Heart rate monitoring and therapeutic devices: A wavelet transform based approach for the modeling and classification of congestive heart failure

https://doi.org/10.1016/j.isatra.2018.05.003Get rights and content

Highlights

  • Peak detection and data compression of ECG signal are studied using adaptive slope prediction and LZMA compression.

  • Biorthogonal wavelet transform based technique for the modelling and characterization of congestive heart failure.

  • The proposed methodology achieves the highest signal to noise ratio, and lowest root mean square error.

  • Comparison of proposed method is made with existing reported techniques.

  • The use of LZMA data compression of ECG data achieves a high compression ratio.

Abstract

Heart rate monitoring and therapeutic devices include real-time sensing capabilities reflecting the state of the heart. Current circuitry can be interpreted as a cardiac electrical signal compression algorithm representing the time signal information into a single event description of the cardiac activity. It is observed that some detection techniques developed for ECG signal detection like artificial neural network, genetic algorithm, Hilbert transform, hidden Markov model are some sophisticated algorithms which provide suitable results but their implementation on a silicon chip is very complicated. Due to less complexity and high performance, wavelet transform based approaches are widely used. In this paper, after a thorough analysis of various wavelet transforms, it is found that Biorthogonal wavelet transform is best suited to detect ECG signal's QRS complex. The main steps involved in ECG detection process consist of de-noising and locating different ECG peaks using adaptive slope prediction thresholding. Furthermore, the significant challenges involved in the wireless transmission of ECG data are data conversion and power consumption. As medical regulatory boards demand a lossless compression technique, lossless compression technique with a high bit compression ratio is highly required. Furthermore, in this work, LZMA based ECG data compression technique is proposed. The proposed methodology achieves the highest signal to noise ratio, and lowest root mean square error. Also, the proposed ECG detection technique is capable of distinguishing accurately between healthy, myocardial infarction, congestive heart failure and coronary artery disease patients with a detection accuracy, sensitivity, specificity, and error of 99.92%, 99.94%, 99.92% and 0.0013, respectively. The use of LZMA data compression of ECG data achieves a high compression ratio of 18.84. The advantages and effectiveness of the proposed algorithm are verified by comparing with the existing methods.

Introduction

The global increase in the deaths caused by cardiovascular diseases (CVD) is on a rampage and agencies have cited alarming percentages of such deaths [1]. With more hectic lifestyles, rapidly aging population and globally expanding life expectancy, control of CVD require purposeful and consequential healthcare amenities. This increasing problem can be efficiently dealt with the creation of economic, patient-centric and wearable wireless devices for recording and tracking vital signs. Dedicated measures and devices intercepting early signs of CVD can be a better way off in early preventive, diagnostic test models. The big challenge here is to develop self-effacing, humble, patient-friendly wearable device for reading and monitoring electrocardiogram (ECG) data in continual and uninterrupted manner. The next level challenge for such devices is to be light in weight with extended battery life, which requires a substantial integration and simulation of signals and complex data [2].

The wearable portable device thrives and draws power from wireless transceiver. To increase the efficiency of a wearable heart monitoring device, it is much imperative to decrease or prune the use of transceivers, hence efficaciously lowers the power consumption. Analysis of QRS complex detection and R-R interval estimation as part of ECG signals as shown in Fig. 1, are much advisable and advantageous to be conducted for an ECG sensor. Such analysis facilitates and activates the required transmission when it is adjudged to be of critical importance based on patient's cardiac health, thereby leading to decreased power generated through the system. Additionally, the continuous monitoring of patient's heart thus leads and generates a sizeable and substantial amount of ECG data which requires being accumulated and hosted locally in various formats of memory and data storage. Once reserved appropriately, the data needs further seamless transfer to appropriate channels for meaningful investigation. This series of steps in the data collection, storage, and analysis requires heavy power utilization.

To deal the substantial power requirements of ECG data transmission, efforts are being made to compress the ECG data to minimize the rate at which data is produced for transmission is reduced thus helping in lowering the power requirements of the system. To achieve high compression ratio lossy data compression techniques and procedures are considered, but they have failed to provide required results. The ECG signal reconstructed after lossy data compression results in an ECG signal that contains a sizable amount of noise, due to which crucial diagnostic data gets wasted thus lacking regulatory conformity. For medical applications, the complications in lossy compression techniques used in ECG data compression demand usage of lossless data compression techniques of ECG signals. The world of wearable sensors is experiencing new waves with high-efficiency, decreased power operation and modest convolution in the application. Hence, it is much required to find a better fit and balance between the complexity and compression ratio (CR).

The current trends and medical scenario, have given birth to several QRS complex detection algorithms [3,4,[60], [61], [62]]. The striking feature of all these detections algorithms is reduced power consumption which is an enabler of wearable devices. The research in wearable devices has integrated both unified lossy and lossless data compression techniques together. The research advancements in cardiac health monitoring have made it quantifiable to note the reduction in the sensor power by 2–5 times [5]. It is comprehended that implementation and combination of two distinct hardware setups for QRS complex detection and compression lead to increased system computations and power. Therefore, it is of utmost importance to have a joint QRS complex detection and lossless data compression algorithm.

In the present work, an improved wavelet transform based joint ECG detection, and data compression algorithm applicable for the modeling and characterization of congestive heart failure is proposed. To decide on congestive heart failure, a detailed analysis and characterization of the ECG signal morphology are required. The biorthogonal wavelet transform is used to design wavelet filter banks (WFBs) due to its higher SNR compared to other wavelet transforms and requires less number of coefficients, and its shape resembles the ECG wave. The proposed wavelet filter bank is different from previously designed WFBs. Instead of using conventional low and high pass filter pairs, the proposed decimated WFB architecture consists of a series combination of three lowpass filters realized using wave digital filter realization. The proposed architecture thus considerably reduces the circuit complexity as less number of gates, and less number of clocks with different frequency at each level are required which results in an advantage of lower dynamic power dissipation. Lowpass filters realized using wave digital filter structure reduces the multipliers count by 75% and delay elements count by 80%. In the ECG detection block, an adaptive slope predication-based threshold is employed. Furthermore, Lempel–Ziv–Markov chain algorithm (LZMA) data compression technique is used to compress the ECG data. Finally, the efficiency of the proposed design is quantified regarding signal-to-noise ratio, detection accuracy, percentage root mean square difference and compression ratio.

The rest of the paper is structured as follows. Following the introduction in Section 1, the methodology used to design the proposed work is discussed in Section 2. The detailed description of the results is provided in Section 3, and the results are discussed in detail in Section 4. Finally, Section 5 concludes the paper.

Section snippets

Methodology

Different recorded physiologic signals from Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) arrhythmia database, PTB diagnostic ECG database, from physionet.org [6] are chosen for the analysis of the proposed method. The MIT-BIH arrhythmia database contains 48 different ECG signals recorded from different subjects. The duration of each record is 30:06 min with a frequency of 360 Hz. The collected data is further classified into five types: normal, atrial premature

Experiment results

The proposed design is implemented using Matlab R2017a and tested amongst various ECG signal from different databases, namely, MIT-BIH database, BIDMC congestive heart failure database, PTB diagnostic ECG database, and St.-Petersburg Institute of Cardiological Techniques 12-lead arrhythmia database [63]. The frequency range of raw ECG data taken from these databases lies between 250 Hz and 1000 Hz.

Discussion

The proposed joint ECG detection and data compression technique are evaluated against the robustness to noise, numerical efficiency, and parameter choice, targeting a universal fast and robust heart rate monitoring and therapeutic device. As the ECG signal can get corrupted with various noises, namely, muscle noise, baseline wandering, motion artifacts to name a few, therefore, the designed technique should be robust to these noises. It is evident from Table 6 that the proposed technique

Conclusion

In this work, peak detection and lossless data compression of an ECG signal are studied using adaptive slope prediction thresholding and LZMA compression. The proposed technique is validated using various ECG signal databases. Using the proposed adaptive slope prediction technique, sensitivity, specificity and, overall detection error, respectively, are found to be 99.94% 99.92%, and 0.0013. Further, using LZMA compression technique, a compression ratio of 18.89 is achieved when compared to

Compliance with ethical standards

Conflict of Interest: Author Ashish Kumar declares that he has no conflict of interest. Author Rama Komaragiri declares that he has no conflict of interest. Author Manjeet Kumar declares that he has no conflict of interest.

Ethical approval: This article does not contain any studies with human participants or animals performed by any of the authors.

References (66)

  • M. Cvikl et al.

    FPGA-oriented HW/SW implementation of ECG beat detection and classification algorithm

    Digit Signal Process

    (2010 Jan 1)
  • S.W. Chen et al.

    A real-time QRS detection method based on moving-averaging incorporating with wavelet denoising

    Comput Meth Progr Biomed

    (2006 Jun 1)
  • V. Kumar et al.

    Improved modified AZTEC technique for ECG data compression: effect of length of parabolic filter on reconstructed signal

    Comput Electr Eng

    (2005 Jun 1)
  • S.K. Mukhopadhyay et al.

    An ECG signal compression technique using ASCII character encoding

    Measurement

    (2012 Jul 1)
  • S.K. Mukhopadhyay et al.

    ECG signal compression using ASCII character encoding and transmission via SMS

    Biomed Signal Process Contr

    (2013 Jul 1)
  • M.S. Manikandan et al.

    Wavelet threshold based ECG compression using USZZQ and Huffman coding of DSM

    Biomed Signal Process Contr

    (2006 Oct 1)
  • S.H. Ling et al.

    Non-invasive hypoglycemia monitoring system using extreme learning machine for Type 1 diabetes

    ISA (Instrum Soc Am) Trans

    (2016)
  • S. Jain et al.

    QRS detection using adaptive filters: a comparative study

    ISA (Instrum Soc Am) Trans

    (2017)
  • I.S. Tawfic et al.

    An improved stopping condition guarantee recovery of sparse signal via Subspace Pursuit method

    ISA (Instrum Soc Am) Trans

    (2017)
  • M. Kumar et al.

    Optimal fractional delay-IIR filter design using cuckoo search algorithm

    ISA (Instrum Soc Am) Trans

    (2015 Nov 1)
  • M. Kumar et al.

    Adaptive infinite impulse response system identification using modified-interior search algorithm with Lèvy flight

    ISA Trans

    (2017 Mar 1)
  • World Health Statistics 2017

    (2017)
  • C.J. Deepu et al.

    An ECG-on-chip for wearable cardiac monitoring devices

  • A. Kumar et al.

    Design of high-performance ecg detector for implantable cardiac pacemaker systems using biorthogonal wavelet transform

    Circ Syst Signal Process

    (2018)
  • C.J. Deepu et al.

    3-lead ECG-on-chip with QRS detection and lossless compression for wireless sensors

    IEEE Trans Circ Syst II: Exp Brief

    (2016 Dec)
  • [Online]. Available: https://physionet.org/cgi-bin/atm/ATM. (Accessed on 5th April...
  • G.M. Friesen et al.

    A comparison of the noise sensitivity of nine QRS detection algorithms

    IEEE Trans Biomed Eng

    (1990 Jan)
  • R. Sameni et al.

    A nonlinear Bayesian filtering framework for ECG denoising

    IEEE (Inst Electr Electron Eng) Trans Biomed Eng

    (2007 Dec)
  • A.S. Khaing et al.

    Quantitative investigation of digital filters in electrocardiogram with simulated noises

    Int J Inform. Electron Eng.

    (2011 Nov 1)
  • H.D. Hesar et al.

    ECG denoising using marginalized particle extended Kalman filter with an automatic particle weighting strategy

    IEEE J Biomed Health Inform

    (2017 May)
  • O. Sayadi et al.

    ECG denoising and compression using a modified extended Kalman filter structure

    IEEE (Inst Electr Electron Eng) Trans Biomed Eng

    (2008 Sep)
  • L. Smital et al.

    Adaptive wavelet wiener filtering of ECG signals

    IEEE Trans Biomed Eng

    (2013 Feb)
  • M.A. Unser

    Ten good reasons for using spline wavelets

  • Cited by (56)

    • Adaptive periodic mode decomposition and its application in rolling bearing fault diagnosis

      2021, Mechanical Systems and Signal Processing
      Citation Excerpt :

      Therefore, it is a difficult problem to extract the periodic impulse components accurately [2]. Wavelet transform (WT) is a classical signal decomposition method [3,4,5]. WT mainly decomposes vibration signals into a series of single-component signals with different features through wavelet basis.

    • Stationary wavelet transform based ECG signal denoising method

      2021, ISA Transactions
      Citation Excerpt :

      In the literature, researchers presented various techniques to remove noises from the biological signals. Some of these techniques include highpass filters [7], lowpass filters [8,9], notch filters [10,11], adaptive filters [12,13], empirical mode decomposition (EMD) [14,15], wavelet transform (which mainly includes discrete wavelet transform (DWT) [16–21], stationary wavelet transform (SWT) [4], blind source separation method [22] and Fourier decomposition method (FDM) [23]. A highpass filter is used to remove baseline wandering noises, while the lowpass filter is used to remove powerline interference noises.

    View all citing articles on Scopus
    View full text