Skip to main content
Log in

Long-term implants of Parylene-C coated microelectrodes

  • Communication
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  • Bak, M. J. andSchmidt, E. M. (1977a) An improved time-amplitude window discriminator.IEEE Trans. BME-24, 485–489.

    Google Scholar 

  • Bak, M. J. andSchmidt, E. M. (1977b) An analog delay circuit for on-line visual confirmation of discriminated neuroelectric signals,--24, 69–71.

    Google Scholar 

  • Delgado, J. M. R. (1961) Chronic implantation of intracerebral electrodes in animals. InElectrical stimulation of the brain.Sheer, D. E. (Ed.), University of Texas Press, Austin.

    Google Scholar 

  • Loeb, G. E., Bak, M. J., Salcman, M. andSchmidt, E. M. (1977a) Parylene as a chronically stable, reproducible micro-electrode insulator.IEEE Trans,BME-24, 121–128.

    Google Scholar 

  • Loeb, G. E., Walker, A. E., Uematsu, S. andKonigsmark, B. W. (1977b) Histological reaction to various conductive and dielectric films chronically implanted in the subdural space.J. Biomed. Mat. Res.,11, 195–210.

    Article  Google Scholar 

  • Marg, E. (1964) A rugged, reliable and sterilizable microelectrode for recording single units from the brain.Nature,202, 601–603.

    Article  Google Scholar 

  • Salcman, M. andBak, M. J. (1976) A new chronic recording intracortical microelectrode.Med. Biol. Eng.,14, 42–50.

    Google Scholar 

  • Schmidt, E. M., Bak, M. J. andMcIntosh, J. S. (1976) Long-term chronic recording from cortical neurons.Exp. Neurol.,52, 496–506.

    Article  Google Scholar 

  • Schmidt, E. M. (1983) Parylene as an electrode insulator: a review.J. Electrophysiol. Tech.,10, 19–29.

    Google Scholar 

  • Wolbarsht, M. L., McNichol, E. F. Jr andWagner, H. G. (1960) Glass insulated platinum microelectrodes.Seience,132, 1309–1310.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schmidt, E.M., Mcintosh, J.S. & Bak, M.J. Long-term implants of Parylene-C coated microelectrodes. Med. Biol. Eng. Comput. 26, 96–101 (1988). https://doi.org/10.1007/BF02441836

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02441836

Keywords

Navigation