Issue 1225, 1978

Fluorescence properties of metoclopramide and its determination in pharmaceutical dosage forms

Abstract

The native fluorescence characteristics of metoclopramide in various solvents and at different pH values were determined qualitatively and quantitatively. Fluorimetric determinations can be performed directly and are based on an intense emission at 360 nm that occurs when the sample is excited at 310 nm following dilution in pH 2.0 buffer solution to a final concentration up to 6 µg ml–1. The detection limit is 3 × 10–2µg ml–1.

A comparison is made between the fluorescence behaviour of metoclopramide and the structurally analogous procainamide molecule. Finally, metoclopramide has been converted into its monoacetyl derivative at the primary aromatic amine function. Spectral data confirming the structure are reported. Apart from the second-order excitation shoulder at 275 nm, no significant difference concerning fluorescence behaviour, qualitative or quantitative, between the acetyl derivative and the original molecule is established.

Article information

Article type
Paper

Analyst, 1978,103, 359-367

Fluorescence properties of metoclopramide and its determination in pharmaceutical dosage forms

W. Baeyens and P. De Moerloose, Analyst, 1978, 103, 359 DOI: 10.1039/AN9780300359

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.