Elsevier

Thin Solid Films

Volume 260, Issue 2, 15 May 1995, Pages 192-199
Thin Solid Films

Surface chemical activation of quartz crystal microbalance gold electrodes — analysis by frequency changes, contact angle measurements and grazing angle FTIR

https://doi.org/10.1016/0040-6090(94)06474-1Get rights and content

Abstract

A hydroxyalkanethiol, HS(CH2)12OH was deposited onto the gold electrodes of quartz crystal microbalances and gold-coated quartz microscope slides in order to aid in subsequent immobilization of antibodies. FTIR and contact angle measurements confirm the presence of thiol on the fresh gold substrates. In contrast, the change in frequency of the quartz crystal during thiol adsorption indicates an apparent decrease in mass rather than the expected increase due to thiol coverage of the surface. This anomalous behavior appears to be partly due to the removal of organic contaminants from the “aged” gold surface by solvent action. In addition, there may be some dissolution of gold by the thiol solution. QCM frequency changes and FTIR have also been used to monitor subsequent carbodiimide activation of the thiol, as well as antibody binding to the activated surface. The thiolated gold surface was used to fabricate an ordered layer of IgG molecules for probing various immuno-reactions. This was demonstrated by the binding of anti-IgG to IgG in the ratio of ca. 1:1.

References (29)

  • J. Ngeh-Ngwainbi et al.

    Biosensors Bioelectronics

    (1990)
  • K.L. Brillhart et al.

    J. Immunological Methods

    (1991)
  • H. Muramatsu et al.

    Anal. Chim. Acta

    (1986)
  • M. Marquart et al.

    Immunology Today

    (1982)
  • M. Jackson et al.

    J. Mol. Structure

    (1989)
  • A.A. Suleiman et al.

    Anal. Lett.

    (1991)
  • J.E. Hermann

    Methods Emzymol.

    (1981)
  • E. Prusak-Sochaczewski et al.

    Anal. Lett.

    (1990)
  • M. Thompson et al.

    Anal. Chem.

    (1986)
  • C.D. Bain et al.

    J. Am. Chem. Soc.

    (1989)
  • C.D. Bain et al.

    Science

    (1988)
  • S. Lofas et al.

    J. Chem. Soc. Chem. Commun.

    (1990)
  • P.W. Walton et al.

    Biochem. Soc. Trans.

    (1991)
  • G.Z. Sauerbrey

    Z. Phys.

    (1959)
  • Cited by (57)

    • Quartz crystal microbalance with thermally-controlled surface adhesion for an efficient fine dust collection and sensing

      2022, Journal of Hazardous Materials
      Citation Excerpt :

      A quartz crystal microbalance (QCM) is one of the most widely used piezoelectric resonators. It is used in the fields of semiconductor microfabrication, biological events detection, and chemical sensing (Ibano et al., 2010; Geddes et al., 1995; Poller et al., 2017; Slavin, 2018; Gillissen et al., 2017a, 2017b). The resonant frequency of QCM linearly decreases with the mass of deposited materials, defined as the Sauerbrey equation (Sauerbrey, 1959).

    • Phosphorous-filled nanobrick wall multilayer thin film eliminates polyurethane melt dripping and reduces heat release associated with fire

      2013, Polymer Degradation and Stability
      Citation Excerpt :

      QCM crystals were cleaned for 5 min in an enriched plasma environment with a Harrick Plasma treater (Ithaca, NY). Silicon wafers were cleaned for 30 min using bath sonication in a piranha solution [53], and subsequently rinsed in deionized water, acetone and water, and dried with filtered air prior to use. Caution!

    • Sensitive electrochemical sensor for detection of lipopolysaccharide on metal complex immobilized gold electrode

      2012, Sensors and Actuators, B: Chemical
      Citation Excerpt :

      The gold electrode was immersed in 20 mM MPA in ethanol/water (3:1, v/v) overnight. After rinsing with water, the Au/MPA electrode was immersed 10 mM EDC/NHS in MES solution (pH = 6.0) for 10 min, and rinsed with distilled water [22]. The Au/MPA electrode was immersed 5 mM NTA in MES solution (pH = 6.8) for 30 min, and rinsed with distilled water.

    • Thermally responsive membrane-based microbiological sensing component for early detection of membrane biofouling

      2011, Desalination
      Citation Excerpt :

      This peak remained after reaction with the antibody, which suggests EDC presence. A small peak (4) appeared at 3290 cm−1 on antibody-EDC-HPC spectra, which was the –OH stretching band [24]. Another small peak (3) appeared at 2754 cm−1 on the antibody-EDC-HPC spectra, which does not exist on the time 0 spectra.

    View all citing articles on Scopus
    View full text