Abstract
In this work, an algorithm was developed to record and suppress the physiological tremor present in the hands of surgeon doing robotic surgical procedure due to fatigue or otherwise. A prototype setup of master handle having six degree of freedom with a vibration motor was designed and fabricated to record the hand tremor. The work involved recording the composite simulated motion consisting of both voluntary motion of surgeon’s hand and associated involuntary motion of tremor in real time, determination of peak frequencies of both the motions and providing necessary information on the graphical user interface. The adaptive algorithm is capable to cancel out the involuntary motion from the recorded raw signal in real time. After filtration, only voluntary motion remains for further processing. The developed algorithm promises potential to make robotic surgery more precise and error free.
References
Adhikari K, Tatinati S, Ang WT, Veluvolu KC, Nazarpour KA (2016) Quaternion weighted fourier linear combiner for modeling physiological tremor. IEEE Trans Biomed Eng. https://doi.org/10.1109/TBME.2016.2530564
Atashzar SF, Shahbazi M, Samotus O, Tavakoli M, Mandar SJ, Patel RV (2016) Characterization of upper-limb pathological tremors: application to design of an augmented haptic rehabilitation system. IEEE J Sel Top Signal Process. https://doi.org/10.1109/jstsp.2016.2530632
Bye RT, Neilson PD (2010) The bump model of response planning: intermittent predictive control accounts for 10 Hz physiological tremor. Hum Moment Sci. https://doi.org/10.1016/j.humov.20
Carignan B, Daneault JF, Duval C (2012) The organization of upper limb physiological tremor. Eur J Appl Physiol 112:1269–1284. https://doi.org/10.1007/s00421-011-2080-3
Cheung K, Lee G, Djupsund K, Dan Y, Lee L (2000) A new neural probe using SOI wafers with topological interlocking mechanisms. In: 1st annual international IEEE-EMBS special topic conference on microtechnologies in medicine and biology (Lyon, France), pp 507–511. https://doi.org/10.1109/MMB.2000.893836
Cole BT, Roy SH, Luca CJD, Nawab SH (2014) Dynamical learning and tracking of tremor and dyskinesia from wearable sensors. IEEE Trans Neural Syst Rehabil Eng 22:982–991. https://doi.org/10.1109/TNSRE.2014.2310904
Copur EH, Freeman CT, Chu B, Laila DS (2019) Repetitive control of electrical stimulation for tremor suppression. IEEE Trans Control Syst Technol 27:540–552. https://doi.org/10.1109/TCST.2017.2771327
Deuschl G, Raethjen J, Lindermann M, Krack P (2001) The pathophysiology of tremor. Muscle Nerve 24:716–735. https://doi.org/10.1002/mus.1063
Dorigo DD, Moranz C, Graf H, Marx M, Wendler D, Shui B, Herbawi AS, Kuhl M, Ruther P, Paul O (2018) Fully immersible subcortical neural probes with modular architecture and a delta-sigma ADC integrated under each electrode for parallel readout of 144 recording sites. IEEE J Solid State Circuits 53:3111–3125. https://doi.org/10.1109/JSSC.2018.2873180
Fiath R, Raducanu BC, Musa S, Andrei A, Lopez CM, Hoof CV, Ruther P, Aarts A, Horvath D, Ulbert I (2018) A silicon-based neural probe with densely-packed low-impedance titanium nitride microelectrodes for ultrahigh-resolution in vivo recordings. J Biosens Bioelectron 106:86–92. https://doi.org/10.1016/j.bios.2018.01.060
Herbawi AS, Christ O, Kiessner L, Mottaghi S, Hofmann UG, Paul O, Ruther P (2018) CMOS neural probe with 1600 close-packed recording sites and 32 analog output channels. J Microelectromech Syst 27:1023–1034. https://doi.org/10.1109/jmems.2018.2872619
Herrnstadt G, Menon C (2016) Admittance-based voluntary-driven motion with speed-controlled tremor rejection. IEEE/ASME Trans Mechatron 21:2108–2119. https://doi.org/10.1109/TMECH.2016.2555811
Iseri E, Kuzum D (2017) Implantable optoelectronic probes for in vivo optogenetics. J Neural Eng. https://doi.org/10.1088/1741-2552/aa60b3
Kim GH, Kim K, Lee E, An T, Choi W, Lim G, Shin JH (2018) Recent progress on microelectrodes in neural interfaces. J Mater 11:1–25. https://doi.org/10.3390/ma11101995
Kim C, Jeong J, Kim SJ (2019) Recent progress on non-conventional microfabricated probes for the chronic recording of cortical neural activity. J Sens 19:1–23. https://doi.org/10.3390/s19051069
Latt WT, Veluvolu KC, Ang WT (2011) Drift-free position estimation of periodic or quasi-periodic motion using inertial sensors. Sensors 11:5931–5951. https://doi.org/10.3390/s110605931
Randall JE (1973) A stochastic time series model for hand tremor. J Appl Physiol 34:390–395. https://doi.org/10.1152/jappl.1973.34.3.390
Riviere CN, Ang WT, Khosla PK (2003) Toward active tremor cancelling in handheld microsurgical instruments. IEEE Trans Robot Autom 19:793–800. https://doi.org/10.1109/TRA.2003.817506
Robinson BW, Garduno DH, Saquib M (2010) Fixed and floating-point implementations of linear adaptive techniques for predicting physiological hand tremor in microsurgery. IEEE J Sel Top Signal Process 4:659–667. https://doi.org/10.1109/JSTSP.2010.2048240
Rocon E, Lois BJM, Ruiz AF, Manto M, Moreno JC, Pons JL (2007) Design and validation of a rehabilitation robotic exoskeleton for tremor assessment and suppression. IEEE Trans Neural Syst Rehabil Eng 15:367–378. https://doi.org/10.1109/TNSRE.2007.903917
Roy SS, Barman SS (2018) A non-invasive cancer gene detection technique using FLANN based adaptive filter. Microsyst Technol 24:1–16. https://doi.org/10.1007/s00542-018-4036-6
Shahtalebi S, Atashzar SF, Patel RV, Mohammadi A (2019) HMFP-DBRNN: real-time hand motion filtering and prediction via deep bidirectional RNN. IEEE Robot Autom Lett 4:1061–1068. https://doi.org/10.1109/LRA.2019.2894005
Shieh MY, Wang CY, Wu WL, Liang JM (2018) Gesture recognition based human-robot interactive control for robot soccer. Microsyst Technol 25:1–12. https://doi.org/10.1007/s00542-018-4138-1
Steinmetz NA, Koch C, Harris KD, Carandini M (2018) Challenges and opportunities for large-scale electrophysiology with neuropixels probes. Curr Opin Neurobiol 50:92–100. https://doi.org/10.1016/j.conb.2018.01.009
Su ELM, Win TL, Ang WT, Lim TC, Teo CL, Burdet E (2009) Micromanipulation accuracy in pointing and tracing investigated with a contact-free measurement system. In: Annual international conference of the IEEE engineering in medicine and biology society (EMBS), pp 3960–3963. https://doi.org/10.1109/IEMBS.2009.5333665
Suilleabhain PE, Matsumoto JY (1998) Time-frequency analysis of tremors. Brain 121:2127–2134. https://doi.org/10.1093/brain/121.11.2127
Tatinati S, Veluvolu KC, Hong SM, Latt WT, Ang WT (2013) Physiological tremor estimation with auto-regressive (AR) model and Kalman filter for robotics applications. IEEE Sens J 13:4977–4985. https://doi.org/10.1109/JSEN.2013.2271737
Tatinati S, Nazarpour K, Ang WT, Veluvolu KC (2017) Multidimensional modeling of physiological tremor for active compensation in handheld surgical robotics. IEEE Trans Ind Electron 64:1645–1655. https://doi.org/10.1109/TIE.2016.2597119
Tibdewal MN, There AS, Mahadevappa M, Ray AK, Malokar M (2018) Performance analysis of power and power variance for classification, detection and localization of epileptic multi-channel EEG. Microsyst Technol 24:1–14. https://doi.org/10.1007/s00542-018-3789-2
Veluvolu KC, Ang WT (2010) Estimation and filtering of physiological tremor for real-time compensation in surgical robotics applications. Int J Med Robot Comput Assist Surg 6:334–342. https://doi.org/10.1002/rcs.340
Veluvolu KC, Ang WT (2011) Estimation of physiological tremor from accelerometers for real-time applications. Sensors 11:3020–3036. https://doi.org/10.3390/s110303020
Veluvolu KC, Tatinati S, Hong SM, Ang WT (2013) Multistep prediction of physiological tremor for surgical robotic applications. IEEE Trans Biomed Eng 60:3074–3082. https://doi.org/10.1109/TBME.2013.2264546
Vernooij CA, Lakie M, Reynolds RF (2015) The complete frequency spectrum of physiological tremor can be recreated by broadband mechanical or electrical drive. J Neurophysiol 113:647–656. https://doi.org/10.1152/jn.00519.2014
Wang K, Takemura N, Iwai D, Sato K (2016) A typing assist system considering involuntary hand tremor. Trans Virtual Real Soc Jpn (TVRSJ) 21:227–233. https://doi.org/10.18974/tvrsj.21.2_227
Wang K, Iwai D, Sato K (2017) Supporting trembling hand typing using optical see-through mixed reality. IEEE Access 5:10700–10708. https://doi.org/10.1109/ACCESS.2017.2711058
Wang K, Matsukura H, Iwai D, Sato K (2018a) Stabilizing graphically extended hand for hand tremors. IEEE Access 6:28838–28847. https://doi.org/10.1109/ACCESS.2018.2840101
Wang Y, Tatinati S, Adhikari K, Huang L, Nazarpour K, Veluvolu KC (2018b) Multi-step prediction of physiological tremor with random quaternion neurons for surgical robotics applications. IEEE Access 6:42216–42226. https://doi.org/10.1109/ACCESS.2018.2852323
Zhou Y, Jenkins ME, Naish MD, Trejos AL (2016) Design and validation of a high-order weighted-frequency fourier linear combiner-based Kalman filter for Parkinsonian tremor estimation. In: 38th annual international conference of the IEEE engineering in medicine and biology society (EMBC), Orlando, FL, pp 5893–5896. https://doi.org/10.1109/EMBC.2016.7592069
Zhou Y, Jenkins ME, Naish MD, Trejos AL (2018) Characterization of Parkinsonian hand tremor and validation of a high-order tremor estimator. IEEE Trans Neural Syst Rehabil Eng 26:1823–1834. https://doi.org/10.1109/TNSRE.2018.2859793
Acknowledgements
Authors are thankful to CSIR-Central Scientific Instruments Organization, Chandigarh, India for financial support and providing facilities to conduct the experimental work.
Author information
Authors and Affiliations
Contributions
AK has contributed in experimental work and collected the data. SK and AK worked on design of experiment and carried out the analysis. AK and JSS participated in identifying the characteristics of recorded data and interpretation of results obtained.
Corresponding author
Ethics declarations
Conflict of interest
The authors declare no conflict of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Kumar, A., Kumar, S., Kaushik, A. et al. Real time estimation and suppression of hand tremor for surgical robotic applications. Microsyst Technol 28, 305–311 (2022). https://doi.org/10.1007/s00542-019-04736-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00542-019-04736-1