Abstract
There is increasing interest in the use of permanently installed monitoring systems to track the progress of corrosion. There is a choice between point thickness measurement systems, those that monitor the average thickness over a modest area, and large area monitoring systems that will detect relatively severe, localised corrosion. The relative merits of the different types of monitoring system are assessed for cases with different likely fractions of the total surface area affected by corrosion. If the wall loss is expected to be fairly uniform over the component surface then a small number of point sensors is the most attractive solution, whereas if the loss is likely to be highly localised at an unpredictable location and potentially severe, a large area monitoring system is most suitable. In the intermediate case of modest loss over a significant fraction of the surface, the choice is more complex. If the requirement is to detect relatively large wall loss that may be localised then the number of point sensors required increases substantially and the average thickness area monitoring systems appear to be more attractive. However, it is shown that corrosion distributions are frequently exponential, and this can lead to large maximum pit depths when the average wall loss is at the margin of detectability with current commercially available systems.
Similar content being viewed by others
References
Cavassi, P., Cornago, M.: The cost of corrosion in the oil and gas industry. In: JPCL, May 1999, pp. 30–40 (1999)
Thomas, M.J.J., Terpstra, S.: Corrosion monitoring in oil and gas production. In: Proc. Corrosion 2003, San Diego, CA, NACE International (2003). Paper 03431
Non-intrusive inspection: Recommended practice document DNV-RP-G103 (2011)
Alleyne, D.N., Pavlakovic, B., Lowe, M.J.S., Cawley, P.: Rapid long-range inspection of chemical plant pipework using guided waves. Insight 43, 93–96 (2001)
Terpstra, S.: Use of statistical techniques for sampling inspection in the oil and gas industry. In: 4th European-American Workshop on Reliability of NDE, Berlin (2009). Paper We.2.A.1
Bridgeman, J., Shankar, R.: Erosion/corrosion data handling for reliable NDE. Nucl. Eng. Des. 131, 285–297 (1991)
Hobbs, C.: Obtaining a clearer picture of corrosion using non-destructive testing. Anti-Corros. Methods Mater. 44(4), 232–235 (1997)
Cegla, F.B., Cawley, P., Allin, J., Davies, J.: High-temperature (>500 ∘C) wall thickness monitoring using dry-coupled ultrasonic waveguide transducers. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 58, 156–167 (2011)
Cegla, F., Allin, J.: Wireless ultrasonic thickness monitoring at elevated temperatures. Mater. Eval. 69(5), A26–A31 (2011)
Bulmer, M.G.: Principles of Statistics. Dover, New York (1979)
Wold, K., Sirnes, G.: FSM technology—16 years of field history—experience, status and further developments. In: NACE International Corrosion Conference, Nashville, TN (2007)
Sposito, G., Cawley, P., Nagy, P.: Potential drop mapping for the monitoring of corrosion or erosion. NDT E Int. 43, 394–402 (2010)
Geir, I., Toppe, M.A., Nagy, P.B.: Acoustic method and system of measuring material loss from a solid structure, uses thereof and a software product. Patent W0 2007/139389 A1 (2007)
Instanes, G.G., Toppe, M., Lakshminarayan, B., Nagy, P.B.: Corrosion and erosion monitoring of pipes by an ultrasonic guided wave method. In: Advanced Ultrasonic Methods for Material and Structure Inspection, pp. 115–157. Hermes Science, London (2006). ISBN 9781905209699
Volker, A., Vos, H.: Experimental results of guided wave travel time tomography. In: Proc. 18th World Conference on Non Destructive Testing, 16–20 April 2012, Durban, South Africa (2012). Available http://www.ndt.net/article/wcndt2012/papers/128_wcndtfinal00128.pdf
Volker, A., Bloom, J.: Guided wave travel time tomography for bends. In: Thompson, D.O., Chimenti, D.E. (eds.) Review of Progress in Quantitative NDE, vol. 30, pp. 223–230. American Institute of Physics, New York (2011)
Huthwaite, P., Ribichini, R., Simonetti, F., Cawley, P., Lowe, M.J.S.: High resolution guided wave tomography. In: Thompson, D.O., Chimenti, D.E. (eds.) Review of Progress in Quantitative NDE, vol. 32. American Institute of Physics, New York (2013, in press)
Stone, M.: Wall thickness distributions for steels in corrosive environments and determination of suitable statistical analysis methods. In: 4th European-American Workshop on Reliability of NDE, Berlin (2009). Paper We.2.A.5
Galvagni, A., Cawley, P.: Guided wave permanently installed pipeline monitoring system. In: Thompson, D.O., Chimenti, D.E. (eds.) Review of Progress in Quantitative NDE, vol. 31, pp. 1591–1598. American Institute of Physics, New York (2012)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Cawley, P., Cegla, F. & Stone, M. Corrosion Monitoring Strategies—Choice Between Area and Point Measurements. J Nondestruct Eval 32, 156–163 (2013). https://doi.org/10.1007/s10921-012-0168-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10921-012-0168-2