Abstract
An experimental study has been made of the imaging properties of a three-aperture electron-optical lens system. In general this lens has all three aperture potentials different from each other. An apparatus was constructed to determine the potential of the middle aperture required to maintain a constant image position while the potential of the last aperture (and hence of the image) is varied, the object position and potential being kept constant.