Volume 71, Issue 4, July–August 2019, Pages 297-302
Indian Heart Journal

Original Article
A prospective study of contrast preservation using ultra-low contrast delivery technique versus standard automated contrast injector system in coronary procedures

https://doi.org/10.1016/j.ihj.2019.09.001Get rights and content
Under a Creative Commons license
open access

Abstract

Background

We aimed to assess the decrease in contrast media volume (CMV) with ultra-low contrast delivery technique (ULCD) developed at our institution versus the usual automated contrast injector system (ACIS) contrast delivery in coronary procedures.

Methods

We analyzed the amount of contrast given in the consecutive 204 patients of the operators who use ULCD technique versus consecutive 200 patients of the other operators who use ACIS without ULCD technique for coronary angiograms and/or percutaneous coronary interventions (PCIs) from May 2017 to July 2018 at our center. We calculated the mean CMV between these groups.

Results

We observed a significant reduction in mean CMV with ULCD technique versus standard ACIS, respectively: angiogram 24.8 ± 15.8 mL (n = 194) vs 42.3 ± 25.1 mL (n = 200) (p < 0.0001); PCI 23.5 ± 19.7 mL (n = 52) vs 48.2 ± 30.8 mL (n = 16) (p < 0.0070); angiogram with ad hoc PCI 53.4 ± 32.1 mL (n = 23) vs 89.7 ± 35.6 mL (n = 16) (p < 0.0024); and overall angiogram and PCI 27.4 ± 20.5 mL (n = 204) vs 44.9 ± 28.0 mL (n = 181) (p < 0.0001).

Conclusion

Our study showed a highly significant reduction in CMV using ULCD technique compared to standard ACIS contrast delivery in coronary invasive procedures. Even in the standard ACIS arm, CMV was significantly lower than values reported in literature, possibly due to operators' bias toward contrast preservation.

Keywords

Contrast media
Contrast-induced nephropathy
Ultra-low contrast delivery
Automated contrast injector system