Abstract
Over the past years, microelectromechanical systems (MEMS) have become a vital component within a wide range of technologies, making the study of their performance and operational reliability a very critical aspect for their correct functionality. Microgrippers are one such type of MEMS devices with one of their key applications being the manipulation of biological tissues and cells. This paper presents a microgripper design based on the ‘hot and cold arm’ electrothermal actuation mechanism that is suitable to study the deformability properties of human red blood cells under healthy and pathological conditions. The main scope of this paper is to highlight a number of failure mechanisms that are typical of surface micromachined MEMS microgrippers. These include out-of-plane buckling of the hot arm, stress concentrations, device stiction, and residual stresses. The studied polysilicon microgripper structures were designed and fabricated in line with the specifications of the commercial fabrication process PolyMUMPsTM. The microgripper design was numerically modelled and electrothermomechanically studied using finite element analysis in CoventorWare\(^{\circledR }\). Experimental testing on the fabricated structures was used to demonstrate reliable microgripper performance as well as instances of the considered failure mechanisms. Results for the reliable microgripper performance show that the microgripper arms deflected as expected when actuated, with the obtained simulation and experimental results in good agreement. The investigated failure mechanisms have led to the identification of essential design and fabrication considerations whose thorough investigation, with the aid of appropriate modelling approaches, is essential to define improvement solutions and best practices to mitigate the failure or malfunction of the microgripper during operation.
Similar content being viewed by others
References
Bagolini A, Ronchin S, Bellutti P, Chist M, Verotti M, Belfiore NP (2017) Fabrication of novel MEMS microgrippers by deep reactive ion etching with metal hard mask. J Microelectromech Syst 26(4):926–934. https://doi.org/10.1109/JMEMS.2017.2696033
Cauchi M, Mollicone P, Mallia B, Grech I, Sammut N (2016) Design and analysis of a MEMS-based electrothermal microgripper. In: Proceedings of the international CAE conference 2016, Parma, Italy, pp 1–6
Cauchi M, Grech I, Mallia B, Mollicone P, Sammut N (2018a) Analytical, numerical and experimental study of a horizontal electrothermal MEMS microgripper for the deformability characterisation of human red blood cells. Micromachines 9(3):108. https://doi.org/10.3390/mi9030108
Cauchi M, Grech I, Mallia B, Mollicone P, Sammut N (2018b) The effects of structure thickness, air gap thickness and silicon type on the performance of a horizontal electrothermal MEMS microgripper. Actuators 7(3):38. https://doi.org/10.3390/act7030038
Cauchi M, Mollicone P, Mallia B, Grech I, Portelli B, Sammut N (2018c) Design and fabrication considerations, numerical modelling, and testing of a MEMS microgripper. In: Symposium on design, test, integration packaging of MEMS and MOEMS (DTIP), pp 1–6. https://doi.org/10.1109/DTIP.2018.8394193
Chen K-S (2006) Chapter 9: Techniques in residual stress measurement for MEMS and their applications, volume 4: sensors and actuators. In: MEMS/NEMS handbook techniques and applications. Springer, pp 263–339
Cho SW, Chasiotis I (2007) Elastic properties and representative volume element of polycrystalline silicon for MEMS. Exp Mech 47(1):37–49. https://doi.org/10.1007/s11340-006-0405-7
Chronis N, Lee LP (2005) Electrothermally activated SU-8 microgripper for single cell manipulation in solution. J Microelectromech Syst 14(4):857–863. https://doi.org/10.1109/JMEMS.2005.845445
Coleman NR, Starman LA, Coutu RA (2009) Residual stress of assembling, partially assembling and actuating MEMS devices. In: Proceedings of the SEM annual conference, Albuquerque, New Mexico, USA, pp 1–6
Coutu RA, LaFleur RS, Walton JPK, Starman LA (2016) Thermal management using MEMS bimorph cantilever beams. Exp Mech 56(7):1293–1303. https://doi.org/10.1007/s11340-016-0170-1
Cowen A, Hames G, Monk D, Wilcenski S, Hardy B (2011a) SOIMUMPs design handbook, rev 8.0. Technical report. MEMSCAP Inc., Durham
Cowen A, Hardy B, Mahadevan R, Wilcenski S (2011b) PolyMUMPs design handbook, rev. 13.0. Technical report. MEMSCAP Inc., Durham
DelRio Frank W, Dunn Martin L, de Boer Maarten P (2008) Capillary adhesion model for contacting micromachined surfaces. Scr Mater 59(9):916–920. https://doi.org/10.1016/j.scriptamat.2008.02.037
Di Giamberardino P, Bagolini A, Bellutti P, Rudas IJ, Verotti M, Botta F, Belfiore NP (2017) New MEMS tweezers for the viscoelastic characterization of soft materials at the microscale. Micromachines 9(1):15. https://doi.org/10.3390/mi9010015
Dochshanov A, Verotti M, Belfiore NP (2017) A comprehensive survey on microgrippers design: operational strategy. J Mech Des 139(7):070801. https://doi.org/10.1115/1.4036352
Feng Y-Y, Chen S-J, Hsieh P-H, Chu W-T (2016) Fabrication of an electro-thermal micro-gripper with elliptical cross-sections using silver-nickel composite ink. Sens Actuators A Phys 245:106–112. https://doi.org/10.1016/j.sna.2016.04.045
Hannon B, Ruth M (2009) Malaria and sickle cell anemia. In: Dynamic modeling of diseases and pests. Springer, New York, pp 63–81
Hibbeler RC (1997) Mechanics of materials, 3rd edn. Prentice Hall, Englewood Cliffs
Hickey R, Kujath M, Hubbard T (2002) Heat transfer analysis and optimization of two-beam microelectromechanical thermal actuators. J Vac Sci Technol A 20(3):971–974. https://doi.org/10.1116/1.1468654
Huang Q-A, Lee NKS (1999) Analysis and design of polysilicon thermal flexure actuator. J Micromech Microeng 9(1):64
Iamoni S, Somà A (2014) Design of an electro-thermally actuated cell microgripper. Microsyst Technol 20(4):869–877. https://doi.org/10.1007/s00542-013-2065-8
Ivanova K, Ivanov T, Badar A, Volland BE, Rangelow IW, Andrijasevic D, Sumecz F, Fischer S, Spitzbart M, Brenner W, Kostic I (2006) Thermally driven microgripper as a tool for micro assembly. Microelectron Eng 83(4):1393–1395. https://doi.org/10.1016/j.mee.2006.01.072
Jia Y, Xu Q (2013) MEMS microgripper actuators and sensors: the state-of-the-art survey. Recent Patents Mech Eng 6(2):132–142. https://doi.org/10.2174/2212797611306020005
Kennedy JB, Madugula MKS (1990) Elastic analysis of structures: classical and matrix methods, chapter 7–9. Harper & Row, New York
Kim C-J, Pisano AP, Muller RS (1992) Silicon-processed overhanging microgripper. J Microelectromech Syst 1(1):31–36. https://doi.org/10.1109/84.128053
Kim K, Liu X, Zhang Y, Cheng J, Yu WuX, Sun Y (2008) Elastic and viscoelastic characterization of microcapsules for drug delivery using a force-feedback MEMS microgripper. Biomed Microdevices 11(2):421. https://doi.org/10.1007/s10544-008-9248-6
Lin L, Chiao M (1996) Electrothermal responses of lineshape microstructures. Sens Actuators A Phys 55(1):35–41. https://doi.org/10.1016/S0924-4247(96)01247-2. ISSN 0924-4247. In: International workshop on thermal investigations of ICs and microstructures (THERMINIC workshop). http://www.sciencedirect.com/science/article/pii/S0924424796012472. Accessed 5 Jan 2019
Merlijn Van Spengen W, Puers R, De Wolf I (2003) On the physics of stiction and its impact on the reliability of microstructures. J Adhes Sci Technol 17(4):563–582. https://doi.org/10.1163/15685610360554410
Miller DC, Boyce BL, Dugger MT, Buchheit TE, Gall K (2007) Characteristics of a commercially available silicon-on-insulator MEMS material. Sens Actuators A Phys 138(1):130–144. https://doi.org/10.1016/j.sna.2007.04.023
Nguyen N-T, Ho S-S, Low CL-N (2004) A polymeric microgripper with integrated thermal actuators. J Micromech Microeng 14(7):969
Potrich C, Lunelli L, Bagolini A, Bellutti P, Pederzolli C, Verotti M, Belfiore NP (2018) Innovative silicon microgrippers for biomedical applications: Design, mechanical simulation and evaluation of protein fouling. Actuators 7(2):12. https://doi.org/10.3390/act7020012
Senturia SD (2001) Structures. In: Microsystem design. Kluwer Academic Publishers, Massachusetts, pp 222–235
Tomaiuolo G (2014) Biomechanical properties of red blood cells in health and disease towards microfluidics. Biomicrofluidics 8(5):051501. https://doi.org/10.1063/1.4895755
Verotti M, Dochshanov A, Belfiore NP (2017) A comprehensive survey on microgrippers design: mechanical structure. J Mech Des 139(6):060801. https://doi.org/10.1115/1.4036351
Yang S, Xu Q (2017) A review on actuation and sensing techniques for MEMS-based microgrippers. J Micro-Bio Robot 13(1):1–14. https://doi.org/10.1007/s12213-017-0098-2
Zhang R, Chu J, Wang H, Chen Z (2013) A multipurpose electrothermal microgripper for biological micro-manipulation. Microsyst Technol 19(1):89–97. https://doi.org/10.1007/s00542-012-1567-0
Zhang Y, Chen BK, Liu X, Sun Y (2010) Autonomous robotic pick-and-place of microobjects. IEEE Trans Robot 26(1):200–207. https://doi.org/10.1109/TRO.2009.2034831
Acknowledgements
The technical help of Ryan Bugeja and Mark Anthony Callus from the Institute of Sustainable Energy at the University of Malta in the use of the optical profilometer is acknowledged.
Funding
The research work disclosed in this publication is funded by the Reach High Scholars Programme - Post-Doctoral Grants. The grant is part-financed by the European Union, Operational Programme II - Cohesion Policy 2014–2020 Investing in human capital to create more opportunities and promote the wellbeing of society - European Social Fund (ESF): Grant No. 254/15/05.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflicts of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Cauchi, M., Grech, I., Mallia, B. et al. Essential design and fabrication considerations for the reliable performance of an electrothermal MEMS microgripper. Microsyst Technol 28, 1435–1450 (2022). https://doi.org/10.1007/s00542-019-04363-w
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00542-019-04363-w