Abstract
This study was conducted to discuss the removal of cyanides from water by air oxidation. Experiments were carried out in a countercurrent fixed bed reactor for three different values of temperature, concentration, gas and liquid flow rates. It was operated at pH 12 by using delrin (formaldehyde polymer) as packing material. Effects of some operating parameters on the conversion were studied, and it was observed that the conversion percent increased by increasing temperature and decreasing gas and liquid flow rates. Effect of concentration was not steady. A conversion of 89% was achieved under optimum conditions while it ranges from 44 to 79% at room temperature.
Similar content being viewed by others
References
Alam, M. and Kamath, S., “Cyanide Destruction in Molten Carbonate Bath: Melt and Gas Analyses,”Em. Sci. Tech.,32(24), 3986 (1998).
Alicilar, A., Bicer, A. and Murathan, A., “The Relation Between Wetting Efficiency and Liquid Holdup in Packed Columns,”Chem. Eng. Comm.,128, 95 (1994).
Basheer, S., Kut, ö. M., Prenosil, J. E. and Bourne, J. R., “Development of an Enzyme Membrane Reactor for Treatment of Cyanide-Containing Wastewaters from the Food Industry”Biotech. Bioeng.,41, 465 (1993).
Borbely, G. J., Cliff, C, Devuyst, E. A., Ettel, V. A., Mosoiu, M. A. and Schitka, K. J., US Patent 4, 537686 (1985).
Devuyst, E. A., Robbins, G., Vergunst, R., Tandi, B. and Iamarino, P. F., “Inco’s Cyanide Removal Technology Working Well,”Mining Eng.,2, 205 (1991).
Gaudy, A. F., Gaudy, Jr. E. T, Feng, Y. J. and Brueggemann, Y. G., “Treatment of Cyanide Waste by the Extended Aeration Process”JWPCF,54(2), 153 (1982).
Gurol, M. D. and Bremen, W M., “Kinetics and Mechanism of Ozonation of Free Cyanide Species in Water,”Em. Sci. Tech.,19(9), 804 (1985).
Ho, S. P., Wang, Y Y. and Wan, C. C, “Electrolytic Decomposition of Cyanide Effluent with an Electrochemical Reactor Packed with Stainless Steel Fibre,”Wat. Res.,24(11), 1317 (1990).
Horowitz, G I., Martinez, O., Cukierman, A. L. and Cassanello, M. C, “Ethanol Oxidation in a Trickle Bed Reactor using a Hydrophobie Catalyst Effect of Dilution with Hydrophilic Particles,”Catal. Today,64(3-4), 347 (2001).
Kim, S. J., Hwang, K. R., Cho, S. Y. and Moon, H., “Simultaneous Removal of Cyanide and Copper Ions in a Semi-fluidized Ion Exchanger Bed,”Korean J. Chem. Eng.,16, 664 (1999).
Kömürcü, M., “Oxidation of Cyanide in Water in Packed Column,” M.S. Thesis, Gazi University, Ankara, Turkey (1999).
Matatov, M. Y. and Sheintuch, M., “Catalytic Abatement of Water Pollutants,”Ind. Eng. Chem. Res.,37(2), 309 (1998).
Pak, D. and Chang, W, “Oxidation of Aqueous Cyanide Solution using Hydrogen Peroxide in the Presence of Heterogeneous Catalyst,”Env. Tech.,18(5), 557 (1997).
Pamuk, V., Yilmaz, M. and Alicilar, A., “The Preparation of D-Glucaric Acid by Oxidation of Molasses in Packed Beds,”J. Chem. Tech. Biotech.,76(2), 186 (2001).
Park, Y H., Kim, S. J. and Kang, S. C, “Effect of the Reaction Bath Temperature in a Fixed-Bed Reactor for Oxidation of o-Xylene over V2O5/TiO2 Catalysts,”Korean J. Chem. Eng.,17, 81 (2000).
Sharma, V. K., Rivera, W, Smith, J. D. and Brandon, B., “Ferrate (IV) Oxidation of Aqueous Cyanide,”Em. Sci. Tech.,32(17), 2608 (1998).
Walsht, F. and Wilson, G., “The Electrolytic Removal of Gold from Spent Electroplating Liquors,”Trans. IMF,64,55 (1986).
Xiao, Q., Cheng, Z. M., Jiang, Z. X., Anter, A. M. and Yuan, W. K., “Hydrodynamic Behavior of a Trickle Bed Reactor Under Forced Pulsing Flow,”Chem. Eng. Sci.,56,1189 (2001).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Alicilar, A., Kömürcü, M. & Murathan, A. Air oxidation of aqueous cyanides in a countercurrent fixed bed reactor. Korean J. Chem. Eng. 19, 273–276 (2002). https://doi.org/10.1007/BF02698413
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02698413