Microprocessor-controlled contrast sensitivity measurements

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

A system is described for automatic measurement of contrast sensitivity functions (c.s.f.). The measuring technique is based on the Von Békésy tracking method. One c.s.f. can be measured in 10 min. The stimuli (sinewave gratings) are generated on a t.v. monitor screen. The stimulus parameters (spatial frequency, contrast and field size) are controlled by a microprocessor. The results are plotted in an easily interpretable from, giving the c.s.f. of both eyes together with the radio between the contrast sensitivity of the two eyes. Clinical measurements on amblyopic patients are described by way of illustration of the application of the system.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Békésy, G. von, (1947) A new audiometer.Acta Otolaryngol. (Stockholm),35, 411–422.

    Google Scholar 

  • Campbell, F. W. andRobson, J. G. (1968) Application of Fourier analysis to the visibility of gratings.J. Physiol. Lond.,197, 551–556.

    Google Scholar 

  • Hagemans, K. H. andWildt, G. J. van der (1978a) A study on the usefulness of contrast detection in the diagnosis of amblyopia.Am. J. Ophthal. (submitted for publication).

  • Hagemans, K. H. andWildt, G. J. van der (1978b) The influence of the stimulus width on the contrast sensitivity function in amblyopiaAm. J. Opthal. (submitted for publication).

  • Hess, R. F. andHowell, E. R. (1977) The threshold contrast sensitivity function in strabismis amblyopia: evidence for a two-type classification.Vision Res.,17, 1049–1055.

    Article  Google Scholar 

  • Savoy, R. L. andMcCann, J. J. (1975) Visibility of low-spatial frequency sine-wave targets: dependence on number of cycles.J. Opt. Soc. Am.,65, 343–350.

    Google Scholar 

  • Seculer, R. andTynan, P. (1977) Rapid measurement of contrast-sensitivity functions.Am. J. Optom. Physiol. Optics,54, 573–575.

    Google Scholar 

  • Sjöstrand, J. (1979) Contrast sensitivity in amblyopia. A preliminary report.J. Metabol. Ophthal. (to be published).

  • Wildt, G. J. van der, Keemink, C. J. andBrink, G. van den (1976) Gradient detection and contrast transfer by the human eye.Vision Res.,16, 1047–1053.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Keemink, C.J., van der Wildt, G.J. & van Deursen, J.B.P. Microprocessor-controlled contrast sensitivity measurements. Med. Biol. Eng. Comput. 17, 371–378 (1979). https://doi.org/10.1007/BF02443825

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02443825

Keywords

Navigation