Evaluation of Sr chemical purification technique for natural geological samples using common cation-exchange and Sr-specific extraction chromatographic resin prior to MC-ICP-MS or TIMS measurement

Abstract

In this paper, sample preparation protocols based on common cation-exchange and Sr-specific extraction chromatographic resin were evaluated and investigated for natural geological samples prior to 87Sr/86Sr ratio measurement using MC-ICP-MS or TIMS. Several CRMs and real geological samples were digested using HF, HNO3 and HClO4 in closed vessels prior to sequential chemical purifications and then Sr isotopic ratios were determined by MC-ICP-MS or TIMS. Because HREEs reside in the Sr fraction when common cation-exhange resin is used, this purification technique is unsuitable prior to MC-ICP-MS analysis, as doubly loaded HREE interfere on Sr masses. We observe an obviously positive relationship between the radiogenic 87Sr/86Sr ratio and the content of HREEs in the Sr fractions, as well as a negative relationship between un-radiogenic 84Sr/86Sr or 84Sr/88Sr ratios and the content of HREEs in the Sr fractions during MC-ICP-MS Sr isotopic measurement. Such effects are insignificant for TIMS measurement, because ionization temperatures are generally lower and can be well controlled during the analyses. In contrast to the traditional Sr purification method (cation exchange resin), Sr-specific extraction chromatographic resin produces high purity Sr fractions, making it feasible for both MC-ICP-MS and TIMS.

Graphical abstract: Evaluation of Sr chemical purification technique for natural geological samples using common cation-exchange and Sr-specific extraction chromatographic resin prior to MC-ICP-MS or TIMS measurement

Article information

Article type
Technical Note
Submitted
17 Nov 2011
Accepted
25 Jan 2012
First published
09 Feb 2012

J. Anal. At. Spectrom., 2012,27, 516-522

Evaluation of Sr chemical purification technique for natural geological samples using common cation-exchange and Sr-specific extraction chromatographic resin prior to MC-ICP-MS or TIMS measurement

Y. Yang, F. Wu, Z. Liu, Z. Chu, L. Xie and J. Yang, J. Anal. At. Spectrom., 2012, 27, 516 DOI: 10.1039/C2JA10333H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements