Abstract
This paper reports our experience with endovascular techniques for the retrieval of lost or misplaced intravascular objects. Over 12 years, 78 patients were referred for interventional retrieval of intravascular foreign objects. In this retrospective study, radiological procedure records and patients’ medical records were reviewed to determine the exact removal procedure in every case, to report success rates, and to identify significant procedure-related complications. Written, informed consent was obtained from all patients prior to the intervention; this retrospective analysis was performed according to the guidelines of the Institutional Review Board. Thirty-six of seventy-eight foreign objects (46%) were located in the venous system, 27 of 78 (35%) in the right heart, and 15 of 78 (19%) in the pulmonary arteries. For foreign object removal, in 71 of 78 (91%) cases a snare loop was used, in 6 of 78 (8%) cases a sidewinder catheter combined with a snare loop was used, and in 1 case (1%) a sidewinder catheter alone was used for foreign object removal. In 68 of 78 (87%) cases, primary success was achieved. In 3 of 78 cases (4%), foreign objects were successfully mobilized to the femoral vessels and surgically removed. In 7 of 78 cases (9%), complete removal of the foreign object was not possible. In 5 of 78 cases (6%), minor complications occurred during the removal procedure. In conclusion, endovascular retrieval of lost or misplaced intravascular objects is highly effective, with relatively few minor complications. On the basis of our findings, these techniques should be considered as the therapy of choice.
Similar content being viewed by others
References
Tager IE, Ginsberg MB, Ellis SE, et al. (1983) An epidemiologic study of the risks associated with peripheral intravenous catheters. Am J Epidemiol 118:839–851
Raad I (1998) Intravascular catheter-related infections. Lancet 351:893–898
Goldberger Z, Lampert R (2006) Implantable cardioverter-defibrillators: expanding indications and technologies. JAMA 295:809–818
Cabell CH, Heidenreich PA, Chu VH, et al. (2004) Increasing rates of cardiac device infections among Medicare beneficiaries: 1990–1999. Am Heart J 47:582–586
Thomas J, Sinclair-Smith B, Bloomfield D, et al. (1964) Non-surgical retrieval of a broken segment of steel spring guide from the right atrium and inferior vena cava. Circulation 30:106–108
Dotter CT, Rosch J, Bilbao MK (1971) Transluminal extraction of catheter and guide fragments from the heart and great vessels; 29 collected cases. Am J Roentgenol Radium Ther Nucl Med 111:467–472
Yedlicka JF, Carlson JE, Hunter DW, et al. (1991) Nitinol gooseneck snare for removal of foreign bodies: experimental study and clinical evaluation. Radiology 178:691–693
Leoni CJ, Potter JE, Rosen MP, et al. (2001) Classifying complications of interventional procedures: a survey of practicing radiologists. J Vasc Interv Radiol 12:55–59
Fisher RG, Ferreyro R (1978) Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies. Am J Roentgenol 130:541–548
Richardson JD, Grover FL, Trinkle JK (1974) Intravenous catheter emboli. Experience with twenty cases and collective review. Am J Surg 128:722–727
Bernhardt LC, Wegner GP, Mendenhall JT (1970) Intravenous catheter embolization to the pulmonary artery. Chest 57:329–332
Doering RB, Stemmer EA, Connolly JE (1967) Complications of indwelling venous catheters, with particular reference to catheter embolus. Am J Surg 114:259–266
Druskin MS, Siegel PD (1963) Bacterial contamination of indwelling intravenous polyethylene catheters. JAMA 185:966–968
Donelli G (2006) Vascular catheter-related infection and sepsis. Surg Infect (Larchmt) 7:s25–s27
Wolf F, Thurnher S, Lammer J (2001) Simon nitinol vena cava filters: effectiveness and complications. Rofo 173:924–930
Curry JL (1969) Recovery of detached intravascular catheter or guide wire fragments. A proposed method. Am J Roentgenol Radium Ther Nucl Med 105:894–896
Wahi PL, Talwar KK, Sapru RP (1980) Non-surgical extraction of a broken catheter sheath lodged in the right atrium, using a Dormia ureteral stone dislodger. Br Heart J 44:349–351
Weigele JB, Sheline ME, Cope C (1992) Expandable intravascular catheter: percutaneous use for endoluminal retrievals. Radiology 185:604–606
Bashour TT, Banks T, Cheng TO (1974) Retrieval of lost catheters by a myocardial biopsy catheter device. Chest 66:395–396
Kurita A, Kanazawa M, Kanie T, et al. (1972) Successful removal of a foreign object from the caval vein by use of endo-myocardial bioptome. Jpn Heart J 13:464–469
Shaw TR (1982) Removal of embolised catheters using flexible endoscopy forceps. Br Heart J 48:497–500
Ferry P, Hancock R, Newton C, et al. (2002) Perspectives of relatives and health care workers on care of terminally ill patients in the UK. Am J Hosp Palliat Care 19:121–118
Vujic I, Moore L, McWey RE (1986) Retrieval of coil after unintentional embolization of ileocolic artery. Radiology 160:563–564
Chuang VP, Wallace S, Gianturco C, et al. (1981) Complications of coil embolization: prevention and management Am J Roentgenol 137:809–813
Uflacker R, Lima S, Melichar AC (1986) Intravascular foreign bodies: percutaneous retrieval. Radiology 160:731–735
Gerlock AJ Jr, Mirfakhraee M (1987) Retrieval of intravascular foreign bodies. J Thorac Imaging 2:52–60
Cekirge S, Weiss JP, Foster RG, et al. (1993) Percutaneous retrieval of foreign bodies: experience with the nitinol Goose Neck snare. J Vasc Interv Radiol 4:805–810
Schellhammer F, Zahringer M, Lackner K (2002) Nitinol micro-forceps for retrieval of intravascular objects: first in vitro experiences. Invest Radiol 37:577–579
Cekirge S, Weiss JP, Foster RG, et al. (1993) Percutaneous retrieval of foreign bodies: experience with the nitinol Goose Neck snare. J Vasc Interv Radiol 4:805–810
Egglin TK, Dickey KW, Rosenblatt M, et al. (1995) Retrieval of intravascular foreign bodies: experience in 32 cases. Am J Roentgenol. 164:1259–1264
Cioppa A, Ambrosini V, Battaglia S, et al. (2005) Endovascular foreign body retrieval from right side of the heart: a case series of six patients. Int J Cardiol 99:143–144
Liu JC, Tseng HS, Chen CY, et al. (2004) Percutaneous retrieval of 20 centrally dislodged Port-A catheter fragments. Clin Imaging 28:223–229
Koseoglu K, Parildar M, Oran I, et al. (2004) Retrieval of intravascular foreign bodies with goose neck snare. Eur J Radiol 49:281–285
Gabelmann A, Kramer S, Gorich J (2001) Percutaneous retrieval of lost or misplaced intravascular objects. Am J Roentgenol 176:1509–1513
Sheth R, Someshwar V, Warawdekar G (2007) Percutaneous retrieval of misplaced intravascular foreign objects with the Dormia basket: an effective solution. CardioVasc Interv Radiol 30:48–53
Konya A (2006) Comparison of two foreign body retrieval devices with adjustable loops in a swine model. CardioVasc Interv Radiol 29:1060–1067
Konya A, Choi BG (2006) Comparison of the Texan foreign body retrieval device and the Amplatz goose neck snare in vivo and in vitro. J Vasc Interv Radiol 17:693–702
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Wolf, F., Schernthaner, R.E., Dirisamer, A. et al. Endovascular Management of Lost or Misplaced Intravascular Objects: Experiences of 12 Years. Cardiovasc Intervent Radiol 31, 563–568 (2008). https://doi.org/10.1007/s00270-007-9201-8
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00270-007-9201-8