Abstract
The main sources of the refrigerant-induced noise can be classified 2 types according to its characteristics. One is due to the cyclic characteristics such as quality, velocity of the refrigerant, pressure drop and mass flow rate. The other is due to the structural characteristics such as distributed path pipe layout, distributor and expansion device. In this paper, the effects of cycle characteristics on the noise of multi-type system air-conditioner are investigated experimentally. In the indoor unit of multi-type air-conditioner, the variation of noise is examined when the in-flowing and out-flowing refrigerant to the indoor unit are 2-phase state according to its cycle control. And several factors are recommended in order to reduce the refrigerant-induced noise of the air-conditioner.
Similar content being viewed by others
References
Arora, C. P., 2000, “Refrigeration and Air Conditioning,” McGraw-Hill.
Cjoi, J. M. and Kim, Y. C., 2005, “Perfomance of Short Tube Orifices Using R-410A Near the Critical Region,”Korean Journal of Air-conditioning and Refrigeration Engineers, Vol. 17, No. 12, pp. 1106–1112.
Gian Piero Celata, 1997, “Experimental Evaluation of the Onset of Subcooled Flow Boiling at High Liquid Velocity and Subcooling,”International Journal of Multiphase Flow, Vol. 40, No. 12, pp. 2879–2885.
Han, H. S. and Shigeo Aoyama, 2006, “Analyzing for Refrigerant-Induced Noise for Split Type air Conditioner Indoor Unit,”KSNVE, Vol. 16, No. 3, pp. 240–246.
Hirakuni Satoshi, 2004, “Noise Reduction Technology caused by refrigerant Two-Phase Flow for Room Airconditioner,”Japanese J. Multiphase Flow, Vol. 18, No. 1, pp. 23–30.
Hirakuni Sator, Smida Yoshihiro, and Yamamoto Hideo, 1998, “Study of Noise Reduction of Refrigerant for Capillary Tube in the Refrigerator,”32th Conference Journal of Refrigeration and Air-conditioning Association, Vol. 4, pp. 22–24.
Jang, H. K., Kim, S. H., Rhee, J. H. and Yang, J. R., 1999, “Reduction of Flow-Induced Vibration in the Heat Exchanger,”Journal of KSNVE, Vol. 9, No. 6, pp. 1200–1209.
Masella, J. M., 1998, “Transient Simulation of Two-Phase Flows in Pipes,”International Journal of Multiphase Flow, Vol. 24, pp. 739–755.
Park, J. H., 1996, “Definition and Improvement of the Sound which was Generated by Bubbles at the Accumulator of the Evaporator,” KSNVE, Vol. 6, No. 4, pp. 513–519.
Seo, Young-Soo and Jeong, Weui-Bong, 2003, “Finite Element Vibration Analysis of Cylindrical Shells with Internal Fluid Flow,”2003 Spring Conference Journal of KSNVE, pp. 911–916.
Tatsumi Kannon, 1997, “Study on Noise Caused by Slug Flow through a Capillary Tube,”JSME, Vol. 63, No. 611, pp. 2392–2397.
Tomomi Umeda, 1993, “Reduction of Noise Caused by Gas-Liquid Two-Phase Refrigerant Flow through an Expansion Valve,”JSME, Vol. 59, No. 557, pp. 243–248.
Whalley, P. B., 1999, “Two Phase Flow and Heat Transfer,” Oxford University Press.
Willam S. Janna, 1993, “Design of Fluid Thermal Systems,” PWS-Kent Publishing Company.
Yang, C. Y., 2001, “Flow Pattern of Air-Water and Two-phase R-134a in Small Circular Tubes,”International Journal of Multiphase Flow, Vol. 27, pp. 1163–1177.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jeong, W.B., Han, H.S., Mo, J.Y. et al. Experimental study of the effects of the cycle characteristics on the refrigerant-induced noise in system air-conditioner. J Mech Sci Technol 21, 1112–1119 (2007). https://doi.org/10.1007/BF03027661
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03027661