Abstract

High energy medical linear accelerators (>10 MV) are increasingly used in radiotherapy. At such high photon energies neutron production via photonuclear reactions in the heavy elements which compose the linac head is inevitable. Neutrons from linacs can contribute to an additional dose to staff, patients and the general public. Our intention is two-fold; to provide shielding against the neutron contamination and to establish the depthdose curve of thermal neutrons within human tissue, with an aim to utilise linacs in boron neuron capture therapy (BNCT). In our studies neutron measurements were undertaken, with a Varian Clinac 2100C/D linear accelerator operating at 15 MV nominal energy, by irradiating 18 cm thick 30×30 cm2 block of tissue equivalent material. Measurements were taken using indium and aluminum activation foil at the centre of the block. Our results show that by leaving the linac jaws open neutron production is increased compared to the case when these are shut, for one minute exposure at 400MU. In this work we present a comparison between our results and existing literature and attempt to explore some sharp contrasts.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. NCRP, Neutron Contamination from Medical Electron Accelerators, NCRP Report 79, 1984.

  2. J. S. Laughlin, A. Reid, L. Zeitz, J. Ding, Proc. Conf. on Neutrons from Electron Medical Accelerators, H. T. Heaton II and R. Jacobs (Eds), NBS Special Publication 554, 1979, p. 1.

  3. R. C. Mccall, W. P. Swanson, Neutron sources and their characteristics, Proc. Conf. on Neutrons from Electron Medical Accelerators, H. T. Heaton II and R. Jacobs (Eds), NBS Special Publication 554, 1979, p. 75.

  4. R. C. Mccall, SALC Report SALC-PUB 4480, Stanford, California, 1987.

  5. F. Bush, Br. J. Radiol., 14 (1946) 1914.

    Google Scholar 

  6. H. M. Garnica-Garza, Phys. Med. Biol., 50 (2005) 531.

    Article  CAS  Google Scholar 

  7. H. S. Kim, Y. H. Park, B. C. Koo, J. W. Kwon, J.-S. Lee, H. S. Choi, Radiat. Prot. Dosim., 123 (2007) 323.

    Article  CAS  Google Scholar 

  8. X. S. Mao, K. R. Kase, J. C. Liu, W. R. Nelson, J. H. Kleck, S. Johnsen, Health Phys., 72 (1997) 524.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. Alfuraih.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Alfuraih, A., Chin, M.P.W. & Spyrou, N.M. Measurements of the photonuclear neutron yield of 15 MV medical linear accelerator. J Radioanal Nucl Chem 278, 681–684 (2008). https://doi.org/10.1007/s10967-008-1504-y

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-008-1504-y

Keywords

Navigation