Background. Artifacts in clinical intensive care monitoring lead to false alarms and complicate later data analysis. Artifacts must be identified and processed to obtain clear information. In this paper, we present a method for detecting artifacts in PCO2 and PO2 physiological monitoring data from preterm infants. Patients and data. Monitored PO2 and PCO2 data (1 value per minute) from 10 preterm infants requiring intensive care were used for these experiments. A domain expert was used to review and confirm the detected artifact. Methods.Three different classes of artifact detectors (i.e., limit-based detectors, deviation-based detectors, and correlation-based detectors) were designed and used. Each identified artifacts from a different perspective. Integrating the individual detectors, we developed a parametric artifact detector, called ArtiDetect. By an exhaustive search in the space of ArtiDetect instances, we successfully discovered an optimal instance, denoted as ArtiDetector. Results. The sensitivity and specificity of ArtiDetector for PO2 artifacts is 95.0% (SD = 4.5%) and 94.2% (SD = 4.5%), respectively. The sensitivity and specificity of ArtiDetector for PCO2 artifacts is 97.2% (SD = 3.6%) and 94.1% (SD = 4.2%), respectively. Moreover, 97.0% and 98.0% of the artifactual episodes in the PO2 and PCO2 channels respectively are confirmed by ArtiDetector. Conclusions. Based on the judgement of the expert, our detection method detects most PO2 and PCO2 artifacts and artifactual episodes in the 10 randomly selected preterm infants. The method makes little use of domain knowledge, and can be easily extended to detect artifacts in other monitoring channels.
Article PDF
Similar content being viewed by others
REFERENCES
Meredith C, Edworthy J. Are there too many alarms in the intensive care unit? An overview of the problems. Int J Adv Nurs 1995; 21: 15–20
Tsien CL, Fackler JC. Poor prognosis for existing monitors in the intensive care unit. Crit Care Med 1997; 25: 614–619
Cao CG, McIntosh N. Empirical study on artifact detec-tion in monitoring data. In Proceedings of the 1998 Annual Symposium of American Medical Informatics Association, 1998; 983
Cunningham S, Symon AG, McIntosh N. The practical management of artifact in computerised physiological Data. Int J ClinMonit Comput 1994; 11: 211–216
Sittig DF, Factor M. Physiological trend detection and artifact rejection: A parallel implementation of a multi-state Kalman filtering algorithm. Int J ComputMeth Prog in Bio 1990; 31: 1–10
Rampil IJ. Intelligent detection of artifact. In: Gravenstein JS, Newbower RS, Ream AK et al., eds. The Automated Anesthesia Record and Alarm System. Boston: Butter-worths, 1987: 175–190
Young WH, Gardner RM, East TD, Turner K. Compu-terized ventilator data selection: Artifact rejection and data reduction. Int J ClinMonit Comput 1994; 14: 165–176
Rheineck-Leyssius AT, Kalkman CJ. Influence of pulse oximeter settings on the frequency of alarms and detection of hypoxemia: Theoretical effects of artifact rejection, alarm delay, averaging, median filtering or a lower setting of the alarm limit. Int J Clin Monit Comput 1998; 14: 151–156
Poets CF, Stebbens VA. Detection of movement artifact in recorded pulse oximeter saturation. Eur J Pediatr 1997; 156: 808–811
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Cao, C., McIntosh, N., Kohane, I.S. et al. Artifact Detection in the PO2 and PCO2 Time Series Monitoring Data from Preterm Infants. J Clin Monit Comput 15, 369–378 (1999). https://doi.org/10.1023/A:1009942832137
Issue Date:
DOI: https://doi.org/10.1023/A:1009942832137