH, S. B. REES, D. R. WILLIAMS, Polyhedron, 4 (1985) 713.
T. KIMURA, K. IWASHIMA, T. ISHIMORI, T. HAMADA, Anal. Chem., 51 (1979) 1113.
P. LERCH, P. BERCIER, Chimia, 18 (1964) 16.
L. A. CURRIE, Anal. Chem., 40 (1968) 586.