Issue 5, 1998

Organic and inorganic selenium speciation in urine by on-line vesicle mediated high-performance liquid chromotography–focused microwave digestion–hydride generation–inductively coupled plasma mass spectrometry

Abstract

A vesicle mediated high performance liquid chromatographic (HPLC)–microwave digestion (MW)–hydride generation (HG) system coupled on-line with atomic absorption spectrometry (AAS) and inductively coupled plasma mass spectrometry (ICP-MS) has been assessed for selenium species separation and detection. Selenocystine, selenomethionine, selenoethionine, selenourea, SeIV and SeVI are separated by vesicle mediated chromatography prior to on-line selenocompounds microwave digestion with a KBrO3–HBr mixture to generate SeIV continuously, which is finally transformed into SeH2, in a continuous manner with a merging flow of sodium tetrahydroborate(III). Analytical characteristics of this coupling are compared with those obtained coupling HPLC–ICP-MS via conventional nebulisation. Detection limits (DLs) obtained for selenocystine, selenomethionine, selenoethionine, selenite and selenate in spiked human urine, when ICP-MS was used as detector, ranged between 1.0 and 5.3 µg l–1 (51–267 pg), while precision ranged between±3.4 and±8.4%. This continuous system, vesicle mediated HPLC–MW–HG–atomic detection, allows the separation and detection of selenocystine, selenourea, selenomethionine, selenoethionine, selenite and selenate in human urine. The analytical versatility of such coupling (with ICP-MS as the atomic detector) allows basal selenium speciation in urine. Three different normally occurring selenium species in human urine, simply diluted (1+1), have been found. The relative sophistication of the vesicle mediated–HPLC–MW–HG–ICP-MS interface, versus HPLC–ICP-MS via conventional nebulisation, can be justified because of its considerably higher sensitivity for most of the selenocompounds assayed, lower matrix interferences and the possibility of simultaneous interference free 77Se and 78Se monitoring.

Article information

Article type
Paper

J. Anal. At. Spectrom., 1998,13, 423-429

Organic and inorganic selenium speciation in urine by on-line vesicle mediated high-performance liquid chromotography–focused microwave digestion–hydride generation–inductively coupled plasma mass spectrometry

J. M. González Lafuente, M. Dlaska, M. L.fernández Sánchez and A. Sanz-medel, J. Anal. At. Spectrom., 1998, 13, 423 DOI: 10.1039/A707101I

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements