Skip to main content
Log in

Which Iodine concentration in chest CT? – A prospective study in 300 patients

  • Contrast Media
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract

In computed tomography(CT) several contrast media with different iodine concentrations are available. The aim of this study is to prospectively compare contrast media with iodine concentrations of 300, 370 and 400 mg iodine/ml for chest- CT. 300 consecutive patients were prospectively enrolled, under a waiver of the local ethics committee. The first (second, third) 100 patients, received contrast medium with 300(370, 400)mg iodine/ml. Injection protocols were adapted for an identical iodine delivery rate(1.3 mg/s) and total iodine load(33 g) for all three groups. Standardized MDCT of the chest (16 × 0.75 mm, 120 kVp, 100 mAseff.) was performed. Intravascular attenuation values were measured in the pulmonary trunk and the ascending aorta; subjective image quality was rated on a 3-point-scale. Discomfort during and after injection was evaluated. There were no statistically significant differences in contrast enhancement comparing the three contrast media at the pulmonary trunk(p = 0.3198) and at the ascending aorta(p = 0.0840). Image quality(p = 0.0176) and discomfort during injection(p = 0.7034) were comparable for all groups. General discomfort after injection of contrast media with 300 mg iodine/ml was statistically significant higher compared to 370 mg iodine/ml(p = 0.00019). Given identical iodine delivery rates of 1.3 g/s and iodine loads of 33 g, contrast media with concentrations of 300, 370 and 400 mg iodine/ml do not result in different intravascular enhancement in chest-CT.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Awai K, Hiraishi K, Hori S (2004) Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight. Radiology 230:142–150

    Article  PubMed  Google Scholar 

  2. Heiken JP, Brink JA, McClennan BL, Sagel SS, Forman HP, DiCroce J (1993) Dynamic contrast-enhanced CT of the liver: comparison of contrast medium injection rates and uniphasic and biphasic injection protocols. Radiology 187:327–331

    PubMed  CAS  Google Scholar 

  3. Heiken JP, Brink JA, McClennan BL, Sagel SS, Crowe TM, Gaines MV (1995) Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement. Radiology 195:353–357

    PubMed  CAS  Google Scholar 

  4. Haage P, Schmitz-Rode T, Hubner D, Piroth W, Gunther RW (2000) Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. AJR Am J Roentgenol 174:1049–1053

    PubMed  CAS  Google Scholar 

  5. Bae KT, Heiken JP, Brink JA (2000) Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model. Radiology 207:657–662

    Google Scholar 

  6. Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model. Radiology 207:647–655

    PubMed  CAS  Google Scholar 

  7. Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate–pharmacokinetic analysis and experimental porcine model. Radiology 206:455–464

    PubMed  CAS  Google Scholar 

  8. Brink JA, Heiken JP, Forman HP, Sagel SS, Molina PL, Brown PC (1995) Hepatic spiral CT: reduction of dose of intravenous contrast material. Radiology 197:83–88

    PubMed  CAS  Google Scholar 

  9. Brink JA (2003) Use of high concentration contrast media (HCCM): principles and rationale–body CT. Eur J Radiol 45(Suppl 1):S53–S58

    Article  PubMed  Google Scholar 

  10. Han JK, Kim AY, Lee KY et al (2000) Factors influencing vascular and hepatic enhancement at CT: experimental study on injection protocol using a canine model. J Comput Assist Tomogr 24:400–406

    Article  PubMed  CAS  Google Scholar 

  11. Fleischmann D (2003) Use of high-concentration contrast media in multiple-detector-row CT: principles and rationale. Eur Radiol 13(Suppl 5):M14–M20

    PubMed  Google Scholar 

  12. Fleischmann D (2003) High-concentration contrast media in MDCT angiography: principles and rationale. Eur Radiol 13(Suppl 3):N39–N43

    Article  PubMed  Google Scholar 

  13. Fleischmann D (2003) Use of high concentration contrast media: principles and rationale-vascular district. Eur Radiol 45(Suppl 1):S88–S93

    Google Scholar 

  14. Awai K, Inoue M, Yagyu Y et al (2004) Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor-to-liver contrast at multi-detector row CT. Radiology 233:682–688

    Article  PubMed  Google Scholar 

  15. Awai K, Takada K, Onishi H, Hori S (2002) Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT. Radiology 224:757–763

    Article  PubMed  Google Scholar 

  16. Cademartiri F, de Monye C, Pugliese F et al (2006) High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400. Invest Radiol 41:349–353

    Article  PubMed  Google Scholar 

  17. Furuta A, Ito K, Fujita T, Koike S, Shimizu A, Matsunaga N (2004) Hepatic enhancement in multiphasic contrast-enhanced MDCT: comparison of high- and low-iodine-concentration contrast medium in same patients with chronic liver disease. AJR Am J Roentgenol 183:157–162

    PubMed  Google Scholar 

  18. Sandstede JJ, Werner A, Kaupert C et al (2006) A prospective study comparing different iodine concentrations for triphasic multidetector row CT of the upper abdomen. Eur J Radiol 60:95–99

    Article  PubMed  Google Scholar 

  19. Setty BN, Sahani DV, Ouellette-Piazzo K, Hahn PF, Shepard JA (2006) Comparison of enhancement, image quality, cost, and adverse reactions using 2 different contrast medium concentrations for routine chest CT on 16-slice MDCT. J Comput Assist Tomogr 30:818–822

    Article  PubMed  Google Scholar 

  20. Rist C, Nikolaou K, Kirchin MA et al (2006) Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter. Invest Radiol 41:460–467

    Article  PubMed  Google Scholar 

  21. Sultana S, Morishita S, Awai K et al (2003) Evaluation of hypervascular hepatocellular carcinoma in cirrhotic liver by means of helical CT: comparison of different contrast medium concentrations within the same patient. Radiat Med 21:239–245

    PubMed  Google Scholar 

  22. Tsurusaki M, Sugimoto K, Fujii M, Sugimura K (2004) Multi-detector row helical CT of the liver: quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT–a prospective randomized study. Radiat Med 22:239–245

    PubMed  Google Scholar 

  23. Tsai IC, Lee T, Tsai WL et al (2008) Contrast enhancement in cardiac MDCT: comparison of iodixanol 320 versus iohexol 350. AJR Am J Roentgenol 190:W47–W53

    Article  PubMed  Google Scholar 

  24. Valentine A, Jakobsen JA, Klaveness AJ (1997) Iopentol (Imagopaque 350) compared with diatrizoate (Urografin 370) in cerebral CT. A clinical trial assessing immediate and late (7 days) adverse events and diagnostic information (visualization quality and Hounsfield unit measurements). Eur Radiol 7(Suppl 4):S145–S148

    Article  PubMed  Google Scholar 

  25. Tytle T, Prati RC Jr., Azodo MV, Gutierrez O (1996) A prospective, parallel, double-blind comparison of iodixanol and iohexol in extremity phlebography. Acad Radiol 3(Suppl 3):S519–S523

    Article  PubMed  Google Scholar 

  26. Sundgren PC, Baath L, Tornquist C, Hougens Grynne B, Kjaersgaard P, Almen T (1996) Image quality and safety after iodixanol in intravenous urography; a comparison with iohexol. Br J Radiol 69:699–703

    Article  PubMed  CAS  Google Scholar 

  27. Tveit K, Bolz KD, Bolstad B et al (1994) Iodixanol in cardioangiography. A double-blind parallel comparison between iodixanol 320 mg I/ml and ioxaglate 320 mg I/ml. Acta Radiol 35:614–618

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Georg Mühlenbruch.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mühlenbruch, G., Behrendt, F.F., Eddahabi, M.A. et al. Which Iodine concentration in chest CT? – A prospective study in 300 patients. Eur Radiol 18, 2826–2832 (2008). https://doi.org/10.1007/s00330-008-1080-0

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-008-1080-0

Keywords

Navigation