Halm-Zielke instrumentation for primary stable anterior scoliosis surgery: operative technique and 2-year results in ten consecutive adolescent idiopathic scoliosis patients within a prospective clinical trial

  • Technical innovation
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

Halm-Zielke instrumentation (HZI) was developed to eliminate the disadvantages of Zielke instrumentation (VDS) in terms of lack of primary stability and a kyphogenic effect. HZI is an anterior double-rod system. The system is composed of a lid-plate, which is fixed at the lateral aspect of the vertebral body with two screws, a sunk screw anteriorly and a VDS screw posteriorly. The lid-plate design provides the lowest possible implant profile. The longitudinal components consist of a threaded VDS rod and a solid, fluted rod. Correction is performed with the threaded rod and the solid rod. The solid rod allows internal derotation and relordosation, eliminates the Zielke three-point lever system and augments the system. The fluted design of the rod provides rotatory stability. This is a report of the first ten consecutive adolescent idiopathic scoliosis patients in a prospective clinical trial using HZI with a minimum follow-up of 2 years. Curves ranged from 36° to 77°. Correction of the frontal plane averaged 77.5% and 72.2% postoperatively and at follow-up, respectively. Thoracolumbar kyphosis was present in three patients and corrected in all from an average of + 18° to +1.7° at follow-up. Implant-related complications were not observed. All patients were treated without any additional external immobilization. In our opinion, HZI is a major improvement on the original Zielke VDS. It eliminates the kyphogenic effect and provides primary stability.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 17 November 1997 Revised: 21 March 1998 Accepted: 6 April 1998

Rights and permissions

Reprints and permissions

About this article

Cite this article

Halm, H., Liljenqvist, U., Niemeyer, T. et al. Halm-Zielke instrumentation for primary stable anterior scoliosis surgery: operative technique and 2-year results in ten consecutive adolescent idiopathic scoliosis patients within a prospective clinical trial. E Spine J 7, 429–434 (1998). https://doi.org/10.1007/s005860050103