Abstract
A suite of natural matrix reference materials (RMs) were used to assess the quality of analytical results obtained by k 0-instrumental neutron activation analysis (k 0-INAA) at the Jožef Stefan Institute (IJS). Five certified reference materials (CRMs) from the Institute for Reference Materials and Measurements (IRMM), two standard reference materials (SRMs) from the National Institute of Standards and Technology (NIST), three RMs from the International Atomic Energy Agency (IAEA) and one RM from IJS were analyzed. Altogether, results for twenty-four elements in inorganic matrices and twenty-nine elements in organic matrices, obtained by k 0-INAA, were compared to certified values. Results obtained show good agreement with certified or assigned values except for Fe, La, Nd, Sm and U in inorganic matrices, and Ag, Al and Cr in organic matrices.
Similar content being viewed by others
References
F. De Corte, Habilitation Thesis, University of Gent, 1987.
B. SmodiŠ, Mikrochim. Acta, 123 (1996) 303.
P. Robouch, G. Arana, M. Eguskiza, S. PommÉ, N. Etxebarria, J. Radioanal. Nucl. Chem., 245 (2000) 195.
Quantifying Uncertainty in Analytical Measurement, Published by EURACHEM Secretariat, Queens Road, Teddington, Middlesex, TW110LY, United Kingdom, 1995.
S. JovanoviĆ, P. VukotiĆ, B. SmodiŠ, R. JaĆimoviĆ, N. MihaljeviĆ, P. Stegnar, J. Radioanal. Nucl. Chem., 129 (1989) 343.
B. SmodiŠ, R. JaĆimoviĆ, S. JovanoviĆ, P. Stegnar, P. VukotiĆ, Vestn. Slov. Kem. Drus., 35 (1988) 397.
F. De Corte, R. Van Sluijs, A. Simonits, J. KuČera, B. SmodiŠ., A. R. Byrne, A. De Wispelaere, D. Bossus, J. FrÁna, Z. HorÁk, R. JaĆimoviĆ, Fresenius J. Anal. Chem., 370 (2001) 38.
B. Fazekas, G. MolnÁr, T. Belgya, L. Dabolczi, A. Simonits, J. Radioanal. Nucl. Chem., 215 (1997) 271.
HYPERMET-PC V5.0, User.s Manual, Institute of Isotopes, Budapest, Hungary, 1997.
KAYZERO/SOLCOI® for reactor-neutron activation analysis (NAA) using the k 0-standardization method, DSM Research, Geleen, Netherlands, Dec. 1996.
F. De Corte, A. Simonits, J. Radioanal. Nucl. Chem., 133 (1989) 43.
F. De Corte, A. Simonits, F. Bellemans, M. C. Freitas, S. JovanoviĆ, B. SmodiŠ., G. Erdtmann, H. Petri, A. De Vespelaere, J. Radioanal. Nucl. Chem., 169 (1993) 125.
R. JaĆimoviĆ, S. JovanoviĆ, B. SmodiŠ., P. VukotiĆ, P. Stegnar, Vestn. Slov. Kem. Drus., 36 (1989) 35.
B. SmodiŠ., R. JaĆimoviĆ, S. JovanoviĆ, P. Stegnar, Biol. Trace Elem. Res., 26 (1990) 43.
B. SmodiŠ., R. JaĆimoviĆ, P. Stegnar, S. JovanoviĆ, J. Radioanal. Nucl. Chem., 160 (1992) 101.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Jaćimović, R., Smodiš, B., Bučar, T. et al. k0-NAA quality assessment by analysis of different certified reference materials using the KAYZERO/SOLCOI software. Journal of Radioanalytical and Nuclear Chemistry 257, 659–663 (2003). https://doi.org/10.1023/A:1026116916580
Issue Date:
DOI: https://doi.org/10.1023/A:1026116916580