Thermographical Method to Assess the Performance of Magnetic Nanoparticles in Hyperthermia Experiments through Spatiotemporal Temperature Profiles

D.P. Valdés, T.E. Torres, A.C. Moreno Maldonado, G. Urretavizcaya, M.S. Nadal, M. Vasquez Mansilla, R.D. Zysler, G.F. Goya, E. De Biasi, and E. Lima, Jr.
Phys. Rev. Applied 19, 014042 – Published 13 January 2023

Abstract

The evaluation of the specific power absorption of magnetic nanoparticles (MNPs) for magnetic hyperthermia (MH) applications has been performed through either local temperature probing or magnetic measurements so far. Each of these methods has advantages and drawbacks, and the concurrent use of both techniques offers the most reliable results. In this work, we propose an alternative strategy based on thermographic images to obtain two-dimensional temperature maps that allow the determination of the power absorption and other relevant thermodynamic parameters in MH experiments in a noninvasive way. This procedure and analysis are convenient to determine the heating performance of MNPs under the viscous conditions of in vitro and in vivo assays and to follow the time evolution of the temperature spatial distribution in the sample simultaneously. For this purpose, iron-oxide MNPs with 25-nm average diameter are coated with glucose and dispersed into different 8% polyacrylamide gels, which serve as phantoms that emulate intracellular viscosity. Power absorption experiments are performed under ac magnetic fields (H= 32 kA/m; f= 350 kHz) and the temperature evolution of the sample is monitored through a commercial thermographic camera (resolution, 240×180 pixels; temperature accuracy, 2 K). To complement this simple setup, we design a program consisting of a detailed procedure for extracting graphical information from the video frames and obtaining spatiotemporal temperature profiles. The analysis of these profiles allows us to gather information on temperature, energy, power, and heat flux during the MH experiments. This method and analysis allows us to identify spatial inhomogeneities in samples, such as different local MNP density, which is extremely useful for the development of the therapy in vitro and the application in vivo where MNP aggregation is often present.

  • Figure
  • Figure
  • Figure
  • Figure
  • Figure
  • Figure
  • Figure
7 More
  • Received 11 July 2022
  • Revised 9 November 2022
  • Accepted 8 December 2022

DOI:https://doi.org/10.1103/PhysRevApplied.19.014042

© 2023 American Physical Society

Physics Subject Headings (PhySH)

Physics of Living SystemsInterdisciplinary PhysicsCondensed Matter, Materials & Applied Physics

Authors & Affiliations

D.P. Valdés1,2,*, T.E. Torres1,2, A.C. Moreno Maldonado3, G. Urretavizcaya2,4, M.S. Nadal1, M. Vasquez Mansilla1, R.D. Zysler1,2, G.F. Goya3, E. De Biasi1,2, and E. Lima, Jr.1

  • 1Instituto de Nanociencia y Nanotecnología, CNEA-CONICET, Av. Exequiel Bustillo 9500, Bariloche, Argentina
  • 2Instituto Balseiro, Universidad Nacional de Cuyo, Av. Exequiel Bustillo 9500, Bariloche, Argentina
  • 3Departamento de Física de la Materia Condensada, Instituto de Nanociencia y Materiales de Aragón, Universidad de Zaragoza, C/ Mariano Esquillor s/n, Zaragoza, Spain
  • 4Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), CNEA, Centro Atómico Bariloche, Av. Exequiel Bustillo 9500, Bariloche, Argentina

  • *daniela.valdes@ib.edu.ar

Article Text (Subscription Required)

Click to Expand

References (Subscription Required)

Click to Expand
Issue

Vol. 19, Iss. 1 — January 2023

Subject Areas
Reuse & Permissions
Access Options
Author publication services for translation and copyediting assistance advertisement

Authorization Required


×
×

Images

×

Sign up to receive regular email alerts from Physical Review Applied

Log In

Cancel
×

Search


Article Lookup

Paste a citation or DOI

Enter a citation
×