Abstract
A combined correlation analysis of temporal and spatial patterns in a biomagnetic multichannel recording is proposed to extract patterns of transient, randomly repetitive physiological events from biomagnetic data sets with a low signal-to-noise ratio. This method is especially sensitive in the differentiation of signals from different source propagation pathways. The recognition and subsequent averaging of spike events in the MEG of an epileptic patient by this method is shown to provide an essential improvement in the signal-to-noise ratio. The source localisation from the averaged data showed electrical activity which propagated from the primary epileptogenic focus to distant parts of the brain.
Similar content being viewed by others
References
Abraham-Fuchs, K., Schneider, S. andReichenberger, H. (1988) MCG inverse solution: influence of coil size, grid size, number of coils, and SNR.IEEE Trans.,BME-35, 573–576.
Abraham-Fuchs, K., Weikl, A., Schneider, S., Moshage, W., Röhrlein, G., Wirth, A., Bachmann, K. andSchittenhelm, R. (1989) Application of a biomagnetic multichannel system to the comparative localization of accessory conduction pathways in patients with WPW syndrome. 7th Int. Conf. on Biomagnetism, New York University, 14th–18th Aug., 263–264.
Barth, D. S., Sutherling, W., Engel, J. Jr, andBeatty, J. (1984a) Neuromagnetic localization of single and multiple sources underlying epileptiform spikes in the human brain. InAdvances in epileptology: XV Epilepsy Int. Symp, Raven Press, New York, 379–384.
Barth, D. S., Sutherling, W., Engel, J. Jr andBeatty, J. (1984b) Neuromagnetic evidence of spatially distributed sources underlying epileptiform spikes in the human brain.Science,223, 293–296.
Barth, D. S., Sutherling, W., Broffman, J. andBeatty, J. (1986) Magnetic localization of dipolar current source implanted in a sphere and a human cranium.Electroenceph. Clin. Neurophysiol.,63, 260–273.
Chapman, R. M., Romani, G. L., Barbanera, S. andLeoni, R. (1983) SQUID instrumentation and the relative covariance method for magnetic 3D localization of pathological cerebral sources.Lettere al Nuovo Cimento,38, 549–554.
Cohen, A. (1986)Biomedical signal processing, Vol. I, CRC Press, Boca Raton, Florida.
Cuffin, B. N. (1986) Effects of measurement errors and noise on MEG moving dipole inverse solutions.IEEE Trans.,BME-33, 854–860.
Cuffin, B. N. (1987) The role of model and computational experiments in the biomagnetic inverse problem.Phys. in Med. & Biol.,32, 33–42.
Curio, G., Erné, S. N., Scheer, J., Stehr, R. andTrahms, L. (1989) Short latency somatosensory evoked magnetic fields recorded over the brachial plexus and cervical spine in man. 7th Int. Conf. on Biomagnetism, New York University, 14th–18th Aug., 339.
de Munck, J. C., van Dijk, B. W. andSpekreijse, H. (1988) Mathematical dipoles are adequate to describe realistic generators of human brain activity.IEEE Trans.,BME-35, 960–966.
Erné, S. N. (1985) High resolution magnetocardiography: modeling and sources localization. Proc. 14th ICMBE and 7th ICMP, Espoo. Finland, Aug. 1985,Med. & Biol. Eng. & Comput.,23, Suppl., Part 2, 1447–1450.
Erné, S. N., Trahms, L. andTrontelj, Z. (1987) Clustering—a novel approach for selected averaging of biomagnetic signals. 6th Int. Conf. on Biomagnetism, Tokyo, 27th–30th Aug. 1987, 298–301.
Fenici, R. R. andMasselli, M. (1986) Magnetocardiography: localization of accessory pathways (WPW). Proc. 8th IEEE Conf. Eng. in Med. & Biol. Soc., Fort Worth, Texas, USA, Nov. 1986, 437–438.
Fenici, R. R., Masselli, M., Lopez, L. andMelillo, G. (1987) Magnetocardiographic localization of arrythmogenic tissue. 6th Int. Conf. on Biomagnetism, Tokyo, 27th–30th Aug. 1987, 140–141.
Gotman, J. (1985) Practical use of computer-assisted EEG interpretation in epilepsy.J. Clin. Neurophysiol.2, 251–265.
Gudden, F., Hoenig, E., Reichenberger, H., Schittenhelm, R. andSchneider, S. (1989) A multi-channel system for use in biomagnetic diagnosis.Electromedica,57, 2–7.
Haemaelaeinen, M. S. andSarvas, J. (1989) Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data.IEEE Trans.,BME-36, 165–171.
Hansen, J. S., Ko, H. W., Fisher, R. S. andLitt, B. (1988) Practical limits on the biomagnetic inverse process determined fromin vitro measurements in spherical conducting volumes.Phys. in Med. & Biol.,33, 105–111.
Hari, R., Joutsiniemi, S.-L. andSarvas, J. (1988) Spatial resolution of neuromagnetic records: theoretical calculations in a spherical model.EEG & Clin. Neurophys.,71, 64–72.
Hoke, M. (1988)Springer series in brain dynamics. Springer, Berlin, 311–318.
Janday, B. S. andSwithenby, S. J. (1987) Analysis of magneto-encephalographic data using the homogeneous sphere model: empirical tests.Phys. in Med. & Biol.,32, 105–114.
Karp, P. (1981) Cardiomagnetism. InBiomagnetism.Erné, S. N., Hahlbohm, H.-D. andLübbig, H. (Eds), De Gruyter, Berlin, 219–258.
Katila, T., Maniewski, R., Maekijaervi, M., Nenonen, J. andSiltanen, P. (1987a) On the accuracy of source localization in cardiac measurements.Phys. in Med. & Biol.,32, 125–131.
Katila, T., Montonen, J., Maekijaervi, M., Nenonen, J., Raivio, M. andSiltanen, P. (1987b) Localization of the extra cardiac conduction pathway. 6th Int. Conf. on Biomagnetism, Tokyo, 27th–30th Aug. 1987, 136–137.
Kennedy, J. G., Cohen, D. andCuffin, B. N. (1987) Methods in studying MEG vs. EEG for localizing rolandic and sylvian spikes. 6th Int. Conf. on Biomagnetism, Tokyo, 27th–30th Aug. 1987, 104–105.
Meijs, J. W. H., Peters, M. J., Boom, H. B. K. andLopes da Silva, F. H. (1988) Relative influence of model assumptions and measurement procedures in the analysis of the MEG.Med. & Biol. Eng. & Comput.,26, 136–142.
Mizutani, Y. andKuriki, S. (1985) Somatically evoked magnetic fields in the vicinity of the neck.IEEE Trans.,33, 510–517.
Pagni, C. A., Ettorre, G., Infuso, L. andMarossero, F. (1964) EMG responses to capsular stimulation in the human.Experientia,20, 691–692.
Peters, M. J. andElias, P. J. H. (1988) On the magnetic field and the electrical potential generated by bioelectric sources in an anisotropic volume conductor.Med. & Biol. Eng. & Comput.,26, 617–623.
Ricci, G. B., Leoni, R., Romani, G. L., Campitelli, F., Buonomo, S. andModena, I. (1984) 3-D neuromagnetic localization of sources of interictal activity in cases of focal epilepsy. InBiomagnetism, application and theory.Weinberg, H., Stroink, G. andKatila, T. (Eds.), Pergamon Press, Proc. 5th World Conf. on Biomagnetism, Vancouver, 304–310.
Ricci, G. B., Buonomo, S., Peresson, M., Romani, G. L., Salustri, C. andModena, I. (1985) Multichannel neuromagnetic investigation of focal epilepsy.Med. & Biol. Eng. & Comput.,23, 42–43.
Romani, G. L., Williamson, S. J. andKaufman, L. (1982a) Tonotopic organization of the human auditory cortex.Science,216, 1339–1340.
Romani, G. L., Williamson, S. J., Kaufman, L. andBrenner, D. (1982b) Characterization of the human auditory cortex by the neuromagnetic method.Exp. Brain Res.,47, 381–393.
Rose, D. F., Sato, S., Smith, P. D., Porter, R. J., Theodore, W. H. andFriauf, W. (1987) Localization of magnetic interictal discharges in temporal lobe epilepsy.Ann. Neurol.,22, 348–354.
Rose, D. F., Sato, S., Smith, P. D., Friauf, W. andDucla-Soares, E. (1989) Subdural electrode as a dipole source for magnetoencephalography.EEG Clin. Neurophysiol.,72, 86–90.
Saarinen, M., Siltanen, P., Karp, P. J. andKatila, T. E. (1978) The normal magnetocardiogram.Ann. Clin. Res.,10, Suppl. 21, 1–43.
Salustri, C. andChapman, R. (1987) Pattern recognition of epileptic spikes based on correlation. Proc. 9th Ann. Conf. IEEE Eng. in Med. & Biol. Soc., Boston, Massachusetts, USA, Nov. 1987, 1258–1259.
Sato, S., Rose, D. F. andKufta, C. V. (1987) Localization of intertictal spikes using a seven channel magnetometer. 6th Int. Conf. on Biomagnetism, Tokyo, 27th–30th Aug. 1987, 100–101.
Schneider, S., Abraham-Fuchs, K., Daalmans, G., Folberth, W., Hoenig, H. E., Reichenberger, H., Röhrlein, G., Seifert, H. andWirth, A. (1989) Development and performance of a multichannel system for studies of biomagnetic signals of brain and heart. 7th Int. Conf. on Biomagnetism, New York University, 14th–18th Aug., 267–268.
Stefan, H., Burr, W. andPenin, H. (1980) Funktionelle Beziehung zwischen zentralen und peripher-motorischen Biosignalen.Z. EEG EMG,11, 28–35.
Stefan, H., Schneider, S., Abraham-Fuchs, K., Bauer, J., Feistel, H. Neubauer, U. andHuk, H. J. (1989) Application of a multichannel MEG-system in temporal lobe epilepsy. 7th Int. Conf. on Biomagnetism, New York University, 14th–18th Aug., 265–266.
Stroink, G., MacAulay, C., ten Voorde, B. J., Montague, T. J. andHoracek, B. M. (1986) High-resolution magneto-cardiographic field mapping and analysis. Proc. 8th Ann. Conf. IEEE. Eng. in Med. & Biol. Soc., Fort Worth, Texas, USA, Nov. 1986, 445.
ten Voorde, B. J., Peters, M. J., Stroink, G. andvan der Wieken, L. R. (1988) High-resolution magnetic mapping of PR-interval phenomena of normal subjects.Med. & Biol. Eng. & Comput.,26, 130–135.
Vieth, J., Schueler, P., Meyer, C., Tirilomis, T. andUllein, T. (1988) Benefit of AC- and DC-MEG measurements of focal pathological activity compared to the EEG.J. Neurol.,235, 65.
Williamson, S. J., Romani, G. L., Kaufman, L. andModena, I. (1982)Biomagnetism: an interdisciplinary approach. Plenum Press, New York.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Abraham-Fuchs, K., Härer, W., Schneider, S. et al. Pattern recognition in biomagnetic signals by spatio-temporal correlation and application to the localisation of propagating neuronal activity. Med. Biol. Eng. Comput. 28, 398–406 (1990). https://doi.org/10.1007/BF02441962
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02441962