Amperometric Biosensors Based on Carbon Paste Electrodes Chemically Modified With Redox-Enzymes
References (55)
- et al.
Enzymatic determination of glucose in a flow system by catalytic oxidation of the nicotinamide coenzyme at a chemically modified electrode
Anal. Chim. Acta
(1985) - et al.
Polyethyleneimine in immobilization of biocatalysts
Enzyme Microb. Technol.
(1991) - et al.
Mediatorless electrocatalytic reduction of hydrogen peroxide at graphite electrodes chemically modified with peroxidases
J. Biotechnol.
(1993) - et al.
Carbon fibre as electrode materials for the construction of peroxidase modified amperometric biosensors
Anal. Chim. Acta
(1993) - et al.
Liquid chromatographic separation and stereo detection of L- and D-amino acids with catalytic reaction detection using immobilized enzymes
J. Pharm. Biomed. Anal.
(1990) - et al.
A carbon paste electrode chemically modified with a phenothiazine polymer derivative and yeast alcohol dehydrogenase for the analysis of ethanol
Biosens. Bioelectron.
(1993) - et al.
Amperometric glucose sensors based on immobilised glucose oxidising enzymes and chemically modified electrodes
Anal. Chim. Acta
(1991) - et al.
Selective detection in flow analysis based on the combination of immobilised enzymes and chemically modified electrodes
Anal. Chim. Acta
(1991) - et al.
Electrocatalytic reduction of hydrogen peroxide via direct electron transfer from pyrolytic graphite electrodes to irreversibly adsorbed cytochrome c peroxidase
J. Electroanal. Chem.
(1989) A chemically modified graphite electrode for electrocatalytic oxidation of reduced nicotinamide adenine dinucleotide based on a phenothiazine derivative, 3-ß-naphthoyl-toluidine Blue O
J. Electroanal. Chem.
(1990)
Amperometric biosensors based on electrocatalytic regeneration of NAD at redox polymer-modified electrodes
Biosens. Bioelectron.g
(1993)
Determination of xylose and glucose in a flow-injection system with PQQ-dependent aldose dehydrogenase
Anal. Chim. Acta
(1993)
Mediated amperometric determination of xylose and glucose with an immobilized aldose dehydrogenase electrode
Biosens. Bioelectron.
(1992)
Amperometric enzyme electrode for the determination of L-glutamate
Talanta
(1991)
A specific enzyme electrode for L-glutamate development and application
Biosensors
(1989)
Bulk modified enzyme electrodes for reagentless detection of peroxides
Bioelectrochem. Bioenerg.
(1991)
High-performance liquid chromatographic detection of L- and D-amino acid by use of immobilized enzyme electrodes as detectors
Anal. Chim. Acta
(1988)
Flow-injection analysis for L-glutamate using immobilized L-glutamate oxidase: Comparison of an enzyme reactor and enzyme electrode
Anal. Chim. Acta
(1990)
Direct electrochemistry of redox proteins
Acc. Chem. Res.
(1988)
Fast interfacial electron transfer between cytochrome c peroxidase and graphite electrodes promoted by aminoglycosides: Novel electroenzymic catalysis of H2O2 reduction
J. Am. Chem. Soc.
(1987)
Towards macromolecular recognition at electrodes: Fast interfacial electron transfer to cytochrome c peroxidase at graphite electrodes is promoted by aminoglycosides
Biochem. Soc. Trans.
(1988)
Chemically modified electrodes in liquid chromatography detection: A review
Talanta
(1990)
Kinetic aspects of the use of modified electrodes and mediators in bioelectrochemistry
Progr. React. Kinet.
(1991)
Reagentless enzyme electrodes for ethanol, lactate, and malate
Anal. Chem.
(1980)
An amperometric glucose electrode based on carbon paste, chemically modified with glucose dehydrogenase, nicotinamide adenine dinucleotide and a phenoxazine mediator, coated with a poly(ester-sulfonic acid) cation-exchanger
Electroanalysis
(1991)
A xylose-oxidizing membrane-bound aldose dehydrogenase of Gluconobacter oxydans ATCC 621
J. Biotechnol.
(1991)
Cited by (0)
Copyright © 1996 Jai Press Inc. Published by Elsevier B.V. All rights reserved.