Skip to main content
Log in

Airborne bacteria, fungi, and endotoxin levels in residential microenvironments: a case study

  • Original Paper
  • Published:
Aerobiologia Aims and scope Submit manuscript

Abstract

Limited data are currently available on the concentrations of airborne bacteria, fungi, and endotoxins in indoor environments. The levels of aerial bacteria and fungi were measured at several microenvironments within a well-ventilated residential apartment in Singapore including the living room, kitchen, bedroom, toilet, and at a workplace environment by sampling indoor air onto culture medium plates using the 6-stage Andersen sampler. Total microbial counts were determined by collecting the air samples in water with the Andersen sampler, staining the resultant extracts with a fluorescent dye, acridine orange, and counting the microbes using a fluorescent microscope. The levels of airborne endotoxins were also determined by sampling the airborne microorganisms onto 0.4 μm polycarbonate membrane filter using the MiniVol sampler at 5 l/min for 20 h with a PM2.5 cut-off device. The aerial bacterial and fungal concentrations were found to be in the ranges of 117–2,873 CFU/m3 and 160–1,897 CFU/m3, respectively. The total microbial levels ranged from 49,000 to 218,000 microbes/m3. The predominant fungi occurring in the apartment were Aspergillus and Penicillium while the predominant bacterial strains appeared to be Staphylococcus and Micrococcus. The average indoor endotoxin level was detectable in the range of 6–39 EU/m3. The amount of ventilation and the types of human activities carried out in the indoor environment appeared to be important factors affecting the level of these airborne biological contaminants.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Abt, E., Suh, H. H., Allen, G., & Koutrakis, P. (2000). Characterisation of indoor particle sources: A study conducted in the metropolitan Boston area. Environmental Health Perspectives, 108, 35–44.

    Article  CAS  Google Scholar 

  • ACGIH. (1989). Guidelines for the assessment of bioaerosols in the indoor environment. In American Conference of Governmental Industrial Hygienists, Cincinnati, OH.

  • Alexopoulos, C. J., & Mims, C. W. (1952). Introductory mycology (3rd ed.). USA: John Wiley & Sons Inc.

    Google Scholar 

  • Andersen, A. A. (1958). New sampler for collection, sizing and enumeration of viable airborne particles. Journal of Bacteriology, 76, 471–484.

    CAS  Google Scholar 

  • ASHRAE Standard-55. (1992). Thermal environment conditions for human occupancy. In American society of heating, refrigerating & air-conditioning engineers, Inc, Atlanta, GA, USA.

  • Awad, A. H. A. (2007). Airborne dust, bacteria, actinomycetes and fungi at a flourmill. Aerobiologia, 23, 59–69.

    Article  Google Scholar 

  • Aydogdu, H., Asan, A., Otkun, M. T., & Ture, M. (2005). Monitoring of fungi and bacteria in the indoor air of primary schools in Edirne city, Turkey. Indoor and Built Environment, 14, 411–425.

    Article  CAS  Google Scholar 

  • Brunekreef, B., de Rijk, L., Verhoeff, A. P., & Samson, R. (1990). Classification of dampness in homes. In Indoor Air’90. Proceedings of the 5th International Conference on Indoor Air Quality and Climate, Toronto (pp. 15–20).

  • Burge, H. A. (1985). Fungus allergens. Clinical Reviews in Allergy, 3, 319–329.

    Article  CAS  Google Scholar 

  • Burge, H. (1990). Bioaerosols: Prevalence and health effects in the indoor environment. Journal of Allergy and Clinical Immunology, 86, 687–701.

    Article  CAS  Google Scholar 

  • Carty, C. L., Gehring, U., Cyrys, J., Bischof, W., & Heinrich, J. (2003). Seasonal variability of endotoxin in ambient fine particulate matter. Journal of Environmental Monitoring, 5, 953–958.

    Article  CAS  Google Scholar 

  • Desai, M. R., & Ghosh, S. K. (2003). Occupational exposure to airborne fungi among ricemill workerswith special reference to aflatoxin producing A-flavus strains. Annals of Agricultural and Environmental Medicine, 10, 159–162.

    Google Scholar 

  • Douwes, J., Versloot, P., Hollander, A., Heederik, D., & Doekes, G. (1995). Influence of various dust sampling and extraction methods on the measurement of airborne endotoxin. Applied and Environmental Microbiology, 61, 1763–1769.

    CAS  Google Scholar 

  • Dowd, S. E., & Maier, R. M. (2000). Aeromicrobiology. In R. M. Maier, I. L. Pepper, & C. P. Gerba (Eds.), Environmetal microbiology (pp. 91–122). San Diego: Academic.

    Google Scholar 

  • Ellis, J. J. (1981). The effect of medium temperature and age on Rhizopus delemar sporangiospore size. Mycologia, 73, 362–368.

    Article  Google Scholar 

  • Gehring, U., Bischof, W., Fahlbusch, B., Wichmann, H. E., & Heinrich, J. (2002). House dust endotoxin and allergic sensitization in children. American Journal of Respiratory and Critical Care Medicine, 166, 939–944.

    Article  Google Scholar 

  • Gehring, U., Bolte, G., Borte, M., Bischof, W., Fahlbusch, B., Wichmann, H. E., et al. (2001). Exposure to endotoxin decreases the risk of atopic eczema in infancy: A cohort study. Journal of Allergy and Clinical Immunology, 108, 847–854.

    Article  CAS  Google Scholar 

  • Gereda, J. E., Klinnert, M. D., Price, R., Leung, Y. M. D., & Liu, H. A. (2001). Metropolitan home living conditions associated with indoor endotoxin levels. Journal of Allergy and Clinical Immunology, 107, 790–796.

    Article  CAS  Google Scholar 

  • Gorny, R. L., Dutkiewicz, J., & Krysiska-Traczyk, E. (1999). Size distribution of bacterial and fungal bioaerosols in indoor air. Annals of Agriculture and Environmental Medicine, 6, 105–113.

    CAS  Google Scholar 

  • Griffiths, W. D., & DeCosemo, G. A. L. (1994). The assessment of bioaerosols: A critical review. Journal of Aerosol Science, 25, 1425–1458.

    Article  CAS  Google Scholar 

  • Guo, H., Lee, S. C., & Chan, L. Y. (2004). Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong Kong. Science of the Total Environmental, 323, 87–98.

    Article  CAS  Google Scholar 

  • Haas, D., Habib, J., Galler, H., Buzina, W., Schlacher, R., Marth, E., et al. (2007). Assessment of indoor air in Austrian apartments with and without visible mold growth. Atmospheric Environment, 41, 5192–5201.

    Article  CAS  Google Scholar 

  • Hameed, A. A. A., Shakour, A. A., & Yasser, H. I. (2003). Evaluation of bio-aerosols at an animal feed manufacturing industry: A case study. Aerobiologia, 19, 1573–3025.

    Google Scholar 

  • Heederik, D., Brouwer, R., Biersteker, K., & Boleij, J. S. M. (1991). Relationship of airborne endotoxin and bacteria levels in pig farms with the lung function and respiratory symptoms of farmers. International Archives of Occupational and Environmental Health, 62, 595–601.

    Article  CAS  Google Scholar 

  • Heinrich, J., Pitz, M., Bischof, W., Krug, N., & Borm, P. J. A. (2003). Endotoxin in fine (PM2.5) and coarse (PM2.5–10) particle mass of ambient aerosols. A temporo-spatial analysis. Atmospheric Environment, 37, 3659–3667.

    Article  CAS  Google Scholar 

  • Hsu, N. Y., Chen, P. Y., Chang, H. W., & Su, H. J. (2011). Changes in profiles of airborne fungi in flooded homes in southern Taiwan after Typhoon Moraket. Science of the Total Environment, 409, 1677–1682.

    Article  CAS  Google Scholar 

  • Hunter, C. A., Grant, C., Flannigan, B., & Bravery, A. F. (1988). Mould in buildings: The air spora of domestic dwellings. International Biodeterioration, 24, 81–101.

    Article  Google Scholar 

  • Hunter, C. A., Hull, A. V., Higham, D. F., Grimes, C. P., & Lea, R. G. (1996). Fungi and bacteria. In R. W. Berry, V. M. Brown, S. K. D. Coward, D. R. Crump, M. Gavin, C. P. Grimes, D. F. Higham, A. V. Hull, C. A. Hunter, R. G. Lea, J. W. Llewellyn, & G. J. Raw (Eds.), Indoor air quality in homes: The building research establishment indoor environment study (pp. 99–117). Wartford: Building Research Establishment.

    Google Scholar 

  • Jothish, P. S., & Nayar, T. S. (2004). Airborne fungal spores in a sawmill environment in Palakkad District, Kerala, India. Aerobiologia, 20, 75–81.

    Article  Google Scholar 

  • Karlsson, K., & Malmberg, P. (1989). Characterisation of exposure to moulds and actinomycetes in agricultural dusts by scanning electron microscopy. Scandinavian Journal of Work and Environmental Health, 5, 353–359.

    Article  Google Scholar 

  • Kim, K. Y., & Kim, C. N. (2007). Airborne microbiological characteristics in public buildings of Korea. Building and Environment, 42, 2188–2196.

    Article  Google Scholar 

  • Kullman, G. J., Thorne, P. S., Waldron, P. F., Marx, J. J., Ault, B., Lewis, D. M., Siegel, P. D., Olenchock S. A., & Merchant, J. A. (1998). Organic dust exposures from work in diary barns. American Industrial Hygiene Association Journal, 59, 403–414.

    Google Scholar 

  • Lacey, J., & Dutkiewicz, J. (1994). Bioaerosols and occupational lung-disease. Journal of Aerosol Science, 25, 1371–1404.

    Article  CAS  Google Scholar 

  • Lee, S. (2010). Prevalence of childhood asthma in Korea: International study of asthma and allergies in childhood. Allergy Asthma Immunol Res, 2, 61–64.

    Google Scholar 

  • Lee, K. Y. A., Chan, C. K., Fang, M., & Lau, P. S. A. (2004). The 3-hydroxy fatty acids as biomarkers for quantification and characterisation of endotoxins and gram-negative bacteria in atmospheric aerosols in Hong Kong. Atmospheric Environment, 38, 6307–6317.

    Article  CAS  Google Scholar 

  • Lee, J. H., & Jo, W. K. (2006). Characteristics of indoor and outdoor bioaerosols at Korean high-rise apartment buildings. Environmental Research, 101, 11–17.

    Article  CAS  Google Scholar 

  • Li, C. S., & Kuo, Y.-M. (1993). Characteristics of indoor viable fungi in Taiwan. In Indoor Air’93. Proceedings of the 6th International Conference on Indoor Air Quality and Climate, Helsinki (pp. 183–187).

  • Liao, V. H., Chio, C. P., Chou, W. C., Ju, Y. R., & Liao, C. M. (2010). Modeling human health risks of airborne endotoxin in homes during the winter and summer seasons. Science of the Total Environment, 408, 1530–1537.

    Article  CAS  Google Scholar 

  • Lim, T. K. (2003). Overview of asthma care in Singapore. The Singapore Family Physician, 29, 7–8.

    Google Scholar 

  • Long, M. C., Suh, H. H., Kobzik, L., Catalano, P. J., Ning, Y. Y., & Koutrakis, P. (2001). A pilot investigation of the relative toxicity of indoor and outdoor fine particles: In vitro effects of endotoxin and other particulate properties. Environmental Health Perspectives, 109, 1019–1026.

    CAS  Google Scholar 

  • Meklin, T., Hyvärinen, A., Toivola, M., Reponen, T., Koponen, V., Husman, T., et al. (2003). Effect of building frame and moisture damage on microbiological indoor air quality in school buildings. American Industrial Hygiene Association Journal, 64, 108–116.

    Article  Google Scholar 

  • Michel, O., Ginanni, R., Duchateau, J., Vertongen, F., Le Bon, B., & Sergysels, R. (1991). Domestic endotoxin exposure and clinical severity of asthma. Clinical and Experimental Allergy, 21, 441–448.

    Article  CAS  Google Scholar 

  • Michel, O., Ginanni, R., & Sergysels, R. (1992). Relation between the bronchial obstractive response to inhaled lipopolysaccharide and bronchial responsiveness to histamine. Thorax, 47, 288–291.

    Article  CAS  Google Scholar 

  • Michel, O., Kips, J., Duchateau, J., Vertongen, F., Robert, L., Collet, H., et al. (1996). Severity of asthma is related to endotoxin in house dust. American Journal of Respiratory Critical Care and Medicine, 154, 1641–1646.

    CAS  Google Scholar 

  • Moschandreas, D. J., Cha, D. K., & Qian, J. (1996). Measurement of indoor bioaerosol levels by direct counting method. Journal of Environmental Engineering, 122, 374–378.

    Article  CAS  Google Scholar 

  • Muilenberg, M. L. (1995). The outdoor aerosols. In H. A. Burge (Ed.), Bioaerosols, indoor air research series (p. 163). Boca Raton, Florida, USA: CRC Press, Inc.

    Google Scholar 

  • Musk, A. W., Venables, K. M., Crook, B., Nunn, A. J., Hawkins, R., & Crook, G. D. W. (1989). Respiratory symptoms, lung-function, and sensitization to flour in a British bakery. British Journal of Industrial medicine, 46, 636–642.

    CAS  Google Scholar 

  • NEA. (1996). Indoor air quality guidelines. In Guidelines for good indoor air quality in office premises (1st ed.). Singapore: National Environmental Agency. http://app2.nea.gov.sg/airquality_guidelines.aspx.

  • Ng, T. P., & Tan, W. C. (1999). Temporal trends and ethnic variations in asthma mortality in Singapore, 1976–1995. Thorax, 54, 990–994.

    Article  CAS  Google Scholar 

  • Nilsson, S., Merritt, A. S., & Bellander, T. (2011). Endotoxins in urban air in Stockholm, Swedan. Atmospheric Environment, 45, 266–270.

    Article  CAS  Google Scholar 

  • NUH. (2002). The NUH Children’s Medical Institute (CMI) launches “I CAN!” programme for children suffering from asthma and allergies in Singapore. http://www.nuh.com.sg/wbn/slot/u1756/bulletins/bulletin_2.8.pdf.

  • NUH. (2003). Asia-Pacific specialists in asthma and allergies to look into increasing number of children suffering from asthma and allergies. http://www.nuh.com.sg/wbn/slot/u1753/Patients%20and%20Visitors/Media%20Releases/2003/24%20Nov%2003.pdf.

  • Oppliger, A., Rusca, S., Charriere, N., Duc, T. V., & Droz, P. O. (2005). Assessment of bioaerosols and inhalable dust exposure in Swiss sawmills. Annals of Occupational Hygiene, 49, 385–391.

    Article  CAS  Google Scholar 

  • Osornio-Vargas, A. R., Bonner, J. C., Alfaro-Moreno, E., Martinez, L., Garcia-Cuellar, C., Rosales, S. P., et al. (2003). Proinflammtory and cytotoxic effects of Mexico city air pollution particulate matter in vitro are dependent on particle size and composition. Environmental Health Perspectives, 111, 1289–1294.

    Article  CAS  Google Scholar 

  • Owen, M. K., Ensor, D. S., & Sparks, L. (1992). Airborne particle sizes and sources found in indoor air. Atmospheric Environmental Part A-General Topics, 26, 2149–2162.

    Article  Google Scholar 

  • Palmgren, U., Ström, G., Blomquist, G., & Malmberg, P. (1986). Collection of airborne microorganisms on nucleopore filters, estimation and analysis-CAMNEA method. Journal of Applied Bacteriology, 61, 401–406.

    Article  CAS  Google Scholar 

  • Park, J. H., Spiegelman, D. L., Burge, H., Gold, D. R., Chew, G. L., & Milton, D. K. (2000). Longitudinal study of dust and airborne endotoxin in the home. Environmental Health Perspectives, 109, 859–864.

    Article  Google Scholar 

  • Park, J. H., Spiegelman, D. L., Gold, D. R., Burge, H. A., & Milton, D. K. (2001). Predictors of airborne endotoxin in the home. Environmental Health and Perspectives, 109, 859–864.

    Article  CAS  Google Scholar 

  • Park, C. W., Yoon, K. Y., Kim, Y. D., Park, J. H., & Hwang, J. (2011). Effects of condensational growth on culturability of airborne bacteria: Implications for sampling and control of bioaerosols. Journal of Aerosol Science, 42, 213–223.

    Article  CAS  Google Scholar 

  • Pasanen, A. L. (1992). Airborne mesophilic fungal spores in various residential environments. Atmospheric Environmental Part A-General Topics, 26, 2861–2868.

    Article  Google Scholar 

  • Pasanen, A. L., Kasanen, J. P., Rautiala, S., Ikaheimo, M., Rantamaki, J., & Kaariainen, H. (2000). Fungal growth and survival in building materials under fluctuating moisture and temperature conditions. International Biodeterioration and Biodegadation, 46, 117–127.

    Article  Google Scholar 

  • Platts-Mills, T. A. E., Custis, N. J., Woodfolk, J. A., & Platts-Mills, T. A. E. (2005). Airborne endotoxin in homes with domestic animals: Implications for cat-specific tolerance. Journal of Allergy and Clinical Immunology, 116, 384–389.

    Article  CAS  Google Scholar 

  • Rennie, D. C., Lawson, J. A., Kirychuk, S. P., Paterson, C., Willson, P. J., Senthilselvan, A., et al. (2008). Assessment of endotoxin levels in the home and current asthma and wheeze in school-age children. Indoor Air, 18, 447–453.

    Article  CAS  Google Scholar 

  • Reponen, T., Hyvarinen, A., Ruuskanen, J., Raunemaa, T., & Nevalainen, A. (1994). Comparison of concentrations and size distributions of fungal spores in buildings with and without mold problems. Journal Aerosol Science, 25, 1595–1603.

    Article  CAS  Google Scholar 

  • Reponen, T., Hyvärinen, A., Ruuskanen, J., Raunemaa, T., & Nevlalainen, A. (1993). Size distribution of fungal spores in houses with mould problems. In Indoor Air’93. Proceedings of the 6th International Conference on Indoor Air Quality and Climate, Helsinki (pp. 183–187).

  • Reponen, T., Willeke, K., Ginshpun, S., & Nevlalainen, A. (2001). Biological particle sampling. In P. A. Baron & K. Willeke (Eds.), Aerosol measurement. Hoboken, New Jersey, USA: John Wiley & sons Inc.

    Google Scholar 

  • Reynolds, S. J., Thorne, P. S., Donham, K. J., Croteau, E. A., et al. (2002). Comparison of endotoxin assays using agricultural dusts. American Industrial Hygiene Assoc Journal, 63, 430–438.

    Article  CAS  Google Scholar 

  • Rolka, H., Krajewska-Kulak, E., Lukaszuk, C., Oksiejczuk, E., Jakoniuk, P., Leszczynska, K., et al. (2005). Indoor air studies of fungi contamination of social welfare home in Czerewki in north-east part of Poland. Roczniki Akademii Medycznej w Bialymstoku, 50(Suppl 1), 26–30.

    Google Scholar 

  • Rosas, I., Calderon, C., Salinas, E., Martınez, L., Alfaro-Moreno, E., & Milton, D. K. (2001). Animal and worker exposure to dust and biological particles in animal care houses. Aerobiologia, 17, 49–59.

    Article  Google Scholar 

  • Rylander, R. (2002). Endotoxin in the environment—exposure and effects. Journal of Endotoxin Research, 8, 241–252.

    CAS  Google Scholar 

  • Rylander, R., Bake, B., Fischer, J. J., & Helander, I. M. (1989). Pulmonary function and symptoms after inhalation of endotoxin. American Review of Respiratory Disease, 140, 981–986.

    CAS  Google Scholar 

  • Savino, E., & Caretta, G. (1992). Airborne fungi in an Italian rice mill. Aerobiologia, 8, 267–275.

    Article  Google Scholar 

  • Schram-Bijkerk, D., Doekes, G., Douwes, J., Boeve, M., Riedler, J., Üblagger, E., et al. (2005). Bacterial and fungal agents in house dust and wheez in children: The PARSIFAL study. Clinical and Experimental Allergy, 35, 1272–1278.

    Article  CAS  Google Scholar 

  • Shelton, B. G., Kirkland, K. H., Flanders, W. D., & Morris, G. K. (2002). Profiles of airborne fungi in buildings and outdoor environments in the United States. Applied and Environmental Microbiology, 68, 1743–1753.

    Article  CAS  Google Scholar 

  • Singh, A., & Singh, A. B. (1994). Airborne fungi in a bakery and the prevalence of respiratory dysfunction among workers. Grana, 33, 349–358.

    Article  Google Scholar 

  • Sly, R. M. (1988). Mortality from asthma, 1979–1984. Journal of Allergy and Clinical Immunology, 82, 705–717.

    Article  CAS  Google Scholar 

  • Sneath, P. H. A., Mair, N. S., Sharpe, M. E., & Holt, J. G. (1986). Bergey’s manual of systematic bacteriology. Baltimore: Williams & Wilkins Inc.

    Google Scholar 

  • So, S. Y., Ng, M. M. T., & Ip, M. M. S. (1990). Rising asthma mortality in Hong Kong, 1976–85. Respiratory Medicine, 84, 457–467.

    Article  CAS  Google Scholar 

  • Su, H. J., Wu, P. C., Chen, H. L., Lee, F. C., & Lin, L. L. (2001). Exposure assessment of indoor allergens, endotoxin, and airborne fungi for homes in southern Taiwan. Environmental Research, 85, 135–144.

    Article  CAS  Google Scholar 

  • Sykes, P., Morris, R. H. K., Allen, J. A., Wildsmith, J. D., & Jones, K. P. (2011). Workers’ exposure to dust, endotoxin and β-(1–3) glucan at four large-scale composting facilities. Waste Management, 31, 423–430.

    Article  CAS  Google Scholar 

  • Thorne, P. S., Cohn, R. D., Mav, D., Arbes, S. J., & Zeldin, D. C. (2009). Predictors of endotoxin levels in U.S. housing. Environmental Health Perspectives, 117, 763–771.

    CAS  Google Scholar 

  • Thorne, P. S., & DeKoster, J. A. (1996). Environmental assessment of aerosols, bioaerosols and airborne endotoxins in a machining plant. American Industrial Hygiene Association Journal, 57, 1163–1167.

    Article  CAS  Google Scholar 

  • Thorne, P. S., Reynolds, S. J., Milton, D. K., & Bloebaum, P. D. (1997). Field evaluation of endotoxin air sampling assay methods. American Industrial Hygiene Association Journal, 58, 792–799.

    Article  CAS  Google Scholar 

  • Zorman, T., & Jersek, B. (2008). Assessment of bioaerosol concentrations in different indoor environments. Indoor Built Environment, 17, 155–163.

    Article  Google Scholar 

  • Zucker, B. A., & Muller, W. (2004). Airborne endotoxins and airborne grame-negative bacteria in a residential neighborhood. Water, Air, and Soil pollution, 158, 67–75.

    Article  CAS  Google Scholar 

  • Zuraimi, M. S., & Tham, K. W. (2008). Indoor air quality and its determinants in tropical child care centers. Atmospheric Environment, 42, 2225–2239.

    Article  CAS  Google Scholar 

Download references

Acknowledgments

The authors thank Ms. Ong Yong Mei for her kind assistance with the collection and analysis of air samples during the field studies.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Balasubramanian.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Balasubramanian, R., Nainar, P. & Rajasekar, A. Airborne bacteria, fungi, and endotoxin levels in residential microenvironments: a case study. Aerobiologia 28, 375–390 (2012). https://doi.org/10.1007/s10453-011-9242-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10453-011-9242-y

Keywords

Navigation