Development and experimental study of the readout ASIC for muon chambers of the CBM experiment

, , , , , , , , and

Published 29 January 2016 © 2016 IOP Publishing Ltd and Sissa Medialab srl
, , Topical Workshop on Electronics for Particle Physics Citation E. Atkin et al 2016 JINST 11 C01084 DOI 10.1088/1748-0221/11/01/C01084

1748-0221/11/01/C01084

Abstract

The measurement results of the front-end ASIC for the GEM detector read-out are presented. The MUCH ASIC v2 was designed and prototyped via Europractice by means of the 0.18 um CMOS MMRF process of UMC (Taiwan). The parameters of the analog channels, including the CSA, fast and slow shapers, discriminators, were measured. The channels provide a sufficient dynamic range of 100 fC, low power consumption of 10 mW per channel and ENC of 1550 el at a 50 pF detector capacitance.

Export citation and abstract BibTeX RIS

10.1088/1748-0221/11/01/C01084