Abstract
Interfragmentary movement (IFM) at the fracture site plays an important role in fracture healing, particularly during its early stage, via influencing the mechanical microenvironment of mesenchymal stem cells within the fracture callus. However, the effect of changes in IFM resulting from the changes in the configuration of locking plate fixation on cell differentiation has not yet been fully understood. In this study, mechanical experiments on surrogate tibia specimens, manufactured from specially formulated polyurethane, were conducted to investigate changes in IFM of fractures under various locking plate fixation configurations and loading magnitudes. The effect of the observed IFM on callus cell differentiation was then further studied using computational simulation. We found that during the early stage, cell differentiation in the fracture callus is highly influenced by fracture gap size and IFM, which in turn, is highly sensitive to locking plate fixation configuration. The computational model predicted that a small gap size (e.g. 1 mm) under a relatively flexible configuration of locking plate fixation (larger bone-plate distances and working lengths) could experience excessive strain and fluid flow within the fracture site, resulting in excessive fibrous tissue differentiation and delayed healing. By contrast, a relatively flexible configuration of locking plate fixation was predicted to improve cartilaginous callus formation and bone healing for a relatively larger gap size (e.g. 3 mm). If further confirmed by animal and human studies, the research outcome of this paper may have implications for orthopaedic surgeons in optimising the application of locking plate fixations for fractures in clinical practice.
Similar content being viewed by others
References
Pape H-C, Bottlang M (2011) Flexible fixation with locking plates. J Orthop Trauma 25:S1–S3
Wu J-J, Shyr H, Chao E, Kelly P (1984) Comparison of osteotomy healing under external fixation devices with different stiffness characteristics. J Bone Joint Surg Am 66(8):1258–1264
Goodship AE, Kenwright J (1985) The influence of induced micromovement upon the healing of experimental tibial fractures. J Bone Joint Surg Br 67(4):650–655
Claes L, Augat P, Suger G, Wilke HJ (1997) Influence of size and stability of the osteotomy gap on the success of fracture healing. J Orthop Res 15(4):577–584
LE Claes, Wilke HJ, Augat P, Rubenacker S, Margevicius KJ (1995) Effect of dynamization on gap healing of diaphyseal fractures under external fixation. Clin Biomech (Bristol, Avon) 10(5):227–234
Bottlang M, Feist F (2011) Biomechanics of far cortical locking. J Orthop Trauma 25(Suppl 1):S21
Augat P, Simon U, Liedert A, Claes L (2005) Mechanics and mechano-biology of fracture healing in normal and osteoporotic bone. Osteoporos Int 16(2):S36–S43
Perren S (1979) Physical and biological aspects of fracture healing with special reference to internal fixation. Clin Orthop Relat Res 138:175–196
Claes L (2011) Biomechanical principles and mechanobiologic aspects of flexible and locked plating. J Orthop Trauma 25:S4–S7
Haidukewych GJ, Ricci W (2008) Locked plating in orthopaedic trauma: a clinical update. J Am Acad Orthop Surg 16(6):347–355
Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84(8):1093–1110
Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ (2004) Biomechanics of locked plates and screws. J Orthop Trauma 18(8):488–493
Kubiak EN, Fulkerson E, Strauss E, Egol KA (2006) The evolution of locked plates. J Bone Joint Surg Am 88(Suppl 4):189–200. doi:10.2106/JBJS.F.00703
Strauss EJ, Schwarzkopf R, Kummer F, Egol KA (2008) The current status of locked plating: the good, the bad, and the ugly. J Orthop Trauma 22(7):479–486
Henderson CE, Bottlang M, Marsh JL, Fitzpatrick DC, Madey SM (2008) Does locked plating of periprosthetic supracondylar femur fractures promote bone healing by callus formation? Two cases with opposite outcomes. Iowa Orthop J 28:73
Lujan TJ, Henderson CE, Madey SM, Fitzpatrick DC, Marsh JL, Bottlang M (2010) Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation. J Orthop Trauma 24(3):156–162
Miramini S, Zhang L, Richardson M, Pirpiris M, Mendis P, Oloyede K, Edwards G (2015) Computational simulation of the early stage of bone healing under different locking compression plate configurations. Comput Methods Biomech Biomed Eng 18(8):900–913
Miramini S, Zhang L, Richardson M, Mendis P (2014) Computational simulation of mechanical microenvironment of early stage of bone healing under locking compression plate with dynamic locking screws. Appl Mech Mater 553:281–286
Zhang L, Miramini S, Mendis P, Richardson M, Pirpiris M, Oloyede K (2013) The effects of flexible fixation on early stage bone fracture healing. Int J Aerosp Lightweight Struct 3(2):181–189
Thompson Z, Miclau T, Hu D, Helms JA (2002) A model for intramembranous ossification during fracture healing. J Orthop Res 20(5):1091–1098
Klein P, Schell H, Streitparth F, Heller M, Kassi JP, Kandziora F, Bragulla H, Haas NP, Duda GN (2003) The initial phase of fracture healing is specifically sensitive to mechanical conditions. J Orthop Res 21(4):662–669
Le A, Miclau T, Hu D, Helms J (2001) Molecular aspects of healing in stabilized and non-stabilized fractures. J Orthop Res 19(1):78–84
Epari, Taylor WR, Heller MO, Duda GN (2006) Mechanical conditions in the initial phase of bone healing. Clin Biomech (Bristol, Avon) 21(6):646–655. doi:10.1016/j.clinbiomech.2006.01.003
Kenwright J, Goodship AE (1989) Controlled mechanical stimulation in the treatment of tibial fractures. Clin Orthop Relat Res 241:36–47
Goodship AE, Cunningham JL, Kenwright J (1998) Strain rate and timing of stimulation in mechanical modulation of fracture healing. Clin Orthop Relat Res 355:S105–S115
Augat P, Margevicius K, Simon J, Wolf S, Suger G, Claes L (1998) Local tissue properties in bone healing: influence of size and stability of the osteotomy gap. J Orthop Res 16(4):475–481
Gautier E, Sommer C (2003) Guidelines for the clinical application of the LCP. Injury 34:63–76
Duda GN, Mandruzzato F, Heller M, Kassi JP, Khodadadyan C, Haas NP (2002) Mechanical conditions in the internal stabilization of proximal tibial defects. Clin Biomech (Bristol, Avon) 17(1):64–72
Bottlang M, Doornink J, Fitzpatrick DC, Madey SM (2009) Far Cortical Locking Can Reduce Stiffness of Locked Plating Constructs While Retaining Construct Strength. J Bone Joint Surg Am 91a(8):1985–1994. doi:10.2106/Jbjs.H.01038
Döbele S, Horn C, Eichhorn S, Buchholtz A, Lenich A, Burgkart R, Nüssler AK, Lucke M, Andermatt D, Koch R (2010) The dynamic locking screw (DLS) can increase interfragmentary motion on the near cortex of locked plating constructs by reducing the axial stiffness. Langenbeck’s Arch Surg 395(4):421–428
Amano R, Sundén B (2011) Computational fluid dynamics and heat transfer: emerging topics, vol 23. WIT Press, Billerica
Fazi G, Tellini S, Vangi D, Branchi R (2010) Three-dimensional finite element analysis of different implant configurations for a mandibular fixed prosthesis. Int J Oral Maxillofac Implant 26(4):752–759
Cepeda J, Birla S, Subbiah J, Thippareddi HA (2013) Practical method to model complex three-dimensional geometries with non-uniform material properties using image-based design and COMSOL Multiphysics®. In: COMSOL conference, Boston
Mimics (2011). vol 14.11. Materialise, Haasrode, Belgium
Horn C, Doebele S, Vester H, Schaeffler A, Lucke M, Stoeckle U (2011) Combination of interfragmentary screws and locking plates in distal meta-diaphyseal fractures of the tibia: a retrospective, single-centre pilot study. Injury 42(10):1031–1037
Biot MA (2004) General theory of three-dimensional consolidation. J Appl Phys 12(2):155–164
Terzaghi K (1943) Theoretical soil mechanics. Wiley, New York
Oloyede A, Broom N (1991) Is classical consolidation theory applicable to articular cartilage deformation? Clin Biomech 6(4):206–212
Mow V, Kuei S, Lai W, Armstrong C (1980) Biphasic creep and stress relaxation of articular cartilage in compression: theory and experiments. J Biomech Eng 102(1):73–84
Zhang L, Miramini S, Gardiner BS, Smith DW, Grodzinsky AJ (2015) Time evolution of deformation in a human cartilage under cyclic loading. Ann Biomed Eng 43(5):1166–1177
Lacroix D, Prendergast P (2002) A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading. J Biomech 35(9):1163–1171
Prendergast P, Huiskes R, Søballe K (1997) Biophysical stimuli on cells during tissue differentiation at implant interfaces. J Biomech 30(6):539–548
Huiskes R, Van Driel W, Prendergast P, Søballe K (1997) A biomechanical regulatory model for periprosthetic fibrous-tissue differentiation. J Mater Sci Mater Med 8(12):785–788
Isaksson H, van Donkelaar CC, Huiskes R, Ito K (2006) Corroboration of mechanoregulatory algorithms for tissue differentiation during fracture healing: comparison with in vivo results. J Orthop Res 24(5):898–907
Claes L, Reusch M, Göckelmann M, Ohnmacht M, Wehner T, Amling M, Beil FT, Ignatius A (2011) Metaphyseal fracture healing follows similar biomechanical rules as diaphyseal healing. J Orthop Res 29(3):425–432
Woo S, Lothringer K, Akeson W, Coutts R, Woo Y, Simon B, Gomez M (1983) Less rigid internal fixation plates: historical perspectives and new concepts. J Orthop Res 1(4):431–449
McKibbin B (1978) The biology of fracture healing in long bones. J Bone Joint Surg Br 60-B(2):150–162
Perren SM (2008) Fracture healing. The evolution of our understanding. Acta Chir Orthop Traumatol Cech 75(4):241
McCartney W, Mac Donald BJ, Hashmi MSJ (2005) Comparative performance of a flexible fixation implant to a rigid implant in static and repetitive incremental loading. J Materials Process Technol 169(3):476–484. doi:10.1016/j.jmatprotec.2005.04.104
Acknowledgments
The authors would like to thank AOTRAUMA Asia Pacific (AOTAP14-02), DePuy Synthes, Victorian Orthopaedic Research Trust (2014–2015), Epworth HealthCare and the University of Melbourne for their support.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Miramini, S., Zhang, L., Richardson, M. et al. The relationship between interfragmentary movement and cell differentiation in early fracture healing under locking plate fixation. Australas Phys Eng Sci Med 39, 123–133 (2016). https://doi.org/10.1007/s13246-015-0407-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13246-015-0407-9