Air oxidation of aqueous cyanides in a countercurrent fixed bed reactor

  • Published:
Korean Journal of Chemical Engineering Aims and scope Submit manuscript

Abstract

This study was conducted to discuss the removal of cyanides from water by air oxidation. Experiments were carried out in a countercurrent fixed bed reactor for three different values of temperature, concentration, gas and liquid flow rates. It was operated at pH 12 by using delrin (formaldehyde polymer) as packing material. Effects of some operating parameters on the conversion were studied, and it was observed that the conversion percent increased by increasing temperature and decreasing gas and liquid flow rates. Effect of concentration was not steady. A conversion of 89% was achieved under optimum conditions while it ranges from 44 to 79% at room temperature.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Alam, M. and Kamath, S., “Cyanide Destruction in Molten Carbonate Bath: Melt and Gas Analyses,”Em. Sci. Tech.,32(24), 3986 (1998).

    Article  CAS  Google Scholar 

  • Alicilar, A., Bicer, A. and Murathan, A., “The Relation Between Wetting Efficiency and Liquid Holdup in Packed Columns,”Chem. Eng. Comm.,128, 95 (1994).

    Article  Google Scholar 

  • Basheer, S., Kut, ö. M., Prenosil, J. E. and Bourne, J. R., “Development of an Enzyme Membrane Reactor for Treatment of Cyanide-Containing Wastewaters from the Food Industry”Biotech. Bioeng.,41, 465 (1993).

    Article  CAS  Google Scholar 

  • Borbely, G. J., Cliff, C, Devuyst, E. A., Ettel, V. A., Mosoiu, M. A. and Schitka, K. J., US Patent 4, 537686 (1985).

  • Devuyst, E. A., Robbins, G., Vergunst, R., Tandi, B. and Iamarino, P. F., “Inco’s Cyanide Removal Technology Working Well,”Mining Eng.,2, 205 (1991).

    Google Scholar 

  • Gaudy, A. F., Gaudy, Jr. E. T, Feng, Y. J. and Brueggemann, Y. G., “Treatment of Cyanide Waste by the Extended Aeration Process”JWPCF,54(2), 153 (1982).

    CAS  Google Scholar 

  • Gurol, M. D. and Bremen, W M., “Kinetics and Mechanism of Ozonation of Free Cyanide Species in Water,”Em. Sci. Tech.,19(9), 804 (1985).

    Article  CAS  Google Scholar 

  • Ho, S. P., Wang, Y Y. and Wan, C. C, “Electrolytic Decomposition of Cyanide Effluent with an Electrochemical Reactor Packed with Stainless Steel Fibre,”Wat. Res.,24(11), 1317 (1990).

    Article  CAS  Google Scholar 

  • Horowitz, G I., Martinez, O., Cukierman, A. L. and Cassanello, M. C, “Ethanol Oxidation in a Trickle Bed Reactor using a Hydrophobie Catalyst Effect of Dilution with Hydrophilic Particles,”Catal. Today,64(3-4), 347 (2001).

    Article  CAS  Google Scholar 

  • Kim, S. J., Hwang, K. R., Cho, S. Y. and Moon, H., “Simultaneous Removal of Cyanide and Copper Ions in a Semi-fluidized Ion Exchanger Bed,”Korean J. Chem. Eng.,16, 664 (1999).

    CAS  Google Scholar 

  • Kömürcü, M., “Oxidation of Cyanide in Water in Packed Column,” M.S. Thesis, Gazi University, Ankara, Turkey (1999).

    Google Scholar 

  • Matatov, M. Y. and Sheintuch, M., “Catalytic Abatement of Water Pollutants,”Ind. Eng. Chem. Res.,37(2), 309 (1998).

    Article  Google Scholar 

  • Pak, D. and Chang, W, “Oxidation of Aqueous Cyanide Solution using Hydrogen Peroxide in the Presence of Heterogeneous Catalyst,”Env. Tech.,18(5), 557 (1997).

    Article  CAS  Google Scholar 

  • Pamuk, V., Yilmaz, M. and Alicilar, A., “The Preparation of D-Glucaric Acid by Oxidation of Molasses in Packed Beds,”J. Chem. Tech. Biotech.,76(2), 186 (2001).

    Article  CAS  Google Scholar 

  • Park, Y H., Kim, S. J. and Kang, S. C, “Effect of the Reaction Bath Temperature in a Fixed-Bed Reactor for Oxidation of o-Xylene over V2O5/TiO2 Catalysts,”Korean J. Chem. Eng.,17, 81 (2000).

    CAS  Google Scholar 

  • Sharma, V. K., Rivera, W, Smith, J. D. and Brandon, B., “Ferrate (IV) Oxidation of Aqueous Cyanide,”Em. Sci. Tech.,32(17), 2608 (1998).

    Article  CAS  Google Scholar 

  • Walsht, F. and Wilson, G., “The Electrolytic Removal of Gold from Spent Electroplating Liquors,”Trans. IMF,64,55 (1986).

    Google Scholar 

  • Xiao, Q., Cheng, Z. M., Jiang, Z. X., Anter, A. M. and Yuan, W. K., “Hydrodynamic Behavior of a Trickle Bed Reactor Under Forced Pulsing Flow,”Chem. Eng. Sci.,56,1189 (2001).

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ahmet Alicilar.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Alicilar, A., Kömürcü, M. & Murathan, A. Air oxidation of aqueous cyanides in a countercurrent fixed bed reactor. Korean J. Chem. Eng. 19, 273–276 (2002). https://doi.org/10.1007/BF02698413

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02698413

Key words

Navigation