Two-frequency impedance plethysmograph: real and imaginary parts

  • Instrumentation
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A four-channel impedance plethysmograph has been designed. Impedance signals are obtained at two frequencies by measuring both real and imaginary parts. Particular attention has been paid to the sine wave generation circuits that provide system versatility. The required phase-sensitive demodulation is achieved by means of analogue multiplexers. Results show that there are significant variations in the thoracic equivalent capacitance related to respiration and that there is an increased sensitivity to cardiac activity at low frequencies.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Arenson, J. S., Cobbold, R. S. C. andJohnston, K. W. (1981) Dual-channel self-balancing impedance plethysmograph for vascular studies.Med. & Biol. Eng. & Comput.,19, 157–164.

    Article  Google Scholar 

  • Evans, W. A. andTowers, M. S. (1980) Hybrid technique in waveform generation and synthesis.IEE Proc., Part G,127, 119–128.

    Google Scholar 

  • Griffiths, H. andAhmed, A. (1987) A dual-frequency applied potential tomography technique computer simulations.Clin. Phys. Physiol. Meas,8, Suppl. A, 103–107.

    Article  Google Scholar 

  • Pething, R. (1987) Dielectric properties of body tissues. —Ibid.,8, 5–12.

    Article  Google Scholar 

  • Rosell, J., Murphy, D., Pallas, R. andRolfe, P. (1988) Analysis and assessment of errors in a parallel data acquisition system for biomedical impedance tomography, —Ibid.,9, Suppl. A, 93–99.

    Article  Google Scholar 

  • Shankar, T. M. R. andWebster, J. G. (1984) Automatically balancing electrical impedance plethysmography.J. Clin. Eng. 9, 129–134.

    Google Scholar 

  • Swanson, D. K. andWebster, J. G. (1982) Simple design for an impedance plethysmograph.Med. & Biol. Eng. & Comput.,20, 461–465.

    Article  Google Scholar 

  • Swanson, D. K. andWebster, J. G. (1983) Errors in four-electrode impedance plethysmography. —Ibid.,21, 674–680.

    Google Scholar 

  • thomasset, A., Lenoir, J., Jenin, P. andGharib, C. (1987) Estimation of body fluid shift by electrical impedance in various postures. Proc. 3rd European Symp. on Life Sci. Res. in Space, Graz, Austria, Sept. 1987, 323–325.

  • Towers, M. S. (1982) Programmable waveform generator using linear interpolation with multiplying D/A convertors.IEE Proc., Part G,129, 19–25.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lozano, A., Rosell, J. & Pallás-Areny, R. Two-frequency impedance plethysmograph: real and imaginary parts. Med. Biol. Eng. Comput. 28, 38–42 (1990). https://doi.org/10.1007/BF02441675

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02441675

Keywords

Navigation