Abstract

Over the past years, microelectromechanical systems (MEMS) have become a vital component within a wide range of technologies, making the study of their performance and operational reliability a very critical aspect for their correct functionality. Microgrippers are one such type of MEMS devices with one of their key applications being the manipulation of biological tissues and cells. This paper presents a microgripper design based on the ‘hot and cold arm’ electrothermal actuation mechanism that is suitable to study the deformability properties of human red blood cells under healthy and pathological conditions. The main scope of this paper is to highlight a number of failure mechanisms that are typical of surface micromachined MEMS microgrippers. These include out-of-plane buckling of the hot arm, stress concentrations, device stiction, and residual stresses. The studied polysilicon microgripper structures were designed and fabricated in line with the specifications of the commercial fabrication process PolyMUMPsTM. The microgripper design was numerically modelled and electrothermomechanically studied using finite element analysis in CoventorWare\(^{\circledR }\). Experimental testing on the fabricated structures was used to demonstrate reliable microgripper performance as well as instances of the considered failure mechanisms. Results for the reliable microgripper performance show that the microgripper arms deflected as expected when actuated, with the obtained simulation and experimental results in good agreement. The investigated failure mechanisms have led to the identification of essential design and fabrication considerations whose thorough investigation, with the aid of appropriate modelling approaches, is essential to define improvement solutions and best practices to mitigate the failure or malfunction of the microgripper during operation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
Fig. 20
Fig. 21
Fig. 22
Fig. 23
Fig. 24
Fig. 25
Fig. 26
Fig. 27
Fig. 28
Fig. 29

Similar content being viewed by others

References

Download references

Acknowledgements

The technical help of Ryan Bugeja and Mark Anthony Callus from the Institute of Sustainable Energy at the University of Malta in the use of the optical profilometer is acknowledged.

Funding

The research work disclosed in this publication is funded by the Reach High Scholars Programme - Post-Doctoral Grants. The grant is part-financed by the European Union, Operational Programme II - Cohesion Policy 2014–2020 Investing in human capital to create more opportunities and promote the wellbeing of society - European Social Fund (ESF): Grant No. 254/15/05.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Marija Cauchi.

Ethics declarations

Conflicts of interest

The authors declare that they have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Cauchi, M., Grech, I., Mallia, B. et al. Essential design and fabrication considerations for the reliable performance of an electrothermal MEMS microgripper. Microsyst Technol 28, 1435–1450 (2022). https://doi.org/10.1007/s00542-019-04363-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00542-019-04363-w

Navigation