Skip to main content

Advertisement

Log in

An Investigation into the Consistency in Mammographic Density Identification by Radiologists: Effect of Radiologist Expertise and Mammographic Appearance

  • Published:
Journal of Digital Imaging Aims and scope Submit manuscript

Abstract

The aim of this work is to investigate how radiologist expertise and image appearance may have an impact on inter-reader variability of mammographic density (MD) identification. Seventeen radiologists, divided into three expertise groups, were asked to manually segment the areas they consider to be MD in 40 clinical images. The variation in identification of MD for each image was quantified by finding the range of segmentation areas. The impact of radiologist expertise and image appearance on this variation was explored. The range of areas chosen by participating radiologists varied from 7 to 73 % across the 40 images, with a mean range of 35 ± 13 %. Participants with high expertise were more likely to choose similar areas to one another, compared to participants with medium and low expertise levels (mean range were 19 ± 10 %, 29 ± 13 % and 25 ± 14 %, respectively, p < 0.0001). There was a significantly higher average grey level for the area segmented by all radiologists as MD compared to the area of variation, with mean grey level value for 8-bit images being 146 ± 19 vs. 99 ± 14, respectively. MD segmentation borders were consistent in areas where there was a sharp intensity change within a short distance. In conclusion, radiologists with high expertise tend to have a higher agreement when identifying MD. Tissues which have a lower contrast and a less visually sharp gradient change at the interface between high density tissue and adipose background lead to inter-reader variation in choosing mammographic density.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

Abbreviations

MD:

Mammographic density

ROI:

Regions of interest

A%:

Percentage area

R :

Range of segmentation areas

A M :

Median segmentation area

A Comm :

Common segmentation area

A Comb :

Combined segmentation area

A Var :

Variation area

AGL:

Average grey level

D x :

Distance of perpendicular lines

D L :

The longest distance of perpendicular line

D S :

The shortest distance of perpendicular line

References

  1. Wolfe JN: Breast patterns as an index of risk for developing breast cancer. American Journal of Roentgenology. 126:1130–1137, 1976

    Article  CAS  PubMed  Google Scholar 

  2. McCormack VA, Dos Santos SI: Breast density and parenchymal patterns as markers of breast cancer risk: a meta-analysis. Cancer Epidemiology, Biomarkers & Prevention 15:1159–1169, 2006

    Article  Google Scholar 

  3. Huo CW, et al: Mammographic density—a review on the current understanding of its association with breast cancer. Breast Cancer Research and Treatment 144:479–502, 2014

    Article  CAS  PubMed  Google Scholar 

  4. Sickles E, D’Orsi CJ, Bassett LW, et al: ACR BI-RADS® Mammography. In: ACR BI-RADS® Atlas, Breast Imaging Reporting and Data System, Reston, VA, 2013

    Google Scholar 

  5. AL Mousa D, Ryan EA, Mello-Thoms C, Brennan PC: What effect does mammographic breast density have on lesion detection in digital mammography? Clinical Radiology 69:333–341, 2014

    Article  Google Scholar 

  6. Ho JM, Jafferjee N, Covarrubias GM, Ghesani M, Handler B: Dense breasts: a review of reporting legislation and available supplemental screening options. American Journal of Roentgenology 203:449–456, 2014

    Article  PubMed  Google Scholar 

  7. Scheel JR, Lee JM, Sprague BL, Lee CI, Lehman CD: Screening ultrasound as an adjunct to mammography in women with mammographically dense breasts. American Journal of Obstetrics & Gynecology 212(1):9–17, 2014

    Article  Google Scholar 

  8. NINETEEN State Density Laws: is your state one of them? Available at http://www.areyoudense.org/worxcms_published/news_page227.shtml. Accessed November 12 2014.

  9. ACR Statement on Reporting Breast Density in Mammography Reports and Patient Summaries. Available at http://www.acr.org/About-Us/Media-Center/Position-Statements/Position-Statements-Folder/Statement-on-Reporting-Breast-Density-in-Mammography-Reports-and-Patient-Summaries. Accessed 24th April 2012.

  10. ACR Offers Resources to Physicians on Breast Density Notification. Available at http://www.acr.org/Advocacy/eNews/20131004-Issue/ACR-Offers-Resources-to-Physicians-on-Breast-Density-Notification. Accessed November 12 2014.

  11. The State of California: Breast Density Notification Law: Senate Bill No. 1538, 2013

    Google Scholar 

  12. Salvatore M, et al: Breast density: comparison of chest CT with mammography. Radiology 270:67–73, 2014

    Article  PubMed  Google Scholar 

  13. Redondo A, et al: Inter- and intraradiologist variability in the BI-RADS assessment and breast density categories for screening mammograms. British Journal of Radiology 85:1465–1470, 2012

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  14. Ciatto S, et al: A first evaluation of breast radiological density assessment by QUANTRA software as compared to visual classification. Breast 21:503–506, 2012

    Article  PubMed  Google Scholar 

  15. Tagliafico A, et al: Mammographic density estimation: comparison among BI-RADS categories, a semi-automated software and a fully automated one. The Breast 18:35–40, 2009

    Article  PubMed  Google Scholar 

  16. Ooms EA, et al: Mammography: interobserver variability in breast density assessment. Breast 16:568–576, 2007

    Article  CAS  PubMed  Google Scholar 

  17. Martin KE, et al: Mammographic density measured with quantitative computer-aided method: comparison with radiologists’ estimates and BI-RADS categories. Radiology 240:656–665, 2006

    Article  PubMed  Google Scholar 

  18. Nicholson BT, LoRusso AP, Smolkin M, Bovbjerg VE, Petroni GR, Harvey JA: Accuracy of assigned BI-RADS breast density category definitions. Academic Radiology 13:1143–1149, 2006

    Article  PubMed  Google Scholar 

  19. Ciatto S, et al: Categorizing breast mammographic density: intra- and interobserver reproducibility of BI-RADS density categories. The Breast 14:269–275, 2005

    Article  CAS  PubMed  Google Scholar 

  20. Berg WA, Campassi C, Langenberg P, Sexton MJ: Breast Imaging Reporting and Data System: inter- and intraobserver variability in feature analysis and final assessment. American Journal of Roentgenology. 174:1769–1777, 2000

    Article  CAS  PubMed  Google Scholar 

  21. Yaffe MJ: Mammographic density. Measurement of mammographic density. Breast Cancer Research 10:209, 2008

    Article  PubMed Central  PubMed  Google Scholar 

  22. Jeffreys M, Warren R, Highnam R, Davey Smith G: Breast cancer risk factors and a novel measure of volumetric breast density: cross-sectional study. British Journal of Cancer 98:210–216, 2008

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  23. Heine JJ, et al: A novel automated mammographic density measure and breast cancer risk. Journal of the National Cancer Institute 104:1028–1037, 2012

    Article  PubMed Central  PubMed  Google Scholar 

  24. Boyd N, et al: Mammographic density and breast cancer risk: evaluation of a novel method of measuring breast tissue volumes. Cancer Epidemiology, Biomarkers & Prevention 18:1754–1762, 2009

    Article  Google Scholar 

  25. Lee HN, Sohn YM, Han KH: Comparison of mammographic density estimation by Volpara software with radiologists’ visual assessment: analysis of clinical-radiologic factors affecting discrepancy between them. Acta Radiologica. doi: 10.1177/0284185114554674, 2014.

  26. Reed WM, Lee WB, Cawson JN, Brennan PC: Malignancy detection in digital mammograms: important reader characteristics and required case numbers. Academic Radiology 17:1409–1413, 2010

    Article  PubMed  Google Scholar 

  27. Rawashdeh MA, et al: Markers of good performance in mammography depend on number of annual readings. Radiology 269:61–67, 2013

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yanpeng Li.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Li, Y., Brennan, P.C., Lee, W. et al. An Investigation into the Consistency in Mammographic Density Identification by Radiologists: Effect of Radiologist Expertise and Mammographic Appearance. J Digit Imaging 28, 626–632 (2015). https://doi.org/10.1007/s10278-015-9814-4

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10278-015-9814-4

Keywords

Navigation