Skip to main content
Log in

Numerical simulation of the seismic behavior of self-centering steel beam-column connections with bottom flange friction devices

  • Published:
Earthquake Engineering and Engineering Vibration Aims and scope Submit manuscript

Abstract

A new type of steel moment resisting frame with bottom flange friction devices (BFFDs) has been developed to provide self-centering capacity and energy dissipation, and to reduce permanent deformations under earthquakes. This paper presents a numerical simulation of self-centering beam-column connections with BFFDs, in which the gap opening /closing at the beam-column interfaces is simulated by using pairs of zero-length elements with compression-only material properties, and the energy dissipation due to friction is simulated by using truss elements with specified hysteretic behavior. In particular, the effect of the friction bolt bearing against the slotted plate in the BFFDs was modeled, so that the increase in lateral force and the loss of friction force due to the bolt bearing could be taken into account. Parallel elastic-perfectly plastic gap (ElasticPPGap) materials in the Open System for Earthquake Engineering Simulation (OpenSees) were used with predefined gaps to specify the sequence that each bolt went into the bearing and the corresponding increase in bending stiffness. The MinMax material in OpenSees is used to specify the minimum and maximum values of strains of the ElasticPPGap materials. To consider the loss of friction force due to bolt bearing, a number of parallel hysteretic materials were used, and the failure of these materials in sequence simulated the gradual loss of friction force. Analysis results obtained by using the proposed numerical model are discussed and compared with the test results under cyclic loadings and the seismic loading, respectively.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Chou CC and Chen JH (2010a), “Column Restraint in Post-tensioned Self-centering Moment Frames,” Earthquake Engineering and Structural Dynamics, 39(7), 751–774.

    Google Scholar 

  • Chou CC and Chen JH (2010b), “Tests and Analyses of a Full-scale Post-tensioned RCS Frame Subassembly,” Journal of Constructional Steel Research, 66(11): 1354–1365.

    Article  Google Scholar 

  • Chou CC, Chen JH, Chen YC and Tsai KC (2006), “Evaluating Performance of Posttensioned Steel Connections with Strands and Reduced Flange Plates,” Earthquake Engineering and Structural Dynamics, 35(9): 1167–1185.

    Article  Google Scholar 

  • Chou CC and Lai YJ (2009), “Post-tensioned Selfcentering Moment Connections with Beam Bottom Flange Energy Dissipators,” Journal of Constructional Steel Research, 65(10–11): 1931–1941.

    Article  Google Scholar 

  • Chou CC, Weng CY and Chen JH (2008), “Seismic Design and Behavior of Post-tensioned Connections Including Effects of a Composite Slab,” Engineering Structures, 30(11): 3014–3023.

    Article  Google Scholar 

  • Christopoulos C, Filiatrault A, Uang CM and Folz B (2002), “Posttensioned Energy Dissipating Connections for Moment-resisting Steel Frames,” Journal of Structural Engineering, 128(9): 1111–1120.

    Article  Google Scholar 

  • Garlock MM (2002), “Design, Analysis, and Experimental Behavior of Seismic Resistant Posttensioned Steel Moment Resisting Frames,” Ph.D. Dissertaion, Dept. of Civil Engineering, Lehigh Univ., Bethlehem, Pennsylvania.

    Google Scholar 

  • Garlock M M and Li J (2008), “Steel Self-centering Moment Frames with Collector Beam Floor Diaphragms,” Journal of Constructional Steel Research, 64(5): 526–538.

    Article  Google Scholar 

  • Iyama J, Seo CY, Ricles JM and Sause R (2009), “Selfcentering MRFs with Bottom Flange Friction Devices under Earthquake Loading,” Journal of Constructional Steel Research, 65(2):314–325.

    Article  Google Scholar 

  • Lin YC, Ricles JM and Sause R (2009), “Earthquake Simulations on Self-centering Steel Moment Resisting Frame with Web Friction Devices,” Proceedings of the ASCE Structures Congress, Austin, Texas, April 29–May 2.

  • McKenna F, Fenves GL and Scott MH (2000), “Open System for Earthquake Engineering Simulation,” Berkeley, CA: University of California, Available from: 〈http://OpenSees.berkeley.edu〉.

    Google Scholar 

  • Morgen BG and Kurama YC (2008), “Seismic Response Evaluation of Posttensioned Precast Concrete Frames with Friction Dampers,” Journal of Structural Engineering, 134(1): 132–145.

    Article  Google Scholar 

  • Petty G (1999), “Evaluation of a Friction Component for a Post-tensioned Steel Connection,” M.S. Thesis, Civil and Environmental Engineering Dept., Lehigh Univ., Bethlehem, PA.

    Google Scholar 

  • Ricles JM, Sause R and Garlock MM (2001), “Posttensioned Seismic-resistant Connections for Steel Frames,” Journal of Structural Engineering, 127(2): 113–121.

    Article  Google Scholar 

  • Rojas P (2003), “Seismic Analysis, Design, and Evaluation of Post-tensioned Friction Damped Connections for Steel Moment Resisting Frames,” Ph.D. Dissertation, Civil and Env. Engineering Dept., Lehigh University, Bethlehem, PA.

    Google Scholar 

  • Rojas P, Ricles JM and Sause R (2005), “Seismic Performance of Post-tensioned Steel Moment Resisting Frames with Friction Devices,” Journal of Structural Engineering, 131(4): 529–540.

    Article  Google Scholar 

  • SAC (1995), “Interim Guidelines: Evaluation, Repair, Modification and Design of Welded Steel Moment Frame Structures,” Rep. No. FEMA-267, Federal Emergency Management Agency, Washington, D.C.

    Google Scholar 

  • Tsai KC, Chou CC, Lin CL, Chen PC and Jhang SJ (2008), “Seismic Self-centering Steel Beam-to-column Moment Connections Using Bolted Friction Devices,” Earthquake Engng Struct. Dyn., 37(4): 627–645.

    Article  Google Scholar 

  • Vamvatsikos D and Cornell AC (2002), “Incremental Dynamic Analysis,” Earthquake Engineering and Structural Dynamics, 31(3): 491–514.

    Article  Google Scholar 

  • Wolski M (2006), “Experimental Evaluation of a Bottom Flange Friction Device for a Self Centering Seismic Moment Resistant Frame with Post-tensioned Steel Moment Connections,” M.A.Thesis, Dept. of Civil Engineering, Lehigh Univ., Bethlehem, Pennsylvania.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tong Guo.

Additional information

Supported by: National Natural Science Foundation of China Under Grant No. 51078075

Rights and permissions

Reprints and permissions

About this article

Cite this article

Guo, T., Song, L. & Zhang, G. Numerical simulation of the seismic behavior of self-centering steel beam-column connections with bottom flange friction devices. Earthq. Eng. Eng. Vib. 10, 229–238 (2011). https://doi.org/10.1007/s11803-011-0061-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11803-011-0061-5

Keywords

Navigation