Contrastive analysis of cooling performance between a high-level water collecting cooling tower and a typical cooling tower

  • Published:
Journal of Thermal Science Aims and scope Submit manuscript

Abstract

A three-dimensional (3D) numerical model is established and validated for cooling performance optimization between a high-level water collecting natural draft wet cooling tower (HNDWCT) and a usual natural draft wet cooling tower (UNDWCT) under the actual operation condition at Wanzhou power plant, Chongqing, China. User defined functions (UDFs) of source terms are composed and loaded into the spray, fill and rain zones. Considering the conditions of impact on three kinds of corrugated fills (Double-oblique wave, Two-way wave and S wave) and four kinds of fill height (1.25 m, 1.5 m, 1.75 m and 2 m), numerical simulation of cooling performance are analysed. The results demonstrate that the S wave has the highest cooling efficiency in three fills for both towers, indicating that fill characteristics are crucial to cooling performance. Moreover, the cooling performance of the HNDWCT is far superior to that of the UNDWCT with fill height increases of 1.75 m and above, because the air mass flow rate in the fill zone of the HNDWCT improves more than that in the UNDWCT, as a result of the rain zone resistance declining sharply for the HNDWCT. In addition, the mass and heat transfer capacity of the HNDWCT is better in the tower centre zone than in the outer zone near the tower wall under a uniform fill layout. This behaviour is inverted for the UNDWCT, perhaps because the high-level collection devices play the role of flow guiding in the inner zone. Therefore, when non-uniform fill layout optimization is applied to the HNDWCT, the inner zone increases in height from 1.75 m to 2 m, the outer zone reduces in height from 1.75 m to 1.5 m, and the outlet water temperature declines approximately 0.4 K compared to that of the uniform layout.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Williamson N., Behnia M., Armfield S. Comparison of a 2D axisymmetric CFD Model of a Natural Draft Wet cooling Tower and a 1D Model. International Journal of Heat and Mass Transfer, 2008, 51(9): 2227–2236.

    Article  Google Scholar 

  2. Jin X., Xie H., Ni J., and Wang Z., The Study on Design of High Level Water Collecting Natural Draft Wet Cooling Tower. Electric Power, 1993, 26(6): 39–43.

    Google Scholar 

  3. Yang H., Yang R., The Summary on Energy-saving and Noise Reduction Cooling Tower. Electric Power Survey & Design, 2015, (s1): 300–303.

    Google Scholar 

  4. Li Z., Zhang G., and Wang Z., The Study on Energy Saving Technology of High-level Cooling Tower in Jiujiang Power Plant. Power Generation Technology, 2017, (2): 49–51.

    Google Scholar 

  5. Bustamante J., Rattner A., and Garimella S., Achieving Near-water-cooled Power Plant Performance with Aircooled Condensers. Applied Thermal Engineering, 2016, 105(25): 362–371.

    Article  Google Scholar 

  6. Kroger D., Air-cooled Heat Exchangers and Cooling Towers: Thermal-flow Performance Evaluation and Design. Stellenbosch University, Stellenbosch, South Africa. 2000.

    Google Scholar 

  7. Kloppers J., and Kroger D., A Critical Investigation into the Heat and Mass Transfer Analysis of Counterflow Wet-cooling Towers. International Journal of Heat and Mass Transfer, 2005, 48(3): 765–777.

    Article  MATH  Google Scholar 

  8. Poppe M., and Rogener H., Berechnug von Ruck Kuhlwerken. VDI-Warmeatlas, 1991(1): 1–15.

    Google Scholar 

  9. Sadasivam M., Balakrishnan A., On the Effective Driving Force for Transport in Cooling Towers. Journal of Heat Transfer, 1995, 117(2): 512–515.

    Article  Google Scholar 

  10. Kloppers J., and Kroger D., Loss Coefficient Correlation for Wet Cooling Tower Fills. Applied Thermal Engineering, 2003, 23(17): 2201–2211.

    Article  Google Scholar 

  11. Gharagheizi F., Hayati R., and Fatemi S, Experimental study on the performance of mechanical cooling tower with two types of film packing. Energy Conversion Management, 2007, 48(1): 277–280.

    Article  Google Scholar 

  12. Williamson N, Armfield S, Behnia M. Numerical Simulation of Flow in a Natural Draft Wet Cooling Tower-the Effect of Radial Thermo fluid Fields, Applied Thermal Engineering, 2008, 28(2): 178–189.

    Article  Google Scholar 

  13. Gao M., Zhang L., Influence of Non-uniform Layout Fillings on Thermal Performance for Wet Cooling Tower. Applied Thermal Engineering, 2016, 93: 549–555.

    Article  Google Scholar 

  14. Liu D., Sun F., Impact Mechanism of Different Fill Layout Patterns on the Cooling Performance of the Wet Cooling Tower with Water Collecting Devices. Applied Thermal Engineering, 2017, 110: 1389–1400.

    Article  Google Scholar 

  15. Patankar S., Numerical Heat Transfer and Fluid Flow. Hemisphere Publishing Corp., Washington, USA, 1980.

    MATH  Google Scholar 

  16. FLUENT: User’s Guide, Fluent Inc., Canonsburg, USA, 2003.

  17. Ferziger J., Peric M., and Leonard A., Computational Methods for Fluid Dynamics. Springer-Verlag, Berlin Heidelberg New York, USA, 1996.

    Google Scholar 

  18. Williamson N., Numerical Modelling of Heat and Mass Transfer and Optimization of a Natural Draft Wet Cooling Tower. The University of Sydney, Sydney, Australia, 2008.

    Google Scholar 

  19. Al-Waked R., and Behnia M., Enhancing Performance of Wet Cooling Towers. Energy Convers Management, 2007, 48(10): 2638–2648.

    Article  Google Scholar 

  20. Radosavljevic., and Dejan, the Numerical Simulation of Direct-contact Natural-draught Cooling Tower Performance under the Influence of Crosswind. American Journal of Cardiology, 1990, 47(2): 449-456.

  21. Fournier Y., Boyer V., Improvements to the N3S-AERO Heat Exchanger and Cooling Tower Simulation Code. 12th IARH Symposium in Cooling Tower and Heat Exchangers, Sydney, Australia, 2001, (11): 11–14.

    Google Scholar 

  22. Majumdar A., Singhal A., and Spalding D., Numerical Modeling of Wet Cooling Towers Part 1: Mathematical and Physical Models. Journal of Heat Transfer, 1983, (105): 728–735.

    Article  Google Scholar 

  23. Test methods for determining the performance of cooling tower of transfer packing. Standards of Power Industry of the People's Republic of China, Beijing, China, 2005.

  24. Zhao S., The Principle of cooling towers. China Construction Industry Publishing, Beijing, China, 2015.

    Google Scholar 

  25. Liu D., and Sun F., Impact Mechanism of Different Fill Layout Patterns on the Cooling Performance of the Wet Cooling Tower with Water Collecting Devices. Applied Thermal Engineering, 2017, 110: 1389–1400.

    Article  Google Scholar 

  26. He S., Guan Z., Gurgenci H., Hooman K., Lu Y., and Alkhedhair A., Experimental Study on the Applications of Two Trickle Media for the inlet Air Pre-cooling of Natural Draft Dry Cooling Towers. Energy Conversion, 2014, (89): 644–654.

    Article  Google Scholar 

  27. Dzivama A., Bindir U., and Aboaba F., Evaluation of pad materials in construction of active evaporative cooler for storage of fruits and vegetables in arid environments. Agricultural Mechanization in Asia Africa and Latin America, 1999, 30(3): 51–55.

    Google Scholar 

  28. Liao C., Chiu K., Wind Tunnel Modelling the System Performance of Alternative Evaporative Cooling Pads in Taiwan Region. Building and Environment, 2002, 37: 177–187.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jin Wang.

Additional information

This study is financially supported by the National Major Projects of China (Grant No. 2014ZX07406002-2)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wang, M., Wang, J., Wang, J. et al. Contrastive analysis of cooling performance between a high-level water collecting cooling tower and a typical cooling tower. J. Therm. Sci. 27, 39–47 (2018). https://doi.org/10.1007/s11630-018-0982-7

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11630-018-0982-7

Keywords

Navigation