Skip to main content
Log in

Evaluation of sample preparation methods for elastomer digestion for further halogens determination

  • Technical Note
  • Published:
Analytical and Bioanalytical Chemistry Aims and scope Submit manuscript

Abstract

In this work, three sample preparation methods were evaluated for further halogen determination in elastomers containing high concentrations of carbon black. Samples of nitrile-butadiene rubber, styrene-butadiene rubber, and ethylene-propylene-diene monomer elastomers were decomposed using oxygen flask combustion and microwave-induced combustion (MIC) for further Br and Cl determination by ion chromatography (IC), inductively coupled plasma optical emission spectrometry (ICP OES), and inductively coupled plasma mass spectrometry (ICP-MS). Extraction assisted by microwave radiation in closed vessels was also evaluated using water or alkaline solution. Digestion by MIC was carried out using 50 mmol l−1 (NH4)2CO3 as the absorbing solution. The effect of the reflux step was also evaluated. Accuracy was evaluated using certified reference materials with polymeric matrix composition and by comparison of results using neutron activation analysis. Agreement for Br and Cl was better than 95% by MIC using 5 min of reflux, and no statistical difference was found using IC, ICP OES, and ICP-MS for determination of both analytes. For MIC, the relative standard deviation (RSD) was lower than 5%. Using extraction in closed vessels, a high amount of residues was observed, and recoveries were lower than 45% for both analytes. For oxygen flask combustion, the agreement was similar using MIC but RSD was higher (20%). The residual carbon content, an important parameter used to evaluate the digestion efficiency, was always below 1% for MIC. Using MIC, it was possible to digest elastomers with high efficiency, resulting in a single solution suitable for halogen determination by different techniques.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Mark JE, Abou-Hussein R, Sen TZ, Kloczkowski A (2005) Some simulations on filler reinforcement in elastomers. Polymer 46:8894–8904

    Article  CAS  Google Scholar 

  2. Luo H, Klüppel M, Schneider H (2004) Study of filled SBR elastomers using NMR and mechanical measurements. Macromolecules 37:8000–8009

    Article  CAS  Google Scholar 

  3. Billmeyer FW (1984) Textbook of polymer science, 3rd edn. Wiley, New York

    Google Scholar 

  4. Laouti F, Bonnaud L, Alexandre M, Lopez-Cuesta J-M, Dubois Ph (2009) New prospects in flame retardant polymer materials: from fundamentals to nanocomposites. Mat Sci Eng R 63:100–125

    Article  CAS  Google Scholar 

  5. Rahman F, Langford KH, Scrimshaw MD, Lester JN (2001) Polybrominated diphenyl ether (PBDE) flame retardants. Sci Total Environ 275:1–17

    Article  CAS  Google Scholar 

  6. Kemmlein S, Herzke D, Law RJ (2009) Brominated flame retardants in the European chemicals policy of REACH—regulation and determination in materials. J Chromatogr A 1216:320–333

    Article  CAS  Google Scholar 

  7. Kemmlein S, Herzke D, Law RJ (2003) BFR-governmental testing programme. Environ Int 29:781–792

    Article  CAS  Google Scholar 

  8. Directive 2002/96/EC of the European Parliament and of the Council of January 27 (2003) On waste electrical and electronic equipment (WEEE). Off J Eur Comm L037:24–38

    Google Scholar 

  9. Directive 2002/95/EC of the European Parliament and of the Council of January 27 (2003) On the restriction of the use of certain hazardous substances in electrical and electronic equipments (RoHS). Off J Eur Comm L037:19–23

    Google Scholar 

  10. Lamberty A, Van Borm W, Quevauviller P (2001) Collaborative study to improve the quality control of trace element determination in polymers. Part 2. Certification of polyethylene reference materials (CRMs 680 and 681) for As, Br, Cd, Cl, Cr, Hg, Pb and S content. Fresenius’ J Anal Chem 370:811–818

    Article  CAS  Google Scholar 

  11. Österlund H, Rodushkin I, Ylinenjärvi K, Baxter DC (2009) Determination of total chlorine and bromine in solid wastes by sintering and inductively coupled plasma-sector field mass spectrometry. Waste Manage 29:1258–1264

    Article  CAS  Google Scholar 

  12. Dimitrakakis E, Janz A, Bilitewski B, Gidarakos E (2009) Determination of heavy metals and halogens in plastics from electric and electronic waste. Waste Manage 29:2700–2706

    Article  CAS  Google Scholar 

  13. Mester Z, Sturgeon R (2003) Sample preparation for trace analysis, vol XLI. Elsevier, Amsterdam

    Google Scholar 

  14. Todolí JL, Mermet J-M (1999) Acid interferences in atomic spectrometry: analyte signal effects and subsequent reduction. Spectrochim Acta Part B 54:895–929

    Article  Google Scholar 

  15. Kaiser E, Rohrer JS, Jensen D (2001) Determination of trace anions in high-nitrate matrices by ion chromatography. J Chromatogr A 920:127–133

    Article  CAS  Google Scholar 

  16. Pereira JSF, Mello PA, Moraes DP, Duarte FA, Dressler VL, Knapp G, Flores EMM (2009) Chlorine and sulfur determination in extra-heavy crude oil by inductively coupled plasma optical emission spectrometry after microwave-induced combustion. Spectrochim Acta Part B 64:554–558

    Article  CAS  Google Scholar 

  17. Besecker KD, Rhoades CD, Jones BT, Barnes KW (1998) Closed-vessel nitric acid microwave digestion of polymers. At Spectrosc 19:55–59

    CAS  Google Scholar 

  18. Besecker KD, Rhoades CD, Jones BT, Barnes KW (1998) A simple closed-vessel nitric acid digestion method for a polyethylene/polypropylene polymer blend. At Spectrosc 19:193–197

    CAS  Google Scholar 

  19. Sakurai H, Noro J, Kawase A, Fujinami M, Oguma K (2006) Digestion of plastic materials for the determination of toxic metals with a microwave oven for household use. Anal Sci 22:225–228

    Article  CAS  Google Scholar 

  20. Zischka M, Kettisch P, Kainrath P (1998) Microwave-assisted digestion of plastic scrap: basic considerations and chemical approach. At Spectrosc 19:223–227

    CAS  Google Scholar 

  21. Ranz A, Maier E, Trampitsch C, Lankmayr E (2008) Microwave-assisted extraction of decabromodiphenylether from polymers. Talanta 76:102–106

    Article  CAS  Google Scholar 

  22. Annual Book of ASTM Standards (2003) Standard practice for rubber-determination of bromine in the presence of chlorine by oxygen combustion, D 3566. ASTM International, West Conshohocken

    Google Scholar 

  23. Haslam J, Hamilton JB, Squirrell DCM (1960) Application of the oxygen combustion method to the determination of chlorine in polymers, plasticisers and organic compounds. J Appl Chem 10:97–100

    Article  CAS  Google Scholar 

  24. Flores EMM, Barin JS, Mesko MF, Knapp G (2007) Sample preparation techniques based on combustion reactions in closed vessels—a brief overview and recent applications. Spectrochim Acta Part B 62:1051–1064

    Article  CAS  Google Scholar 

  25. Truscott ED (1970) Determination of chlorine in a polyvinyl chlorine matrix using the Schöniger oxygen flask and atomic absorption spectrometry. Anal Chem 42:1657

    Article  CAS  Google Scholar 

  26. Duarte FA, Pereira JSF, Barin JS, Mesko MF, Dressler VL, Flores EMM, Knapp G (2009) Seafood digestion by microwave-induced combustion for total arsenic determination by atomic spectrometry techniques with hydride generation. J Anal At Spectrom 24:224–227

    Article  CAS  Google Scholar 

  27. Flores EMM, Mesko MF, Moraes DP, Pereira JSF, Mello PA, Barin JS, Knapp G (2008) Determination of halogens in coal after digestion using the microwave-induced combustion technique. Anal Chem 80:1865–1870

    Article  CAS  Google Scholar 

  28. Flores EMM, Barin JS, Paniz JNG, Medeiros JA, Knapp G (2004) Microwave-assisted sample combustion: a technique for sample preparation in trace element determination. Anal Chem 76:3525–3529

    Article  CAS  Google Scholar 

  29. Mesko MF, Moraes DP, Barin JS, Dressler VL, Knapp G, Flores EMM (2006) Digestion of biological materials using the microwave-assisted sample combustion technique. Microchem J 82:183–188

    Article  CAS  Google Scholar 

  30. Pereira JSF, Diehl LO, Duarte FA, Santos MFP, Guimarães RCL, Dressler VL, Flores EMM (2008) Chloride determination by ion chromatography in petroleum coke after digestion by microwave-induced combustion. J Chromatogr A 1213:249–252

    Article  CAS  Google Scholar 

  31. Mello PA, Giesbrecht CK, Alencar MS, Moreira EM, Paniz JNG, Dressler VL, Flores EMM (2008) Determination of sulfur in petroleum coke combining closed vessels microwave-induced combustion and inductively coupled plasma-optical emission spectrometry. Anal Lett 41:1623–1632

    Article  CAS  Google Scholar 

  32. Mello PA, Pereira JSF, Moraes DP, Dressler VL, Flores EMM, Knapp G (2009) Nickel, vanadium and sulfur determination by inductively coupled plasma optical emission spectrometry in crude oil distillation residues after microwave-induced combustion. J Anal Atom Spectrom 24:911–916

    Article  CAS  Google Scholar 

  33. Pereira JSF, Mello PA, Duarte FA, Santos MFP, Guimarães RCL, Knapp G, Dressler VL, Flores EMM (2009) Feasibility of microwave-induced combustion for digestion of crude oil vacuum distillation residue for chlorine determination. Energy Fuels 23:6015−6019

    Google Scholar 

  34. Moraes DP, Mesko MF, Mello PA, Paniz JNG, Dressler VL, Knapp G, Flores EMM (2007) Application of microwave-induced combustion in closed vessels for carbon black-containing elastomers decomposition. Spectrochim Acta Part B 62:1065–1071

    Article  CAS  Google Scholar 

  35. Pozebon D, Dressler VL, Curtius AJ (1998) Study of interferences from Na and Cl using ETV-ICP-MS. Atom Spectrosc 19:80–88

    CAS  Google Scholar 

  36. Allain P, Jaunault L, Mauras Y, Mermet J-M, Delaporte T (1991) Signal enhancement of elements due to the presence of carbon-containing compounds in inductively coupled plasma mass spectrometry. Anal Chem 63:1497–1498

    Article  CAS  Google Scholar 

Download references

Acknowledgments

The authors are grateful for fellowships provided by CAPES, CNPq ,and Fapergs and to Metrohm AG (Switzerland and partner in Brazil) for IC support. The authors also thank Dr. Marco Aurélio Zezi Arruda (UNICAMP) for lending the infrared thermometer.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Érico M. M. Flores.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Moraes, D.P., Pereira, J.S.F., Diehl, L.O. et al. Evaluation of sample preparation methods for elastomer digestion for further halogens determination. Anal Bioanal Chem 397, 563–570 (2010). https://doi.org/10.1007/s00216-010-3478-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00216-010-3478-1

Keywords

Navigation