Dynamic thermographic imaging method for quantifying dermal perfusion: potential and limitations

  • Physiological Measurement
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A new method of quantifying dermal perfusion on a regional basis using a dynamic thermographic technique is investigated. The technique is based on the relationship between dermal perfusion and the rate of skin surface reheating following the application of a transient cold challenge predicted by a theoretical model. Measurements were made using images from a Philips thermographic camera under rigorously controlled conditions. Experimentation on undisturbed volar forerm skin of normal subjects showed that measurements could be repeated with good accuracy but that differences in normalised reheat temperatures between subjects were highly dependent on subcutaneous fat thickness. Comparisons between normal and occluded foreams indicated that reheat temperatures were not sensitive to changes in low levels of dermal perfusion. Conversely, stimulation of dermal blood flow with prostaglandin E2 did produce significant differences from control conditions, but quantifying the axtent of this hyperaemia was limited by the effects of intersubject variations in fat thickness. Quantifying skin blood flow from skin temperature reheat rates is shown to be limited by a lack of sensitivity and a dependence on subcutaneous fat thickness, although dynamic thermography is able to provide useful information on regional variations in skin perfusion which could not be reliably obtained from static temperature measurements alone.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Allen, P. I. M. andGoldman, M. (1987). Skin blood flow: a comparison of transcutaneous oximetry and laser Doppler flowmetry.Eur. J. Plastic Surg.,1, 315–318.

    Google Scholar 

  • Bergqvist, D. andBornmyr, S. (1986) New aspects of thermography as a non-invasive diagnostic method for arteriovenous anastomoses in the extremities.VASA,15, 241–244.

    Google Scholar 

  • Corcoran, J. S., Owens, C. W. I. andYudkin, J. S. (1987). Measurement of fingertip blood flow using thermal clearance reflects anastomotic rather than nutrient blood flow.Clin. Sci.,72, 225–232.

    Google Scholar 

  • Fairs, S. L. E., de Trafford, J. C. andRoberts, V. C. (1985) Optical methods for measuring blood flow in skin. InPractical aspect of skin blood flow measurement. BES Conference Proceedings Volume 1.Spence, V. A. andSheldon, C. D. (Eds.), Biological Engineering Society, London.

    Google Scholar 

  • Francis, J. E., Roggli, R., Love, T. J. andRobinson, C. P. (1979) Thermography as a means of blood perfusion measurement.Trans. ASME,101, 246–249.

    Google Scholar 

  • Harper, E. I., Swanson-Beck, J., Spence, V. A. andBrown, R. A. (1988) Effects of histamine and prostaglandin E2 on the microcirculation in the skin.Agents & Actions,24, 102–108.

    Article  Google Scholar 

  • Holloway, G. A. (1983) Laser Doppler measurement of cutaneous blood flow. InNon-invasive physiological measurement.Rolfe, P. (Ed.), Academic Press, London, UK, 214–250.

    Google Scholar 

  • Keatinge, W. R. andHarman, M. C. (1980) Direct effect of temperature on blood vessels. InLocal mechanisms controlling blood vessels. Physiological Society Monograph 37, Academic Press, London, UK.

    Google Scholar 

  • Khan, F., Spence, V. A., Walker, W. F. andWilson, S. B. (1988) Regional differences in cutaneous vasoconstriction in the arm following indirect body heating in humans.J. Physiol.,399, 81P.

    Google Scholar 

  • Love, T. J. (1980) Thermography as an indicator of blood perfusion.Ann. N.Y. Acad. Sci.,335, 429–437.

    Google Scholar 

  • Sejrsen, P. (1972) Measurement of cutaneous blood flow by freely diffusible radioactive isotopes.Danish Med. Bull.,18, Suppl. 3, 1–38.

    Google Scholar 

  • Theuvenet, W. J., Koeyers, G. F. andBorghouts, M. H. M. (1986) Thermographic assessment of perforating arteries.Scand. J. Plast. Reconstr. Surg.,20, 25–29.

    Google Scholar 

  • Tooke, J. E. andRayman, G. (1985). The investigation of the foot skin microcirculation in diabetes mellitus. InPractical aspect of skin blood flow measurement. BES Conference Proceedings Volume 1,Spence,V. A. andSheldon,C. D. (Eds.), Biological Engineering Society, London.

    Google Scholar 

  • Wilson, S. B. andSpence, V. A. (1988) A tissue heat transfer model for relating dynamic skin temperature changes to physiological parameters.Phys. in Med. & Biol.,33, 895–912.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wilson, S.B., Spence, V.A. Dynamic thermographic imaging method for quantifying dermal perfusion: potential and limitations. Med. Biol. Eng. Comput. 27, 496–501 (1989). https://doi.org/10.1007/BF02441468

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02441468

Keywords

Navigation