Abstract
Shunt active power filters (SAPFs) have been widely used to improve power quality of the grid by mitigating harmonics injected from nonlinear loads. This paper presents a new method for improving the performance of SAPFs using neutral-point-clamped (NPC) three-level inverters. NPC three-level inverters often suffer excessive voltage fluctuations at the neutral-point of DC-link capacitors, which may damage switching devices and cause additional high harmonic distortion of the output voltage. In order to solve the problem, two compensating schemes are proposed to restrict voltage fluctuation in the inverters. The first is voltage dependent, adopting a voltage compensation method, while the second is current dependent, using a current compensation method. The paper describes the respective circuit architectures and principles of operation. Corresponding models are mathematically formulated and evaluated under typical balanced and unbalanced working load conditions. The results show that both schemes are able to alleviate considerably voltage oscillations and hence harmonic distortions, and the current-compensated NPC inverter outperforms the voltage-compensated NPC inverter. Consequently, it is shown that the proposed approaches are effective and feasible for improving power quality of the grid when connected to nonlinear loads.
Similar content being viewed by others
Abbreviations
- SAPF:
-
Shunt active power filters
- NPC:
-
Neutral point clamped
- DG:
-
Distributed generation
- PV:
-
Photovoltaics
- THD:
-
Total harmonic distortion
- SVPWM:
-
Space voltage vector pulse-width modulation
- VNPCI:
-
Voltage-dependent NPC three-level inverter
- CNPCI:
-
Current-controlled NPC three-level inverter
- IGBT:
-
Insulated gate bipolar transistor
- \(u_\mathrm{sa}, u_\mathrm{sb}, u_\mathrm{sc}\) :
-
Three-phase alternating-current supply
- \(i_\mathrm{sa}, i_\mathrm{sb}, i_\mathrm{sc}\) :
-
Grid currents
- \(i_\mathrm{La}, i_\mathrm{Lb}, i_\mathrm{Lc}\) :
-
Load currents
- \(i_\mathrm{ca}, i_\mathrm{cb}, i_\mathrm{cc}\) :
-
Compensation currents provided by the SAPF
- \(u_\mathrm{o}\) :
-
Neutral-point voltage of the three-phase bridge arm
- \(u_\mathrm{N}\) :
-
Neutral-point voltage of the DC-link capacitors
- \(u_\mathrm{c}\) :
-
Voltage of the primary side of the transformer
- \(u_\mathrm{b}\) :
-
Compensating voltage
- \(u_\mathrm{s}\) :
-
DC-link voltage applied across the capacitors
- \(S_{1}, S_{2}, S_{3}, S_{4}\) :
-
IGBT power switches
- T :
-
Coupling transformer
- L, \({C}_{f}\) :
-
LC filter
- \(u_\mathrm{dc}\) :
-
DC voltage applied to the single-phase full-bridge inverter
- \(u_{i}\) :
-
Voltage output of the single-phase inverter
- \(i_{1}\) :
-
Current through the filter inductor
- \(i_{2}\) :
-
Transformer primary side current
- \(i_\mathrm{cf}\) :
-
Current through the filter capacitor
- \({D}_{1}\) :
-
Diode used to prevent reverse current flow
- \({L}_{2}, {C}_{3}\) :
-
LC filter
- \(u_\mathrm{dc1}\) :
-
Voltage input of the boost DC/DC converter
- \(u_\mathrm{dc2}\) :
-
Voltage output of the boost DC/DC convertor
- \(i_{\mathrm{c3(off})}\) :
-
Current in capacitor \({C}_{3}\) when switching device \({S}_{5}\) is turned off
- \(i_{3}\) :
-
Current in the inductor \({L}_{1}\)
- \(i_{4}\) :
-
Compensating current
- \(u_{\mathrm{L1(off})}\) :
-
Voltage across the inductor \({L}_{1}\) when switching device \({S}_{5}\) is turned off
- \(u_{\mathrm{L1(on})}\) :
-
Voltage across inductor \({L}_{1}\) when switch \({S}_{5}\) is turned on
- D :
-
Duty cycle of the switching device \({S}_{5}\)
- \(K_{p}, K_{i}\) :
-
Parameters of the PI controller
References
Pepermans G, Driesen J, Haeseldonckx D, Belmans R, D’haeseleer W (2005) Distributed generation: definition, benefits and issues. Energy Policy 33:787–798
Pouresmaeil E, Montesinos-Miracle D, Gomis-Bellmunt O, Sudrià-Andreu A (2011) Instantaneous active and reactive current control technique of shunt active power filter based on the three-level NPC inverter. Int Trans Electric Energy Syst 21:2007–2022
Allmeling JH (2004) A control structure for fast harmonics compensation in active filters. IEEE Trans Power Electron 19(2):508–514
Liang W, Donglai Z, Yi W, Bin W, Hussain SA (2016) Power and voltage balance control of a novel three-phase solid-state transformer using multilevel cascaded H-bridge inverters for microgrid applications. IEEE Trans Power Electron 31(4):3289–3301
Roodsari BN, Nowicki EP (2013) Fast space vector modulation algorithm for multilevel inverters and its extension for operation of the cascaded H-bridge inverter with non-constant DC sources. IET Power Electron 6:1288–1298
Ke M, Frede B (2012) The impact of power switching devices on the thermal performance of a 10 MW wind power NPC converter. Energies 5(7):2559–2577
Muyeen SM, Takahashi R, Tamura J (2010) Wind power and hydrogen generation system with cooperatively controlled three-level NPC-VSC based energy capacitor. Int Trans Electric Energy Syst 20:1071–1081
Zaveri T, Bhalja BR, Zaveri N (2012) Load compensation using DSTATCOM in three-phase, three-wire distribution system under various source voltage and delta connected load conditions. Int J Electric Power Energy Syst 41:34–43
Saad S, Zellouma L (2009) Fuzzy logic controller for three-level shunt active filter compensating harmonics and reactive power. Electric Power Syst Res 79:1337–1341
Celanovic N, Boroyevich D (2000) A comprehensive study of neutral-point voltage balancing problem in three-level neutral-point-clamped voltage source PWM inverters. IEEE Trans Power Electron 15:242–249
Ui-Min C, Frede B, Kyo-Beum L (2015) Method to minimize the low-frequency neutral-point voltage oscillations with time-offset injection for neutral-point-clamped inverters. IEEE Trans Ind Appl 51:1678–1691
Rodriguez J, Bernet S (2010) A survey on neutral-point-clamped inverters. IEEE Trans Ind Electron 57:2219–2230
Helle L, Nielsen SM, Enjeti P (2002) Generalized discontinuous DC-link balancing modulation strategy for three-level inverters. In: Power conversion conference, Osaka, Japan, vol 2, pp 359–366
Yazdani A, Iravani R (2005) Generalized state-space averaged model of the three-level NPC converter for systematic DC-voltage-balancer and current-controller design. IEEE Trans Power Deliv 20:1105–1114
Zaragoza J, Pou J, Ceballos S, Robles E, Jaen C (2009) Voltage-balance compensator for a carrier-based modulation in the neutral-point-clamped converter. IEEE Trans Ind Electron 56:305–314
Ui-Min C, June-Seok L, Kyo-Beum L (2014) New modulation strategy to balance the neutral-point voltage for three-level neutral-clamped inverter systems. IEEE Trans Energy Convers 29:91–100
Pulikanti SR, Dahidah SA (2011) Voltage balancing control of three-level active NPC converter using SHE-PWM. IEEE Trans Power Deliv 26:258–267
Ghennam T, Berkouk EM, Francois B (2010) A novel space–vector current control based on circular hysteresis areas of a three-phase neutral point-clamped inverter. IEEE Trans Ind Electron 57:2669–2678
Lewicki A, Krzeminski Z, Abu-Rub H (2011) Space–vector pulse width modulation for three-level NPC converter with the neutral point voltage control. IEEE Trans Ind Electron 58:5076–5086
Xiyou C, Kazerani M (2006) Space vector modulation control of an AC–DC–AC converter with a front-end diode rectifier and reduced dc-link capacitor. IEEE Trans Power Electron 21:1470–1478
Huibin Z, Finney SJ, Massoud A, Williams BW (2008) An SVM algorithm to balance the capacitor voltages of the three-level NPC active power filter. IEEE Trans Power Electron 23:2694–2702
Bouhali O, Francois B, Berkouk EM (2007) DC link capacitor voltage balancing in a three-phase diode clamped inverter controlled by a direct space vector of line-to-line voltages. IEEE Trans Power Electron 22:1636–1648
Dongsheng Z, Didier GR (2001) Experimental comparisons of space vector neutral point balancing strategies for three-level topology. IEEE Trans Power Electron 16:872–879
Nikola C, Dushan B (2000) A comprehensive study of neutral-point voltage balancing problem in three-level neutral-point-clamped voltage source PWM inverters. IEEE Trans Power Electron 15:242–249
Sergio B, Josep B, Dushan B, Sergio S (2004) The nearest three virtual space vector PWM–A modulation for the comprehensive neutral-point balancing in the three-level NPC inverter. IEEE Power Electron Lett 2:11–15
Mishra MK, Joshi A, Ghosh A (2003) Control schemes for equalization of capacitor voltages in neutral clamped shunt compensator. IEEE Trans Power Deliv 18:538–544
Yong L, Yanjian P, Fang L, Denis S, Daniil P, Chonggan L, Long L, Yijia C (2016) A controllably inductive filtering method with transformer-integrated linear reactor for power quality improvement of shipboard power system. In: IEEE transactions on power delivery
Shengwei L, Yongli L, Jingliao S, Qiang J, Xuguang L (2009) A novel control algorithm for inverter-based distributed generation in unbalanced three phase power systems, In: International conference on sustainable power generation and supply, Nanjing, China, pp 1–6
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Qian, P., Ma, X., Liu, G. et al. Reducing neutral-point voltage fluctuation in NPC three-level active power filters. Electr Eng 100, 721–732 (2018). https://doi.org/10.1007/s00202-017-0538-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00202-017-0538-y