Abstract
In the field of oral rehabilitation, the combined use of 3D imaging technologies and computer-guided approaches allows the development of reliable tools to be used in preoperative assessment of implant placement. In particular, the accurate transfer of the virtual planning into the operative field through surgical guides represents the main challenge of modern dental implantology. Guided implant positioning allows surgical and prosthetic approaches with minimal trauma by reducing treatment time and decreasing patient’s discomfort. This paper aims at defining a CAD/CAM framework for the accurate planning of flapless dental implant surgery. The system embraces three major applications: (1) freeform modelling, including 3D tissue reconstruction and 2D/3D anatomy visualization, (2) computer-aided surgical planning and customised template modelling, (3) additive manufacturing of guided surgery template. The tissue modelling approach is based on the integration of two maxillofacial imaging techniques: tomographic scanning and surface optical scanning. A 3D virtual maxillofacial model is created by matching radiographic data, captured by a CBCT scanner, and surface anatomical data, acquired by a structured light scanner. The pre-surgical planning process is carried out and controlled within the CAD application by referring to the integrated anatomical model. A surgical guide is then created by solid modelling and manufactured by additive techniques. Two different clinical cases have been approached by inserting 11 different implants. CAD-based planned fixture placements have been transferred into the clinical field by customised surgical guides, made of a biocompatible resin and equipped with drilling sleeves.
Similar content being viewed by others
References
Holst, S., Blatz, M.B., Eitner, S.: Precision for computer-guided implant placement: using 3D planning software and fixed intraoral reference points. J. Oral. Maxil. Surg. 65(3), 393–399 (2007). doi:10.1016/j.joms.2006.10.050
Bedi, A., Michalakis, K.X., Mariani, E.J., Zourdos, D.M.: Immediately loaded maxillary and mandibular dental implants with fixed CAD/CAM prostheses using a flapless surgical approach: a clinical report. J. Prosthodont. 20(4), 319–325 (2011). doi:10.1111/j.1532-849X.2011.00689.x
Sclar, A.G.: Guidelines for flapless surgery. J. Oral. Maxil. Surg. 65(7), 20–32 (2007). doi:10.1016/j.joms.2007.03.017
Azari, A., Nikzad, S.: Flapless implant surgery: review of the literature and report of 2 cases with computer-guided surgical approach. J. Oral. Maxil. Surg. 66(5), 1015–1021 (2008). doi:10.1016/j.joms.2007.12.010
Nikzad, S., Azari, A.: Custom-made radiographic template, computed tomography, and computer-assisted flapless surgery for treatment planning in partially edentulous patients: a prospective 12-month study. J. Oral. Maxil. Surg. 68(6), 1353–1359 (2010). doi:10.1016/j.joms.2009.04.108
Rossi, R., Morales, R.S., Frascaria, M., Benzi, R., Squadrito, N.: Planning implants in the esthetic zone using a new implant 3D navigation system. Eur. J. Esthet. Dent. 5(2), 172–188 (2010)
Abboud, M., Orentlicher, G.: An open system approach for surgical guide production. J. Oral. Maxil. Surg. 69(12), E519–E524 (2011). doi:10.1016/j.joms.2011.07.027
Meloni, S.M., De Riu, G., Pisano, M., Cattina, G., Tullio, A.: Implant treatment software planning and guided flapless surgery with immediate provisional prosthesis delivery in the fully edentulous maxilla. A retrospective analysis of 15 consecutively treated patients. Eur. J. Oral. Implantol. 3(3), 245–251 (2010)
Maio, P., de Araujo Nobre, M., Lopes, A., Araujo Nobre, M., Lopes, A.: The use of computer-guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: Preliminary results after a mean follow-up period of thirteen months. J. Prosthet. Dent. 97(6), S26–S34 (2007)
Marchack, C.B.: An immediately loaded CAD/CAM-guided definitive prosthesis: a clinical report. J. Prosthet. Dent. 93(1), 8–12 (2005). doi:10.1016/j.prosdent.2004.10.012
Frascaria, M., Casinelli, M., Marzo, G., Gatto, R., Baldi, M., D’Amario, M.: Digital implant planning for a minimally invasive surgery approach: a case letter of a full-arch rehabilitation. J. Oral Implant. (2013). doi:10.1563/aaid-joi-d-12-00232
Guerrero, M.E., Jacobs, R., Loubele, M., Schutyser, F., Suetens, P., van Steenberghe, D.: State-of-the-art on cone beam CT imaging for preoperative planning of implant placement. Clin. Oral Invest. 10(1), 1–7 (2006). doi:10.1007/s00784-005-0031-2
Van Assche, N., van Steenberghe, D., Quirynen, M., Jacobs, R.: Accuracy assessment of computer-assisted flapless implant placement in partial edentulism. J. Clin. Periodontol. 37(4), 398–403 (2010). doi:10.1111/j.1600-051X.2010.01535.x
Van Assche, N., van Steenberghe, D., Guerrero, M.E., Hirsch, E., Schutyser, F., Quirynen, M., Jacobs, R.: Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. J. Clin. Periodontol. 34(9), 816–821 (2007). doi:10.1111/j.1600-051X.2007.01110.x
Vercruyssen, M., Jacobs, R., Van Assche, N., Van Steenberghe, D.: The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: a critical review on accuracy. J. Oral Rehabil. 35(6), 454–474 (2008). doi:10.1111/j.1365-2842.2007.01816.x
Neugebauer, J., Kistler, F., Kistler, S., Züdorf, G., Freyer, D., Ritter, L., Dreiseidler, T., Kusch, J., Zöller, J.E.: CAD/CAM-produced surgical guides: optimizing the treatment workflow. Int. J. Comput. Dent. 14(2), 93–103 (2011)
D’haese, J., Van De Velde, T., Komiyama, A., Hultin, M., De Bruyn, H.: Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature. Clin. Implant. Dent. R. 14(3), 321–335 (2012). doi:10.1111/j.1708-8208.2010.00275.x
Van Der Zel, J.M.: Implant planning and placement using optical scanning and cone beam CT technology. J. Prosthodont. 17(6), 476–481 (2008)
Bentz, R.M., Balshi, S.F.: Complete oral rehabilitation with implants using CAD/CAM technology, stereolithography, and conoscopic holography. Implant. Dent. 21(1), 8–12 (2012). doi:10.1097/Id.0b013e318243a1aa
Rosenfeld, A.L., Mandelaris, G.A., Tardieu, P.B.: Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 1: Diagnostics, imaging, and collaborative accountability. Int. J. Periodont. Rest. 26(3), 215–221 (2006)
Frisardi, G., Chessa, G., Barone, S., Paoli, A., Razionale, A., Frisardi, F.: Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery. BMC Med Imaging 11 (2011). 10.1186/1471-2342-11-5
De Vos, W., Casselman, J., Swennen, G.R.J.: Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature. Int. J. Oral Max. Surg. 38(6), 609–625 (2009). doi:10.1016/j.ijom.2009.02.028
Miracle, A.C., Mukherji, S.K.: Conebeam CT of the head and neck, part 1: physical principles. Am. J. Neuroradiol. 30(6), 1088–1095 (2009). doi:10.3174/Ajnr.A1653
Miracle, A.C., Mukherji, S.K.: Conebeam CT of the head and neck, part 2: clinical applications. Am. J. Neuroradiol. 30(7), 1285–1292 (2009). doi:10.3174/Ajnr.A1654
Giordano, M., Ausiello, P., Martorelli, M.: Accuracy evaluation of surgical guides in implant dentistry by non-contact reverse engineering techniques. Dent. Mater. 28(9), E178–E185 (2012). doi:10.1016/j.dental.2012.06.006
Barone, S., Paoli, A., Razionale, A.V.: Computer-aided modelling of three-dimensional maxillofacial tissues through multi-modal imaging. Proc. Inst. Mech. Eng. Part H. J. Eng. Med. 227(2), 89–104 (2013). doi:10.1177/0954411912463869
exocad GmbH. www.exocad.com. Accessed 4 March 2014
Barone, S., Paoli, A., Razionale, A.: Creation of 3D multi-body orthodontic models by using independent imaging sensors. Sensors 13(2), 2033–2050 (2013)
Sethi, A., Sochor, P.: Predicting esthetics in implant dentistry using multiplanar angulation: a technical note, vol. 10. vol. 4
Tarnow, D.P., Eskow, R.N.: Preservation of implant esthetics: soft tissue and restorative considerations. J. Esthet. Restor. Dent. 8(6), 12–19 (1996). doi:10.1111/j.1708-8240.1996.tb00904.x
Rodriguez-Ciurana, X., Vela-Nebot, X., Segala-Torres, M., Calvo-Guirado, J.L., Cambra, J., Mendez-Blanco, V., Tarnow, D.P.: The effect of interimplant distance on the height of the interimplant bone crest when using platform-switched implants. Int. J. Periodont. Rest. 29(2), 141–151 (2009)
Teughels, W., Merheb, J., Quirynen, M.: Critical horizontal dimensions of interproximal and buccal bone around implants for optimal aesthetic outcomes: a systematic review. Clin. Oral. Implan. Res. 20, 134–145 (2009). doi:10.1111/j.1600-0501.2009.01782.x
Traini, T., Novaes, A.B., Piattelli, A., Papalexiou, V., Muglia, V.A.: The relationship between interimplant distances and vascularization of the interimplant bone. Clin. Oral Implan. Res. 21(8), 822–829 (2010). doi:10.1111/j.1600-0501.2010.01926.x
Kourkouta, S., Dedi, K.D., Paquette, D.W., Mol, A.: Interproximal tissue dimensions in relation to adjacent implants in the anterior maxilla: clinical observations and patient aesthetic evaluation. Clin. Oral Implan. Res. 20(12), 1375–1385 (2009). doi:10.1111/j.1600-0501.2009.01761.x
Conflict of interest
The authors declare no competing interests.
Informed consent Written informed consent was obtained from the patients for publication of the presented case reports and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Barone, S., Casinelli, M., Frascaria, M. et al. Interactive design of dental implant placements through CAD-CAM technologies: from 3D imaging to additive manufacturing. Int J Interact Des Manuf 10, 105–117 (2016). https://doi.org/10.1007/s12008-014-0229-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12008-014-0229-0