Skip to main content

Advertisement

Log in

Design and performance evaluation of a novel robotic catheter system for vascular interventional surgery

  • Technical Paper
  • Published:
Microsystem Technologies Aims and scope Submit manuscript

Abstract

Vascular interventional surgery (VIS) is an effective treatment method for vascular diseases. However, there are many problems in traditional VIS, such as surgeons are radiated by X-ray, the lack of well skilled surgeons, the security of the surgery will be reduced due to the Surgeons’ fatigue, high risk of the surgery. To solve these problems, a robotic catheter system is needed to protect the surgeons and enhance the safety of the surgery. In this paper, a novel robotic catheter system with master–slave structure for VIS has been developed. This system is designed with the consideration of the operation method in traditional VIS, which allows the surgeon to operate a real catheter on the master side, then the surgeon make full use of the natural catheter manipulation experience and skills obtained in conventional catheter operation. The salve manipulator operates the catheter insert into the blood vessel with following the operation of the surgeon, and the operating force of the salve manipulator is detected. On the master side, a novel damper-based magnetorheological (MR) fluid is designed to realize the force feedback, which is also used to reappear the operation force from the salve manipulator. The damper connected directly with real catheter is a piston structure using the MR fluid to realize the force feedback. It can transmit the feedback force to surgeon’s hand through the operating catheter connected with damper, which seems that the surgeon operates the catheter beside the patient. The operating transparency of the developed system has been enhanced. The mechanism of the developed system has been introduced in detail. Performance evaluation experiments for the developed robotic catheter system have been done. The experimental results indicated that the developed robotic catheter system is fit for VIS.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19

Similar content being viewed by others

References

  • Antoniou GA, Riga CV, Mayer EK, Cheshire NJW, Bicknell CD (2011) Clinical applications of robotic technology in vascular and endovascular surgery. J Vasc Surg 53(2):493–499

    Article  Google Scholar 

  • Cao T, Wang D, Liu D, Zeng Y (2014) Master–slave remote controlled vascular interventional robot. J Northeast Univ (Nat Sci) 35(4):569–573

    Google Scholar 

  • Feng W, Chi C, Wang H, Wang K, Ye X, Guo S (2006) Highly precise catheter driving mechanism for intravascular neurosurgery. In: Proceedings of IEEE international conference on mechatronics and automation, pp 990–995

  • Fu Y, Gao A, Liu H, Guo S (2011a) The master–slave catheterisation system for positioning the steerable catheter. Int J Mechatron Autom 1:143–152

    Article  Google Scholar 

  • Fu Y, Gao A, Liu H, Li K, Liang Z (2011b) Development of a novel robotic catheter system for endovascular minimally invasive surgery. In: Proceedings of IEEE/ICME international conference on complex medical engineering, pp 400–405

  • Gomes P (2011) Surgical robotics: reviewing the past, analyzing the present, imagining the future. Robot Comput Integr Manuf 27:261–266

    Article  Google Scholar 

  • Guo J, Guo S, Xiao N, Ma X, Yoshida S, Tamiya T, Kawanishi M (2012) A novel robotic catheter system with force and visual feedback for vascular interventional surgery. Int J Mechatron Autom 2(1):15–24

    Article  Google Scholar 

  • Guo J, Guo S, Wang P, Wei W, Wang Y (2013) a novel type of catheter sidewall tactile sensor array for vascular interventional surgery. In: Proceedings of IEEE international conference on complex medical engineering, pp 264–267

  • Kasemi B, Muthalif AGA, Rashid MM, Rahman M (2011) Optimizing dynamic range of magnetorheological fluid dampers: modeling and simulation. In: 4th international conference on mechatronics, pp 1–4

  • Kesner SB, Howe RD (2011) Force control of flexible catheter robots for beating heart surgery. In: 2011 IEEE international conference on robotics and automation, pp 1589–1594

  • Kim KP, Miller DL, Berrington GA, Balter S, Kleinerman RA, Ostroumova E, Simon SL, Linet MS (2012) Occupational radiation doses to operators performing fluoroscopically-guided procedures. Health Phys 103(1):80–99

    Article  Google Scholar 

  • Li S, Shen J, Yan Y, Chen D (2013) Overview of the vascular interventional surgery robot. Chin J Med Instrum 37(2):119–122

    Google Scholar 

  • Liu B, Bai X, Meng C, Lv S, Zhou F (2011) Image-guided navigation system for robot-based vessel intervention surgery based on conventional single plane C-arm. Proc Environ Sci 8:276–283

    Article  Google Scholar 

  • Lu W, Wang D, Liu D, Tian Z, Gao B, Zhang L (2013) Regarding application of robotic telemanipulation system in vascular interventional surgery. J Vasc Surg 57(5):1452–1453

    Article  Google Scholar 

  • Mohapatra A, Greenberg RK, Mastracci TM, Eagleton MJ, Thornsberry B (2013) Radiation exposure to operating room personnel and patients during endovascular procedures. J Vasc Surg 58(3):702–709

    Article  Google Scholar 

  • Park JW, Choi J, Pak HN, Song SJ, Lee JC, Park Y, Shin SM, Sun K (2010) Development of a force-reflecting robotic platform for cardiac catheter navigation. Artif Organs 34(11):1034–1039

    Article  Google Scholar 

  • Payne CJ, Rafii-Tari H, Yang G (2012) A force feedback system for endovascular catheterisation. In: Proceedings of IEEE/RSJ international conference on IROS, pp 1298–1304

  • Simorov A, Otte RS, Kopietz CM, Oleynikov D (2012) Review of surgical robotics user interface: what is the best way to control robotic surgery. Surg Endosc 26:2117–2125

    Article  Google Scholar 

  • Srimathveeravalli G, Kesavadas T, Li X (2010) Design and fabrication of a robotic mechanism for remote steering and positioning of interventional devices. Int J Med Robot Comput Assist Surg 6:160–170

    Google Scholar 

  • Tanimoto M, Arai F, Fukuda T, Itoigawa K, Hashimoto M, Takahashi I, Negoro M (2000) Telesurgery system for intravascular neurosurgery. In: Medical image computing and computer-assisted intervention—MICCAI, pp 29–39

  • Tercero CR, Najdovski Z, Ikeda S, Nahavandi S, Fukuda T (2013) Haptic feedback in endovascular tele-surgery simulation through vasculature phantom morphology changes. In: IEEE world haptics conference, pp 359–364

  • Zakaria NA, Komeda T, Low CY, Makoto M, Kobayashi M, Ismail AY, Dumitrescu R (2013) Development of foolproof catheter guide system based on mechatronic design. Prod Eng Res Dev 7:81–90

    Article  Google Scholar 

  • Zhang P, Yu SC, Hu Y, Ma X, Zhang JW (2011) Design of a novel master–slave robotic system for minimally intravascular invasive surgery. In: Proceedings of IEEE international conference on mechatronics and automation, pp 259–264

  • Zhao H, Duan X (2011) Design of a catheter operating system with active supporting arm for vascular interventional surgery. In: 2011 third international conference on intelligent human–machine systems and cybernetics, pp 169–172

  • Zhao H, Duan X, Huang Q, Wang X, Chen Y, Yu H (2011) Mechanical design and control system of vascular interventional robot. In: Proceedings of IEEE/ICME international conference on complex medical engineering, pp 357–362

Download references

Acknowledgments

This research is supported by National High Technology Research Development Plan (863 Plan: 2015AA040102) and General Research Program of the Natural Science Foundation of Tianjin (13JCYBJC38600) and the Project-sponsored by SRF for ROCS, SEM (2014020).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jian Guo.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Guo, J., Guo, S., Shao, L. et al. Design and performance evaluation of a novel robotic catheter system for vascular interventional surgery. Microsyst Technol 22, 2167–2176 (2016). https://doi.org/10.1007/s00542-015-2659-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00542-015-2659-4

Keywords

Navigation