Abstract
Synthetic pyrethroids fragment extensively under electron ionization (EI) conditions to give low mass ions, most of them with the same m/z ratios. This fragmentation is primarily due to the labile ester linkage found in these compounds. In this research we established the best gas chromatography (GC) conditions in the EI mode that served as a benchmark in the development of a chemical ionization (CI) protocol for ten selected synthetic pyrethroids. Based on proton affinity data, several reagent gases were evaluated in the positive CI ionization mode. Methanol was found to produce higher average ion counts relative to the other gases evaluated, which led to the development of an optimized method consisting of selective ejection chemical ionization (SECI) and MS/MS. Standard stainless steel ion trap electrodes produced significant degradation of chromatographic performance on late eluting compounds, which was attributed to electrode surface chemistry. A dramatic improvement in signal-to-noise (S/N) ratios was observed when the chromatographically inert Silcosteel® coated electrodes were used. The resulting method, that has significant S/N ratio improvements resulting from a combination of septum programmable injections (SPI), optimized CI and inert Silcosteel®-coated electrodes, was used to determine instrument detection limits.
Similar content being viewed by others
References
Zong-Mao C, Yun-Hao W (1996) J Chromatogr A 754:367–395
Class TJ (1991) J High Res Chromatogr 14:446–450
Naumann K (1990) Synthetic pyrethroid insecticides: chemistry and patents, vol 3. Springer, Berlin Heidelberg New York
Blaβ W, Weiler EW (1990) Chemistry of plant protection, vol 3. Springer, Berlin Heildelberg New York
Moraghan JJ, Lee WT, Fleet IA (1993) Org Mass Spectrom 28:626–634
Holmstead RL, Soderlund DM (1977) J AOAC 60(3):685–689
Wei LY (1991) Pestic Sci 32:141–145
Brown RT, Pfeil RM, Eller IK, Argauer JR (1997) J Agr Food Chem 45:180–184
Ramesh A, Ravi PE (2004) J Chromatogr B 802:371–376
Schettgen T, Koch HM, Drexler H, Angerer J (2002) J Chromatogr B 778:121–130
Ahmed EF (2001) TrAC–Trends Anal Chem 20(11):649–661
Barr DB, Needham LL (2002) J Chromatogr B 778(1–2):5–9
Kocourek V, Hajölov J, Holadov K, Poustka J (1998) J Chromatogr A 800(2):297–302
Pang G et al (2000) J Chromatogr A 882(1–2):231–238
Lopez-Lopez T, Gil-Garcia MD, Martinez-Vidal JL, Martinez-Galera M (2001) Anal Chim Acta 447(1–2):101–111
Elflein L, Berger-Preiss E, Preiss A, Elend M, Levsen K, Wηnsch G (2003) J Chromatogr B 795:195–207
Olsson AO, Baker SE, Nguyen JV, Romanoff LC, Udunka SO, Walker RD, Flemmen KL, Barr DB (2004) Anal Chem 76(9):2453–2461
Liu WP, Gan JJ (2004) J Agr Food Chem 52(4):736–741
Lee S, Gan J, Kabashima J (2002) J Agr Food Chem 50(25):7194–7198
Bauerle GF Jr, Ray KL, Brodbelt JS (1995) Anal Chim Acta 317:137–148
Varian Chromatography Systems (1996) Advanced MS Techniques Saturn GC/MS 2000. Varian Associates, Palo Alto, CA, pp 17–31
Harrison GE (1992) Chemical ionization mass spectrometry. CRC, Boca Raton, FL, pp 36–37, 72
Croley TR, Zemribo R, Lynn BC Jr (1999) Int J Mass Spectrom 190/191:265–279
Kimbrough DE, Wakakuwa J (1993) Environ Sci Technol 27(13):2692–2699
Acknowledgements
The author acknowledges the support of the Mississippi State Chemical Laboratory in this work. Financial support was obtained from the Fulbright Foundation and the Department of Chemistry of Mississippi State University.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sichilongo, K. Enhanced signal generation for use in the analysis of synthetic pyrethroids using chemical ionization tandem quadrupole ion trap mass spectrometry. Anal Bioanal Chem 380, 942–949 (2004). https://doi.org/10.1007/s00216-004-2864-y
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-004-2864-y